Numerical analysis of the inner flow field of a biocentrifugal blood pump.
MedLine Citation:
PMID:  16734599     Owner:  NLM     Status:  MEDLINE    
Implantable ventricular assist devices have been regarded as a promising instrument in the clinical treatment of patients with severe heart failures. In this article, a three-dimensional model of the Kyoto-NTN magnetically suspended centrifugal blood pump was generated and a computational fluid dynamics solution of the inner flow field of the pump including the static pressure distributions, velocity profiles, and the shear stress distributions of the blood was presented. The results revealed that reverse flow generally occurred in the impeller blade channels during the operation of the pump, due to the imbalance of the flow and the pressure gradient generated in the blade channels. The flow pattern at the exit of the blade channels was varying with its angular positions in the pump. The reverse flow at the exit of the impeller blade channels was found to be closely related with the static pressure distribution in the volute passage. Higher pressure in the volute caused severe backflow from the volute into the blade channels. To clarify the effects of a moving impeller on the blood, shear stresses of the blood in the pump were investigated according to the simulation results. The studies indicated that at the beginning of the splitter plate and the cutwater, the highest shear stress exceeded 700 Pa. At other regions such as the inlet and outlet of the impeller blade channels and some regions in the volute passage, shear stresses were found to be about 200 Pa. These areas are believed to have a high possibility of rendering blood trauma.
Leok Poh Chua; Guoliang Song; Tau Meng Lim; Tongming Zhou
Related Documents :
2597529 - Left ventricular function in patients with centrifugal left ventricular assist device.
16773509 - The use of an indium111 dtpa flow study in the evaluation of a lumbar swelling in a gir...
1252569 - The influence of surface rugosity on haemolysis occurring in tubing.
15497389 - Biostability of thoralon left ventricular assist device blood pumping sacs after long-t...
19770799 - A passively suspended tesla pump left ventricular assist device.
19178439 - Functional and biocompatibility performances of an integrated maglev pump-oxygenator.
24156049 - Evaluation of laser speckle contrast imaging as an intrinsic method to monitor blood br...
15307449 - Microfluidic flow switching design using volume of fluid model.
8988069 - Abnormal desmopressin-induced forearm vasodilatation in patients with heart failure: de...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Artificial organs     Volume:  30     ISSN:  0160-564X     ISO Abbreviation:  Artif Organs     Publication Date:  2006 Jun 
Date Detail:
Created Date:  2006-05-31     Completed Date:  2006-11-01     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  United States    
Other Details:
Languages:  eng     Pagination:  467-77     Citation Subset:  IM    
School of Mechanical and Production Engineering, Nanyang Technological University, Singapore.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Blood Flow Velocity
Equipment Design
Heart-Assist Devices*
Hemorheology / instrumentation*
Models, Theoretical*
Numerical Analysis, Computer-Assisted*
Shear Strength

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Comparison between intermittent and continuous measurement of cardiac output after acute normovolemi...
Next Document:  Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist ...