Document Detail


Novel surgeon-modified hypogastric branch stent graft to preserve pelvic perfusion.
MedLine Citation:
PMID:  20036506     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: We describe the feasibility and early results of a novel approach to preserve pelvic perfusion during endovascular aortic aneurysm repair (EVAR) in patients with aortoiliac aneurysms extending to the iliac bifurcation. METHODS: Three high-risk patients, aged 70+/-7 years, with large aortoiliac aneurysms (mean 6.7+/-0.5 cm) and inadequate distal common iliac artery landing zones were treated with a surgeon-modified hypogastric branch stent graft between June 2007 and July 2008. The modified device was created using a 73 mm iliac stent graft limb with a presewn 6-8 mm polyester side graft. The modified device was resheathed into a 20F sheath, and the side graft was preloaded with a wire and catheter. The resheathed device was introduced to the level of the aortic bifurcation via a 24F peel-away sheath, and using the preloaded catheter, a long wire was snared, establishing through-and-through femoral access. A 12F contralateral femoral sheath was advanced up and over the aortic bifurcation into the presewn side graft. The repair was bridged to the ipsilateral hypogastric artery using a matting self-expandable stent graft and extended distally to the external iliac artery, followed by standard EVAR. All patients were followed clinically and with computed tomography angiography prior to hospital discharge and every 3 months thereafter. RESULTS: Mean procedural time was 172+/-23 min, including 45+/-22 min for device modification. Total fluoroscopy time, contrast load, and radiation dose were 78+/-17 min, 180+/-23 mL, and 3,890+/-1,034 mGy, respectively. The procedure was technically successful in all cases. There were no aneurysm ruptures, deaths, conversions, or complications; and the mean length of hospitalization was 3.5+/-1 days. At a mean follow-up of 9+/-3 months, all branched hypogastric arteries remained patent without endoleak, migration, or loss of device integrity. CONCLUSION: Surgeon-modified hypogastric branch stent grafts to maintain perfusion to one or both hypogastric arteries is feasible and provides an alternative to hypogastric artery exclusion. Long-term follow-up is needed to evaluate stent-graft patency and failure rates.
Authors:
Gustavo S Oderich; Joseph J Ricotta
Related Documents :
11096626 - Novel aortic reconstruction strategies: endovascular aneurysm repair.
21592826 - Endovascular repair of aorto-iliac artery injuries after lumbar-spine surgery.
16623206 - Abdominal aortic aneurysm.
11220466 - Geometric changes in aortic endografts over a 2-year observation period.
23809936 - Endovascular treatment of a left subclavian pseudoaneurysm induced by ingestion of a fo...
25433566 - Myh11(r247c/r247c) mutations increase thoracic aorta vulnerability to intramural damage...
Publication Detail:
Type:  Case Reports; Journal Article     Date:  2009-12-29
Journal Detail:
Title:  Annals of vascular surgery     Volume:  24     ISSN:  1615-5947     ISO Abbreviation:  Ann Vasc Surg     Publication Date:  2010 Feb 
Date Detail:
Created Date:  2010-02-09     Completed Date:  2010-04-22     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8703941     Medline TA:  Ann Vasc Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  278-86     Citation Subset:  IM    
Copyright Information:
Copyright 2010. Published by Elsevier Inc.
Affiliation:
Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN 55905, USA. oderich.gustavo@mayo.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Aortic Aneurysm / complications,  radiography,  surgery*
Aortography / methods
Blood Vessel Prosthesis*
Blood Vessel Prosthesis Implantation / adverse effects,  instrumentation*
Feasibility Studies
Humans
Iliac Aneurysm / complications,  radiography,  surgery*
Ischemia / etiology,  physiopathology,  prevention & control*
Length of Stay
Male
Pelvis / blood supply*
Polyesters
Prosthesis Design
Regional Blood Flow
Stents*
Time Factors
Tomography, X-Ray Computed
Treatment Outcome
Chemical
Reg. No./Substance:
0/Polyesters