Abstract/OtherAbstract:
A one-channel low temperature superconductor superconducting quantum interference device system comprising a second-order axial gradiometer with a sensing area of 10 mm × 190 mm was developed. The gradiometer was mounted in a liquid-helium dewar (450-mm diameter; 975-mm length), with a gap of 12 mm between the pickup coil and the dewar-tail surface. The magnetic field sensitivity was measured to be 16 fT∕Hz(1∕2) in the white noise regime above 2 Hz. The system was used to measure stainless steel particles of different sizes passing through the sensing area. A 100-μm diameter SUS304 particle was readily detected passing at different positions underneath the large pickup coil by measuring its 1.3-pT magnetic field. Thus, the system was shown to be applicable to quality control of lamination sheet products such as lithium ion batteries.
Authors:
Akihiko Kandori; Kuniomi Ogata; Ryuzo Kawabata; Sayaka Tanimoto; Yusuke Seki
Related Documents :
662693 - Light scattering measurements supporting helical structures for chromatin in solution.
12165253 - Tagging of the magnetization with the transition zones of 360 degrees rotations generat...
16090353 - Predator-prey cycles from resonant amplification of demographic stochasticity.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Review of scientific instruments     Volume:  83     ISSN:  1089-7623     ISO Abbreviation:  Rev Sci Instrum     Publication Date:  2012 Jul 
Date Detail:
Created Date:  2012-08-02     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0405571     Medline TA:  Rev Sci Instrum     Country:  United States    
Other Details:
Languages:  eng     Pagination:  076108     Citation Subset:  IM    
Affiliation:
Central Research Laboratory, Hitachi, Ltd., 1-280 Higashi-Koigakubo, Kokubunji-shi, Tokyo 185-8601, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Note: Grazing incidence small and wide angle x-ray scattering combined with imaging ellipsometry.
Next Document:  Adiponectin is an independent predictor of tissue plasminogen activator levels in patients under hae...