Document Detail


Noninvasive vascular elastography using plane-wave and sparse-array imaging.
MedLine Citation:
PMID:  23357907     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Stroke may occur when an atherosclerotic plaque ruptures in the carotid artery. Noninvasive vascular elastography (NIVE) visualizes the strain distribution within the carotid artery, which is related to its mechanical properties that govern plaque rupture. Strain elastograms obtained from the transverse plane of the carotid artery are difficult to interpret, because strain is estimated in Cartesian coordinates. Sparsearray (SA) elastography overcomes this problem by transforming shear and normal strain to polar coordinates. However, the SA's transmit power may be too weak to produce useful elastograms in the clinical setting. Consequently, we are exploring other imaging methods to solve this potential problem. This study evaluated the quality of elastograms produced with SA imaging, plane-wave (PW) imaging, and compounded-plane-wave (CPW) imaging. We performed studies on simulated and physical vessel phantoms, and the carotid artery of a healthy volunteer. All echo imaging was performed with a linear transducer array that contained 128 elements, operating at 5 MHz. In SA imaging, 7 elements were fired during transmission, but all 128 elements were active during reception. In PW imaging, all 128 elements were active during both transmission and reception. We created CPW images by steering the acoustic beam within the range of -15° to 15° in increments of 5°. SA radial and circumferential strain elastograms were comparable to those produced using PW and CPW imaging. Additionally, side-lobe levels incurred during SA imaging were 20 dB lower than those produced during PW imaging, and 10 dB lower than those computed using CPW imaging. Overall, SA imaging performs well in vivo; therefore, we plan to improve the technique and perform preclinical studies.
Authors:
Sanghamithra Korukonda; Rohit Nayak; Nancy Carson; Giovanni Schifitto; Vikram Dogra; Marvin Doyley
Related Documents :
19420417 - Optimization of rb-82 pet acquisition and reconstruction protocols for myocardial perfu...
2338967 - Regional indices of relative hepatic arterial perfusion from dynamic liver scintigraphy...
7586867 - Quantitative comparison of prone and supine myocardial spect mibi images.
842457 - Technetium-99m stannous pyrophosphate scintigrams in normal subjects, patients with exe...
22483807 - Technetium-99m sestamibi imaging: are the results dependent on the reviewer?
19306507 - Label-free molecular imaging of living cells.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  IEEE transactions on ultrasonics, ferroelectrics, and frequency control     Volume:  60     ISSN:  1525-8955     ISO Abbreviation:  IEEE Trans Ultrason Ferroelectr Freq Control     Publication Date:  2013 Feb 
Date Detail:
Created Date:  2013-01-29     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9882735     Medline TA:  IEEE Trans Ultrason Ferroelectr Freq Control     Country:  United States    
Other Details:
Languages:  eng     Pagination:  332-42     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Fine mapping of tissue properties on excised samples of melanoma and skin without the need for histo...
Next Document:  Time-of-flight measurement techniques for airborne ultrasonic ranging.