Document Detail


Noninvasive monitoring of respiratory volume. Experimental evaluation of a breath monitoring device.
MedLine Citation:
PMID:  8346778     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The authors studied the accuracy of the noninvasive breath monitor (Voltek Enterprise, Willowdale, Ontario, Canada) in predicting the tidal volumes in five healthy human volunteers. The signals of the breath monitor were compared with the volumes estimated by a calibrated pneumotachograph. The results show that the breath monitor is considerably accurate and can be accepted as a reliable device for clinical applications.
Authors:
H M Amin; M Cigada; W E Fordyce; E M Camporesi
Related Documents :
17869978 - Patient-ventilator synchrony during pressure-targeted versus flow-targeted small tidal ...
23390358 - Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penet...
4003928 - Inspiratory force reserve of the respiratory muscles in children with chronic obstructi...
16129818 - Slow breathing improves arterial baroreflex sensitivity and decreases blood pressure in...
2805298 - Intraventricular plus intra-aortic balloon pumping during intractable cardiac arrest.
24161928 - Human or monitor feedback to improve mask ventilation during simulated neonatal cardiop...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Anaesthesia     Volume:  48     ISSN:  0003-2409     ISO Abbreviation:  Anaesthesia     Publication Date:  1993 Jul 
Date Detail:
Created Date:  1993-09-08     Completed Date:  1993-09-08     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  0370524     Medline TA:  Anaesthesia     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  608-10     Citation Subset:  AIM; IM    
Affiliation:
Department of Anesthesiology, SUNY, Health Science Center, Syracuse 13210.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Evaluation Studies as Topic
Humans
Lung Volume Measurements
Monitoring, Physiologic / instrumentation
Respiration / physiology*
Tidal Volume
Comments/Corrections
Comment In:
Anaesthesia. 1994 Jun;49(6):552   [PMID:  8068099 ]
Anaesthesia. 1994 Jan;49(1):76-7   [PMID:  8311221 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The genius infrared tympanic thermometer. An evaluation for clinical use.
Next Document:  The Finapres 2300e finger cuff. The influence of cuff application on the accuracy of blood pressure ...