Abstract/OtherAbstract:
Monitoring of continuous blood pressure and cardiac output is important to prevent hypoperfusion and to guide fluid administration, but only few patients receive such monitoring due to the invasive nature of most of the methods presently available. Noninvasive blood pressure can be determined continuously using finger cuff technology and cardiac output is easily obtained using a pulse contour method. In this way completely noninvasive continuous blood pressure and cardiac output are available for clinical use in all patients that would otherwise not be monitored. Developments and state of art in hemodynamic monitoring are reviewed here, with a focus on noninvasive continuous hemodynamic monitoring form the finger.
Authors:
Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Publication Detail:
Type:  Journal Article; Review     Date:  2012-06-14
Journal Detail:
Title:  Journal of clinical monitoring and computing     Volume:  26     ISSN:  1573-2614     ISO Abbreviation:  J Clin Monit Comput     Publication Date:  2012 Aug 
Date Detail:
Created Date:  2012-07-09     Completed Date:  2012-11-27     Revised Date:  2013-07-12    
Medline Journal Info:
Nlm Unique ID:  9806357     Medline TA:  J Clin Monit Comput     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  267-78     Citation Subset:  IM    
Affiliation:
Laboratory for Clinical Cardiovascular Physiology, AMC Heart Failure Research Center, Amsterdam, The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Pressure Determination / methods*,  trends*
Blood Volume Determination / methods*,  trends*
Cardiac Output*
Humans
Monitoring, Ambulatory / methods*,  trends*
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): J Clin Monit Comput
Journal ID (iso-abbrev): J Clin Monit Comput
ISSN: 1387-1307
ISSN: 1573-2614
Publisher: Springer Netherlands, Dordrecht
Article Information
Download PDF
© The Author(s) 2012
Received Day: 2 Month: 10 Year: 2011
Accepted Day: 30 Month: 5 Year: 2012
Electronic publication date: Day: 14 Month: 6 Year: 2012
pmc-release publication date: Day: 14 Month: 6 Year: 2012
Print publication date: Month: 8 Year: 2012
Volume: 26 Issue: 4
First Page: 267 Last Page: 278
ID: 3391359
PubMed Id: 22695821
Publisher Id: 9375
DOI: 10.1007/s10877-012-9375-8

Noninvasive continuous hemodynamic monitoring
Jasper Truijen1
Johannes J. van Lieshout123
Wilbert A. Wesselink4
Berend E. Westerhof14 Address: +31-20-7512410 +31-20-7512419 berend.westerhof@bmeye.com
1Laboratory for Clinical Cardiovascular Physiology, AMC Heart Failure Research Center, Amsterdam, The Netherlands
2Acute Admissions Unit, Department of Internal Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
3School of Biomedical Sciences, University of Nottingham Medical School, Queen’s Medical Centre, Nottingham, UK
4Clinical Team, BMEYE BV, Centerpoint 1, 4th floor, Hoogoorddreef 60, 1101 BE Amsterdam, The Netherlands

Introduction

The primary evaluation of the hemodynamic condition is done by assessing heart rate (HR) and mean blood pressure (BP) as a surrogate of tissue perfusion. When these parameters change rapidly, a single measurement conveys insufficient information, making continuous measurement desirable [1]. For continuous measurement of BP, cannulation of an artery is the primary approach. However, noninvasive and continuous monitoring of BP has several advantages, particularly if intra-arterial measurement of BP is not warranted while intermittent measurements do not have the required time resolution [2]. Finger cuff technology can provide such continuous and noninvasive monitoring of BP and other hemodynamics parameters.

Although giving vital information, BP and HR due to their regulated nature frequently do not respond to substantial changes in intravascular volume, e.g. fluid administration or blood loss. Age and pre-existing cardiovascular morbidity complicate interpretation of these parameters further [39]. In supine adults hypotension and tachycardia are frequently absent even after blood loss of more than 1 l [38, 10, 11]. Therefore, fluid administration to optimize cardiac preload guided by BP is not straightforward. In contrast, cardiac output (CO) and especially cardiac stroke volume (SV) are sensitive to deviations in preload [7, 8]. Also, when arterial pressure is being restored by administering sympathomimetic drugs, it is at the expense of regional flow possibly including that to the brain [12]. Moreover, there is growing evidence that a patient’s cumulative fluid balance as well as strategy to guide fluid administration have an impact on patient morbidity and hospital stay. This has stimulated the development of methods that immediately detect changes in cardiac preload and output. With techniques like trans-esophageal and thoracic echocardiography or Doppler [13, 14], arterial pulse contour analysis [1518] and determination of CO by lithium kinetics [19], several alternatives to the traditional indicator dilution and pulmonary artery catheterization techniques [2022] have become available. These alternatives facilitate continuous and even noninvasive evaluation of volume treatment of patients [23]. Many continuous CO monitoring devices are called “minimally invasive” since they use arterial access that is already present for monitoring of BP or blood gas analysis. Nonetheless, the use of these devices is restricted to patients having such access. Recently, several completely noninvasive devices measuring continuous BP or CO were introduced for clinical use. The Nexfin® (BMEYE B.V. Amsterdam, the Netherlands) allows hemodynamic monitoring with both BP and CO continuously available in patients without an arterial line. Continuous BP is measured with a cuff around a finger and a pulse contour method calculates beat-to-beat CO. This review summarizes past and present developments in BP and CO measurement with a focus on continuous noninvasive finger cuff technology and its clinical applications.


Overview of methods for measurement of blood pressure

The first quantitative measurements of blood pressure were performed in animals by Hales in 1733 [24, 25]. Early reports of intra-arterial pressure measurement in the human are from 1912, when Bleichröder [26] cannulated his own radial artery. It is unlikely that he recorded his BP although it would have been possible at that time: Frank developed accurate and fast manometers that could measure pulsatile pressure in 1903 [27]. Invasive measurement of BP was confined to the physiology labs for quite some time [28, 29]. However in the 1950s and 1960s, with the development of refined insertion techniques [30] and Teflon catheters it became standard clinical practice. High fidelity catheter-tip manometers, such as used to measure pressure gradients across a coronary stenosis, were introduced by Murgo and Millar in 1972 [31]. Table 1 gives an overview of BP methods.

Practical noninvasive (intermittent) BP measurement became possible when Riva-Rocci presented his air-inflatable arm cuff connected to a manometer in 1896 [32, 33]. By deflating the cuff and feeling for the pulse, systolic BP could be determined. In 1905 Korotkoff [34, 35] advanced the technique further with the auscultatory method making it possible to determine diastolic pressure as well. In 1903 Cushing recommended BP monitoring using the Riva-Rocci sphygmomanometer for patients under general anesthesia [36]. Nowadays, automated assessment of BP with oscillometric devices is commonly used. These devices determine BP by analyzing the oscillations measured in the cuff-pressure. The pressure in the cuff is first brought above systolic pressure and then deflated to below diastolic pressure. Oscillations are largest when cuff pressure equals mean arterial pressure. Proprietary algorithms determine systolic and diastolic values from the oscillations. Oscillometers may be inaccurate [37], and provided values that are frequently lower than direct BP measurements in critically ill patients, [38, 39] whereas detection of large BP changes is unreliable [40]. Due to its intermittent nature hyper- and hypotensive periods may be missed [2].

“Semi-continuous noninvasive methods” based on radial arterial tonometry require an additional arm cuff to calibrate arterial pressure [4143]. The use of these devices may become problematic under conditions with significant patient motion or surgical manipulation of the limbs [43, 44]. However, tonometry devices have contributed greatly to the knowledge of the relation between the pressure wave shape and cardiovascular function [45, 46].


Noninvasive continuous measurement of blood pressure

Continuous noninvasive measurement of BP is possible using finger cuff technology. The first generation using this technology was introduced with the Finapres™ device developed by Wesseling et al. [47] in the early 1980s. This technology is based on the volume-clamp method invented by the Czech physiologist Jan Peňáz [4749]. The diameter of a finger artery under a cuff is “clamped” i.e. kept at a constant diameter in the presence of the changes in arterial pressure during each heart beat. Changes in diameter are measured by means of an infrared photo-plethysmograph built into the finger cuff. The finger cuff keeps the diameter of the underlying arteries constant by dynamically applying a counter-pressure throughout the cardiac cycle. When, for instance, during systole an increase in arterial volume is detected by the plethysmograph, the cuff pressure is immediately increased by a rapid pressure servo-controller system to prevent the volume change [17]. An artery could be clamped at any volume between collapsed and fully extended, but in either case the vessel wall will bear part of the pressure. Only when the artery is kept at its “unloaded” volume, there is no tension in the wall and internal pressure equals external pressure. Defining the correct unloaded volume of a finger artery is not straightforward. Moreover, the unloaded volume of an artery has to be established regularly since it is a function of arterial wall smooth muscle stress and tone. At zero transmural pressure the artery is not collapsed but retains approximately 1/3 or 1/2 of its maximal volume. The unloaded volume is also close to the volume it would have at a mean pressure where the amplitude of the pulsations in the plethysmogram are largest. The unloaded volume can be established by “Physiocal®”, developed by Wesseling et al. Physiocal analyzes the curvature and sharpness of the plethysmogram during short periods of steady cuff pressure levels [49]. A set of criteria allows determining whether the volume is precisely at a level that holds the optimum between the slightly too much collapsed and slightly too much extended volumes. The analysis is automatically repeated regularly during measurement, to follow changing physiological states of the vasculature. Owing to Physiocal, calibrated recordings of the entire finger arterial pressure wave are obtained [17]. Generally, an interval between Physiocal calibrations of more than 30 beats is accepted as a criterion for a reliable measurement. Pressure values are typically available within approximately 1 min after starting the measurement. While the Finapres and its successors use Physiocal, the CNAP device (CNSystems Medizintechnik AG, Graz, Austria) uses ‘interlocking control loops’ for volume clamping called the VERIFI algorithm. However, frequent calibration with an upper arm cuff is still needed [50].

The Finapres device showed the arterial pressure as measured at the finger. However, since the brachial site is the clinical standard for noninvasive BP measurement later devices such as the Finometer (FMS, Amsterdam, the Netherlands) and the Nexfin (BMEYE, Amsterdam, the Netherlands) show the brachial pressure reconstructed from the finger pressure. Reconstruction reverses the physiological waveform transformation that waves experience while travelling through the arterial system (see Fig. 1). The progressively narrowing arteries cause backwards reflection of the pressure waves, resulting in a more peaked waveform towards the periphery. Additionally, in the smaller arteries, the resistance starts to play a role and pressure levels become affected. The change in waveform from the central to the peripheral arteries is largely predictable [5153]. The waveform transformation along the arm can be mathematically described and this description can be used to reverse the transformation [54, 55]. The pressure drop due to resistance to flow in the smaller arteries can be compensated by application of a level correction formula. This population based formula determines a pressure drop based on systolic and diastolic values [51]. The combination of these two methods reconstructs brachial artery pressures from finger arterial pressures. An alternative is used in the CNAP device that displays a finger pressure wave that is fitted to systolic and diastolic pressures from upper arm cuff measurements.

Both the Finometer and the Nexfin use a system that automatically corrects for hydrostatic differences in pressure when the hand is not at heart level. The “finger side” of the heart reference system is fixed next to the finger on which the cuff is applied and the “heart side” at right atrial level. The hydrostatic difference is measured and the recordings are continuously corrected to give BP at heart level. The CNAP device uses repeated upper arm cuff measurements to compensate for hydrostatic pressure differences.


Validation of noninvasive continuous measurement of blood pressure

Tracking of changes in BP was already considered good in earlier devices using the finger cuff technology [56]. With the physiological waveform transformation absolute values reconstructed from finger arterial pressures are comparable with (non-) invasively measured brachial or radial pressures [5759]. Measurements with the Nexfin are performed without the need for an external calibration whereas other devices using finger cuff technology such as the Finometer [17, 60] and the CNAP require extra measurements with an upper arm cuff [61]. A recent overview of noninvasive BP monitors and clinical validation studies focused specifically on the need for calibration by a separate method [62].

The BP measurement with the latest generation finger cuff technology device, the Nexfin, was validated against both invasive and noninvasive methods [59, 63, 64]. From a comparison against an auscultatory BP measurement (Riva-Rocci/Korotkoff) in 104 subjects it was concluded that Nexfin provides accurate measurement of BP with good within-subject precision [59]. Validation against invasive radial pressure was performed in fifty patients during coronary artery bypass grafting [64]. Within-patient analyses showed excellent correlations between the noninvasive and invasive pressures and good within subject precisions over wide ranges of pressure changes. Moreover, bias and precision, defined as group average and standard deviation of the differences, were within AAMI criteria [65]. No relation was found between the differences and mean arterial pressure or HR, indicating that the reconstruction methodology performs well in a wide range of hemodynamic states. It was concluded that noninvasively measured blood pressure could follow changes in pressure and provided values comparable to invasive monitoring.

The Nexfin has also been evaluated in an emergency care setting where the authors concluded that continuous BP and HR measured by the Nexfin device showed reasonable agreement when compared with the intermittent values obtained by automated ED equipment [66]. However, they also suggested that theoretically, noninvasive and continuous monitoring of the BP and HR might better reflect underlying hemodynamics than these same measurements obtained intermittently and, thus, could be important in patient management [66].


Overview of methods for measurement of cardiac output

Various methods to measure CO are being used and can be characterized by their invasiveness or their ability to measure continuously. Table 1 gives an overview of CO methods. One of the first methods to determine flow was proposed by Fick [67], and uses the relation between the rate of uptake of oxygen in an organ and the difference of oxygen concentrations over that organ. Therefore, to measure CO (total flow in the body), arterial and mixed venous oxygen concentrations as well as oxygen consumption need to be sampled. Frank, also known for the Frank-Starling law of the heart, developed the 2-element Windkessel model to determine CO [68]. The two elements of this model are total arterial compliance and systemic vascular resistance. After total arterial compliance was estimated by a pulse wave velocity measurement, systemic vascular resistance could be determined from the diastolic decay of the pressure curve. Using Ohm’s law, CO could then be calculated by dividing mean arterial pressure by this resistance. This method can be seen as a very early pulse contour method, in which the shape of the pressure wave is analyzed to obtain CO.

Indicator dilution techniques use the Stewart-Hamilton [69] equation to describe the rate at which an indicator, injected into the blood stream, is diluted. CO is calculated from the quantity of injected indicator and the area under the Stewart-Hamilton curve measured downstream. The indicator usually is a dye or a thermal marker, and is injected into a vein and following passage through the heart subsequently sampled from an artery. For the thermodilution technique iced glucose is injected in the right atrium and the temperature downstream in the pulmonary artery is sampled with the Swan-Ganz catheter [70]. To obtain a reliable estimation with these techniques CO should remain constant for at least the duration of a single measurement. However, HR, SV and BP may change rapidly and this has resulted in the practice to perform several estimations of CO, and even sometimes in elimination of outliers from a series of consecutive thermodilution estimates, both indicating that the requirement of stability is usually not met.

Determination of CO with the thermodilution method is in general restricted to the critically ill patients or patients at high risk associated with an intervention or with serious comorbidities. The use of intermittent estimation of CO by thermodilution is decreasing [2022] owing to the invasive nature of pulmonary artery catheterization. Besides the requirement to be less invasive, it may also be necessary to measure hemodynamic changes with short time intervals. Hereto, monitors need to provide a continuous measure of CO, usually based on analysis of the arterial BP curve (“pulse contour” methods).

In their publication of 1904 Erlanger and Hooker determined cardiac SV from characteristics of the arterial pressure pulse [71]. Pulse contour methods are based on solid physical principles, less solid physiological models, and involve substantial computations [72]. Until recently, pulse contour methods analyzed the arterial pulse wave from an intra-arterial catheter, initially in place for BP monitoring or sampling for blood gas analysis. Several minimally invasive techniques have become available that provide continuous CO measurement [73] operating either with or without an additional (invasive, intermittent) calibration. The LiDCO® system applies a bolus indicator dilution method for CO measurement using lithium chloride as an indicator. Detection of the indicator in arterial blood through a lithium-sensitive electrode produces a lithium concentration–time curve [19]. The produced CO estimate is used to calibrate a pulse contour-derived SV. The PiCCO® system also utilizes pulse contour analysis of intra-arterial BP for continuous CO monitoring, whereas transpulmonary thermodilution is used for calibration [74]. Although still invasive to some extent an advantage of these techniques over conventional thermodilution is that pulmonary artery catheterization is not required. The FloTrac/Vigileo™ system also uses an intra-arterial pressure waveform based pulse contour analysis [7577], but without the need to calibrate.

In general, calibration may improve the accuracy of the absolute values, but is not essential as long as changes in CO are accurately tracked. Continuous tracking is necessary to assess the response to a relatively fast hemodynamic change, such as a fluid challenge or passive leg-raising. Responding to the challenge with a certain increase in CO indicates that the patient is fluid responsive and thus may benefit from receiving additional fluid [7, 9, 78]. A recent meta-analysis comprehensively reviews current minimally invasive CO techniques [79].


Noninvasive continuous measurement of cardiac output

Noninvasive and (semi-)continuous tracking of changes in SV can be accomplished by thoracic electrical impedance [8082], ultrasound [14, 83] and by pulse contour analysis [8488]. Pitfalls of the first method include electrode placement, motion artifacts, validity of the applied equations, and calibration [89, 90]. Doppler ultrasound measurement of aortic blood velocity combined with echocardiographic estimation of the aortic root cross-sectional area yields SV, although semi-continuous at best. The application of the semi-invasive trans-esophageal approach is limited to anesthetized patients. For a transthoracic approach the Doppler probe has to be held over the root of the aorta requiring a skilled operator and constancy of probe angle to minimize bias [83]. Nonetheless, esophageal Doppler has been shown to give positive results in goal-directed therapy [9193].

In order to determine beat-to-beat SV and CO from noninvasive continuous BP from the finger a pulse contour method based on a physiological model of the circulation is used. In the early 1970s Wesseling developed the cZ pulse contour method making use of the systolic part of the pressure curve (pulsatile systolic area, PSA, see Fig. 2). This cZ method used a constant impedance Z to calculate the SV from the PSA. An empirical formula incorporating patient age, HR and mean arterial pressure was used to dynamically correct the impedance Z (hence the name cZ for corrected impedance) for changes in the hemodynamic status. Tracking of SV changes was reliable, but calibration of Z with a reference method was necessary for correct absolute values. Subsequent to the cZ method, Wesseling et al. developed a method using a 3-element Windkessel description of aortic input impedance. By adding a third element to Frank’s 2-element Windkessel, Westerhof et al. [94, 95] substantially improved the modeling of the pressure-flow relation [96]. The third element, the characteristic impedance Zc represents the impedance that the ventricle encounters during ejection. Its value is determined by the interaction of the capacity of the proximal aorta to store volume (thus proximal compliance C) and the blood mass that needs to be accelerated (inertance L). Zc is equal to the square root of L/C. Windkessel compliance Cw is equal to the sum of the compliances of all arteries, mainly the ascending and descending aorta, and it represents the ability to elastically store the stroke volume ejected by the heart. Peripheral resistance Rp equals the sum of all resistances of small arteries and arterioles, representing the resistance to the flow of blood. In Wesseling’s Modelfow method a Windkessel model is used in which Zc and Cw are nonlinear functions of pressure, age, gender, height and weight [97] assuring better absolute CO values and tracking over a wider range of pressures [98]. Using pressure as input a flow curve could be calculated [18, 99, 100]. Subsequent integration of the flow curve yielded SV.

Nexfin CO-trek is a model implemented in the Nexfin that calculates beat-to-beat SV by dividing the area under the systolic part of the reconstructed brachial artery pressure curve by the aortic input impedance (Zin, Fig. 2). Zin is determined from a 3-element Windkessel model [94, 96] with nonlinear descriptions for the parameters as proposed by Wesseling. Values for SV become instantaneously available with the onset of the BP measurement. Using the described physiological models for pressure reconstruction and input impedance, Nexfin CO-trek was internally evaluated on data including invasive and noninvasive finger arterial pressures together with thermodilution CO data obtained during cardiac surgery [98, 99], from healthy subjects experiencing progressive central hypovolemia induced by passive head-up tilt [15], and from critically-ill patients with arterial hypotension due to severe septic shock and treated with catecholamines [16]. Thermodilution CO in these trials was determined with quadruple respiratory phase controlled thermodilution estimates [101]. A specific objective for the development of Nexfin CO-trek was that noninvasive arterial pressure should be employed as input.


Validation of noninvasive continuous measurement of cardiac output

Thoracic electrical impedance and ultrasound measurement of CO have been extensively described in the literature. Raaijmakers concluded that “impedance CO might be useful for trend analysis” [102]. Coats concluded that “Doppler methods are safe, fairly reproducible and reasonably accurate” [103]. It should be noted that, although ultrasound is often used to assess fluid responsiveness, the change in aortic diameter may give rise to substantial errors when not accounted for [104].

In a recent study both noninvasive finger arterial pressure and intra-arterial pressure input were used as input to two validate methods: Nexfin CO-trek and Modelflow. Awake post-coronary artery bypass surgery patients with a pulmonary artery thermodilution-based estimate of CO serving as a reference were included [58]. Measurements were done with patients in supine and sitting position. It was found that Nexfin CO-trek readings were comparable to thermodilution CO, with intra-arterial pressure as well as with noninvasive finger arterial pressure as input. The earlier Modelflow CO-method, developed to be used with invasively measured pressures, performed less well on noninvasive measured BP [58].

Sokolski et al. examined 25 ICU patients with advanced heart failure to compare CO measurements using the pulmonary artery catheter thermodilution method and using the Nexfin [105]. The reported bias and standard deviation were 0.1 and 0.4 l/min, respectively. These results are promising, especially considering the fact that the population included 13 patients with atrial fibrillation and 13 patients with decompensated heart failure. The authors therefore conclude that the Nexfin could be applied in clinical practice for patients with advanced HF.

Broch et al. concluded that “the Nexfin is a reliable method of measuring cardiac output during and after cardiac surgery” [106]. Compared with trans-cardiopulmonary thermodilution, the mean bias of Nexfin was −0.1 (95 % limits of agreement −0.6 to +0.5, percentage error 23 %) and −0.1 (−0.8 to +0.6, 26 %) l min−1 m−2, before and after cardiopulmonary bypass, respectively. These data show that Nexfin gives excellent results without calibration. Further, a good correlation between the two methods was found when passive leg-raise was performed, with R2 = 0.72, p < 0.001 before and R2 = 0.76, p < 0.001 after cardiopulmonary bypass.

Two recent studies further demonstrated the ability of tracking changes in CO. The first compared the changes in SV measured by Nexfin CO-trek with the echo Doppler aortic velocity–time integral as a measure of SV during the optimization of atrioventricular delay in cardiac resynchronization therapy and a good agreement was found [107]. The second study compared, during exercise, the CO of Nexfin CO-trek with inert gas rebreathing method for CO estimation [108]. A good correlation was found and values actually converged for large CO values [109].


Clinical applications of noninvasive continuous hemodynamic monitoring
Anesthesiology

Continuous, totally noninvasive monitoring is possible in groups currently (nearly) unmonitored. Examples include orthopedic surgery in the elderly, abdominal surgery and bariatric surgery. In obese patients upper arm cuffs for BP measurement often do not fit, and thigh cuffs are needed, or a brachial cuff is used on the forearm. While the arms and legs can increase significantly in circumference, fingers do get larger but usually not up to the degree that the finger cuff does not fit.

For surgical patients volume treatment corrects a perioperative volume deficit and attenuates negative influences on the central blood volume (corresponding to the diastolic volume of the heart) caused by, e.g. hemorrhage, repositioning of the patient, anesthesia and ventilation. Interpretation of the heart rate (HR) and arterial pressure responses to a reduced central blood volume is complex. Cardiovascular variables are regulated and affected by influences other than central blood volume, including surgical stress and anesthesia [10]. This makes it unlikely that accurate volume treatment can be based on HR and BP alone. Considering the important contribution of a subnormal central blood volume in circulatory shock, a definition of normovolemia may be derived from individualized goal-directed volume therapy, not only to the patient in shock but also to patients in the perioperative period [8]. Cerebral blood flow and oxygenation become affected with a blood loss corresponding to 30 % of the central blood volume [110] or a blood loss of 1.0–1.5 l [9]. It is becoming clear that monitoring of the circulation allows for intervention well before cerebral blood flow and oxygenation become affected [111]. Fluid therapy guided by cardiac output has been demonstrated to improve perioperative outcome and reduce complications and the length of hospital stay [91, 92, 112]. This goal-directed volume treatment is guided by various techniques that determine cardiac output [92, 93]. The availability of noninvasive and continuous monitoring of SV or CO enables individualization of fluid treatment from fixed-volume to goal-directed volume therapy in a wide range of patients.

Emergency care

Noninvasiveness and ability for quick assessment allows the characterization of hemodynamic profiles of patients in the Emergency Department and following of possible changes. It was demonstrated by Nowak et al. [113] that emergency physicians, when asked whether the CO of their patients was low, normal or high, were right only half of the time. Nonetheless decisions in acutely ill patients are based on such assumptions of the underlying hemodynamic profile [113] with potentially important clinical ramifications.

Cardiology

In cardiac resynchronization therapy, the atrioventricular delay or the inter-ventricular delay can be chosen to optimize SV. In a study comparing noninvasive pulse contour SV with echo Doppler aortic velocity–time integral while optimizing the atrioventricular delay, a good agreement was found and the authors concluded that Nexfin is a promising tool in individual optimization [107].

During invasive electrophysiology procedures, it is common practice to use an intra-arterial line to monitor BP in critical situations of hypotension caused by tachyarrhythmias or by intermittent incremental ventricular temporary pacing till to the maximally tolerated systolic BP fall. During such procedures Nexfin recorded reliable BP waveforms notwithstanding the presence of tachyarrhythmia [114]. The authors stated that continuous noninvasive BP monitoring is feasible in the interventional electrophysiology laboratory and may replace intra-arterial BP in that setting.

Noninvasive BP with finger cuff technology has been used for a long time in the diagnosis and management of syncope [115] and is used in tilt table testing and other autonomic function testing [116]. Nexfin enables continuous cardiovascular evaluation of patients presenting with unexplained syncopal attacks and thus considerably contributed to diagnostic efficacy and accuracy [117]. Also in this field CO is receiving increasing attention [118].


Conclusion and perspective

As indicated by De Waal et al. [119] the ideal CO monitor should be: “reliable, continuous, noninvasive, operator-independent, cost-effective, and should have a fast response time (beat-to-beat).” Noninvasive and continuous determination of CO with the Nexfin is comparable to thermodilution CO, is continuous, truly noninvasive and operator independent. Generally within a minute after start-up, beat-to-beat data on BP, HR, SV and CO become simultaneously available. The only point of contact with the patient is the cuff around a finger. CO monitoring is not routine practice yet due to its often invasive and intermittent nature. Nonetheless, fluid therapy guided by CO has been shown to improve perioperative outcome and to reduce complications as well as length of hospital stay [112, 120]. Noninvasive continuous CO techniques make routine monitoring of CO readily available facilitating easier assessment of fluid-responsiveness and a further application of goal directed fluid therapy.


Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.


References
1.. Woolmer RF. Principles of measurement. Acta Anaesthesiol Scand. 1962;17–21.
2.. Chen G,Chung E,Meng L,Alexander B,Vu T,Rinehart J,Cannesson M. Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic managementJ Clin Monit ComputYear: 20122613314010.1007/s10877-012-9344-222382920
3.. Secher NH,Jacobsen J,Friedman DB,Matzen S. Bradycardia during reversible hypovolaemic shock: associated neural reflex mechanisms and clinical implicationsJ Clin Exp Pharmacol PhysiolYear: 19921973374310.1111/j.1440-1681.1992.tb00411.x
4.. McGee S,Abernethy WB III,Simel DL. The rational clinical examination. Is this patient hypovolemic?JAMAYear: 19992811022102910.1001/jama.281.11.102210086438
5.. Kinsella SM,Tuckey JP. Perioperative bradycardia and asystole: relationship to vasovagal syncope and the Bezold-Jarisch reflexBr J AnaesthYear: 20018685986810.1093/bja/86.6.85911573596
6.. Harms MPM,Lieshout JJ,Jenstrup M,Pott F,Secher NH. Postural effects on cardiac output and mixed venous oxygen saturation in humansExp PhysiolYear: 200388561161610.1113/eph880258012955161
7.. Cooke WH,Ryan KL,Convertino VA. Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humansJ Appl PhysiolYear: 2004961249126110.1152/japplphysiol.01155.200315016789
8.. Secher NH,Lieshout JJ. Normovolaemia defined by central blood volume and venous oxygen saturationClin Exp Pharmacol PhysiolYear: 20053290191010.1111/j.1440-1681.2005.04283.x16405445
9.. Secher NH,Lieshout JJ. Hahn RGHypovolemic shockClinical fluid therapy in the perioperative settingYear: 20112CambridgeCambridge University Press166176
10.. Schadt JC,Ludbrook J. Hemodynamic and neurohumoral responses to acute hypovolemia in conscious mammalsAm J PhysiolYear: 1991260H305H3181671735
11.. Campagna JA,Carter C. Clinical relevance of the Bezold-Jarisch reflexAnesthesiologyYear: 2003981250126010.1097/00000542-200305000-0003012717149
12.. Brassard P, Seifert T, Secher NH. Is cerebral oxygenation negatively affected by infusion of norepinephrine in healthy subjects? Br J Anaesth. 2009;102:800–5.
13.. Singer M,Clarke J,Bennett ED. Continuous hemodynamic monitoring by esophageal DopplerCrit Care MedYear: 19891744745210.1097/00003246-198905000-000142651004
14.. Toska K,Walloe L. Dynamic time course of hemodynamic responses after passive head-up tilt and tilt back to supine positionJ Appl PhysiolYear: 2002921671167611896036
15.. Harms MPM,Wesseling KH,Pott F,Jenstrup M,Goudoever J,Secher NH,Lieshout JJ. Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stressClin SciYear: 19999729130110.1042/CS1999006110464054
16.. Jellema WT,Wesseling KH,Groeneveld AB,Stoutenbeek CP,Thijs LG,Lieshout JJ. Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilutionAnesthesiologyYear: 1999901317132810.1097/00000542-199905000-0001610319780
17.. Bogert LW,Lieshout JJ. Non-invasive pulsatile arterial pressure and stroke volume changes from the human fingerExp PhysiolYear: 20059043744610.1113/expphysiol.2005.03026215802289
18.. Nissen P,Lieshout JJ,Novovic S,Bundgaard-Nielsen M,Secher NH. Techniques of cardiac output measurement during liver transplantation: arterial pulse wave versus thermodilutionLiver TransplYear: 20091528729110.1002/lt.2168919242994
19.. Kurita T,Morita K,Kato S,Kikura M,Horie M,Ikeda K. Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac outputBr J AnaesthYear: 19977977077510.1093/bja/79.6.7709496211
20.. Richard C,Warszawski J,Anguel N,Deye N,Combes A,Barnoud D,Boulain T,Lefort Y,Fartoukh M,Baud F,Boyer A,Brochard L,Teboul JL. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trialJAMAYear: 20032902713272010.1001/jama.290.20.271314645314
21.. Wiener RS,Welch HG. Trends in the use of the pulmonary artery catheter in the United States, 1993–2004JAMAYear: 200729842342910.1001/jama.298.4.42317652296
22.. Shah MR,Hasselblad V,Stevenson LW,Binanay C,O’Connor CM,Sopko G,Califf RM. Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trialsJAMAYear: 20052941664167010.1001/jama.294.13.166416204666
23.. Truijen J,Bundgaard-Nielsen M,Lieshout JJ. A definition of normovolaemia and consequences for cardiovascular control during orthostatic and environmental stressEur J Appl PhysiolYear: 201010914115710.1007/s00421-009-1346-520052592
24.. Hales S. Statical essays: concerning Haemastaticks; or, an account of some hydraulick and hydrostatical experiments made on the blood and blood-vessels of animals. London: Printed for W. Innys and R. Manby; 1733.
25.. Hales S. Foundations of anesthesiology. An account of some hydraulic and hydrostatical experiments made on the blood and blood-vessels of animals. 1710 [classical article]J Clin Monit ComputYear: 200016454710.1023/A:100998063168612578094
26.. Bleichröder F. Intraarterielle TherapieBerliner Klinische WochenschriftYear: 19124915031504
27.. Frank O. Kritik der Elasticchen manometerZ BiolYear: 190344445613
28.. Lambert EH,Wood EH. The use of a resistance wire, strain gauge manometer to measure intraarterial pressureProc Soc Exp Biol MedYear: 19476418619020287374
29.. Peterson LH,Dripps RD,Risman GC. A method for recording the arterial pressure pulse and blood pressure in manAm Heart JYear: 19493777178210.1016/0002-8703(49)90175-118116934
30.. Seldinger SI. Catheter replacement of the needle in percutaneous arteriography; a new techniqueActa RadiolYear: 19533936837610.3109/0001692530913672213057644
31.. Murgo JP, Millar H. A new cardiac catheter for high fidelity differential pressure recordings. In: Proceedings of 25th annual conference on engineering medical biology. Bell Harbour; 1972. p. 303.
32.. Riva-Rocci S. Un nuovo sfigmomanometroGazz Med TorYear: 1896479811017
33.. Riva-Rocci S,Zanchetti A,Mancia G. A new sphygmomanometer. Sphygmomanometric techniqueJ HypertensYear: 19961411212013491
34.. Korotkov NC. On methods of studying blood pressureIzvestiia Voennomedistinskite AkademiiaYear: 190511365
35.. Korotkov NS. Concerning the problem of the methods of blood pressure measurementJ HypertensYear: 200523510.1097/00004872-200501000-0000315643115
36.. Cushing H. On routine determination of arterial tension in operating room and clinicBoston Med Surg JYear: 190314825025610.1056/NEJM190303051481002
37.. Marino PL,Sutin KM. Marino PLArterial blood pressureThe ICU bookYear: 20063PhiladelphiaLippincott Williams & Wilkins151161
38.. Bur A,Hirschl MM,Herkner H,Oschatz E,Kofler J,Woisetschlager C,Laggner AN. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patientsCrit Care MedYear: 20002837137610.1097/00003246-200002000-0001410708169
39.. Bur A,Herkner H,Vlcek M,Woisetschlager C,Derhaschnig U,Delle KG,Laggner AN,Hirschl MM. Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patientsCrit Care MedYear: 20033179379910.1097/01.CCM.0000053650.12025.1A12626986
40.. Wax DB,Lin HM,Leibowitz AB. Invasive and concomitant noninvasive intraoperative blood pressure monitoring: observed differences in measurements and associated therapeutic interventionsAnesthesiologyYear: 201111597397810.1097/ALN.0b013e318233028621952254
41.. Searle NR,Perrault J,Ste-Marie H,Dupont C. Assessment of the arterial tonometer (N-CAT) for the continuous blood pressure measurement in rapid atrial fibrillationCan J AnaesthYear: 19934038839310.1007/BF030096408485800
42.. Steiner LA,Johnston AJ,Salvador R,Czosnyka M,Menon DK. Validation of a tonometric noninvasive arterial blood pressure monitor in the intensive care settingAnaesthesiaYear: 20035844845410.1046/j.1365-2044.2003.03122.x12694001
43.. Szmuk P,Pivalizza E,Warters RD,Ezri T,Gebhard R. An evaluation of the T-Line Tensymeter continuous noninvasive blood pressure device during induced hypotensionAnaesthesiaYear: 20086330731210.1111/j.1365-2044.2007.05369.x18289239
44.. Janelle GM,Gravenstein N. An accuracy evaluation of the T-Line Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patientsAnesth AnalgYear: 200610248449010.1213/01.ane.0000194873.52453.bd16428547
45.. Williams B,Lacy PS,Thom SM,Cruickshank K,Stanton A,Collier D,Hughes AD,Thurston H,O’Rourke M. Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the Conduit Artery Function Evaluation (CAFE) studyCirculationYear: 20061131213122510.1161/CIRCULATIONAHA.105.60696216476843
46.. Roman MJ,Devereux RB,Kizer JR,Lee ET,Galloway JM,Ali T,Umans JG,Howard BV. Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: the Strong Heart StudyHypertensionYear: 20075019720310.1161/HYPERTENSIONAHA.107.08907817485598
47.. Wesseling KH. A century of noninvasive arterial pressure measurement: from Marey to Penaz and FinapresHomeostasisYear: 19953623
48.. Peñáz J. Photoelectric measurement of blood pressure, volume and flow in the finger. 1973; Dresden 1973. p. 104.
49.. Wesseling KH,Wit B,Hoeven GMA,Goudoever J,Settels JJ. Physiocal, calibrating finger vascular physiology for FinapresHomeostasisYear: 1995366782
50.. Ilies C,Bauer M,Berg P,Rosenberg J,Hedderich J,Bein B,Hinz J,Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurementBr J AnaesthYear: 201210820221010.1093/bja/aer39422171358
51.. Gizdulich P,Prentza A,Wesseling KH. Models of brachial to finger pulse wave distortion and pressure decrementCardiovasc ResYear: 19973369870510.1016/S0008-6363(97)00003-59093542
52.. Westerhof BE,Guelen I,Stok WJ,Wesseling KH,Spaan JA,Westerhof N,Bos WJ,Stergiopulos N. Arterial pressure transfer characteristics: effects of travel timeAm J Physiol Heart Circ PhysiolYear: 2007292H800H80710.1152/ajpheart.00443.200616963619
53.. Westerhof BE,Guelen I,Stok WJ,Lasance HA,Ascoop CA,Wesseling KH,Westerhof N,Bos WJ,Stergiopulos N,Spaan JA. Individualization of transfer function in estimation of central aortic pressure from the peripheral pulse is not required in patients at restJ Appl PhysiolYear: 20081051858186310.1152/japplphysiol.91052.200818845775
54.. Bos WJW,Goudoever J,Montfrans GA,Meiracker AH,Wesseling KH. Reconstruction of brachial artery pressure from noninvasive finger pressure measurementsCirculationYear: 1996941870187510.1161/01.CIR.94.8.18708873662
55.. Gizdulich P,Imholz BPM,Meiracker AH,Parati G,Wesseling KH. Finapres tracking of systolic pressure and baroreflex sensitivity improved by waveform filteringJ HypertensYear: 19961424325010.1097/00004872-199602000-000148728303
56.. Imholz BPM,Wieling W,Montfrans GA,Wesseling KH. Fifteen years experience with finger arterial pressure monitoring: assessment of the technologyCardiovasc ResYear: 19983860561610.1016/S0008-6363(98)00067-49747429
57.. Westerhof BE,Guelen I,Parati G,Groppelli A,Van MG,Wieling W,Wesseling KH,Bos WJW. Variable day/night bias in 24-h non-invasive finger pressure against intrabrachial artery pressure is removed by waveform filtering and level correctionJ HypertensYear: 2002201981198610.1097/00004872-200210000-0001712359976
58.. Bogert LW,Wesseling KH,Schraa O,Lieshout EJ,Mol BA,Van GJ,Westerhof BE,Lieshout JJ. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular diseaseAnaesthesiaYear: 2010651119112510.1111/j.1365-2044.2010.06511.x20860647
59.. Eeftinck Schattenkerk DW,Lieshout JJ,Meiracker AH,Wesseling KR,Blanc S,Wieling W,Montfrans GA,Settels JJ,Wesseling KH,Westerhof BE. Nexfin noninvasive continuous blood pressure validated against Riva-Rocci/KorotkoffAm J HypertensYear: 20092237838310.1038/ajh.2008.36819180062
60.. Guelen I,Westerhof BE,Sar GL,Montfrans GA,Kiemeneij F,Wesseling KH,Bos WJ. Validation of brachial artery pressure reconstruction from finger arterial pressureJ HypertensionYear: 2008261321132710.1097/HJH.0b013e3282fe1d28
61.. Jeleazcov C,Krajinovic L,Munster T,Birkholz T,Fried R,Schuttler J,Fechner J. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesiaBr J AnaesthYear: 201010526427210.1093/bja/aeq14320627878
62.. Ng KG. Review of measurement methods and clinical validation studies of noninvasive blood pressure monitors: accuracy requirements and protocol considerations for devices that require patient-specific calibration by a secondary method or device before useBlood Press MonitYear: 20111629130310.1097/MBP.0b013e32834e3c2222064634
63.. Martina JR,Westerhof BE,Goudoever J,De JN,Lieshout JJ,Lahpor JR,Mol BA. Noninvasive blood pressure measurement by the Nexfin monitor during reduced arterial pulsatility: a feasibility studyASAIO JYear: 20105622122710.1097/MAT.0b013e3181d7022720449896
64.. Martina JR, Westerhof BE, Van Goudoever J, de Beaumont EM, Truijen J, Kim YS, Immink RV, Jobsis DA, Hollmann MW, Lahpor JR, De Mol BA, Van Lieshout JJ. Noninvasive continuous arterial blood pressure monitoring with nexfin. Anesthesiology. 2012;116:1092–103.
65.. American national standard for electronic or automated sphygmomanometersYear: 2002ArlingtonAssociation for the Advancement of Medical Instrumentation
66.. Nowak RM,Sen A,Garcia AJ,Wilkie H,Yang JJ,Nowak MR,Moyer ML. Noninvasive continuous or intermittent blood pressure and heart rate patient monitoring in the EDAm J Emerg MedYear: 20112978278910.1016/j.ajem.2011.05.01421802881
67.. Fick A. Ueber die Messung des Blutquantums in den Herzventrikeln. Verhandlungen der Physikalisch-medicinischen Gesellschaft in Wurzburg. Physikalisch-medicinische Gesellschaft in Wurzburg; 1870. p. XVI–XVII.
68.. Frank O. Die Grundform des arteriellen PulsesZ BiolYear: 189937483526
69.. Hamilton WF. Comparison of the Fick and dye-injection methods of measuring the cardiac output in manAm J Physiol Heart Circulatory PhysiologyYear: 1948153309321
70.. Swan HJ,Ganz W,Forrester J,Marcus H,Diamond G,Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheterN Engl J MedYear: 197028344745110.1056/NEJM1970082728309025434111
71.. Erlanger J,Hooker DR. An experimental study of blood pressure and of pulse-pressure in manYear: 1904MarylandPhysiological laboratory of the Johns Hopkins university
72.. Lieshout JJ,Wesseling KH. Continuous cardiac output by pulse contour analysis?Br J AnaesthYear: 20018646746910.1093/bja/86.4.46711573617
73.. Alhashemi JA,Cecconi M,Hofer CK. Cardiac output monitoring: an integrative perspectiveCrit CareYear: 20111521410.1186/cc999621457508
74.. Della RG,Costa MG,Coccia C,Pompei L,Marco P,Vilardi V,Pietropaoli P. Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantationCan J AnaesthYear: 20035070771110.1007/BF0301871412944446
75.. Manecke GR Jr,Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibrationJ Cardiothorac Vasc AnesthYear: 2007213710.1053/j.jvca.2006.08.00417289472
76.. Mayer J,Boldt J,Schollhorn T,Rohm KD,Mengistu AM,Suttner S. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgeryBr J AnaesthYear: 20079817618210.1093/bja/ael34117218375
77.. Opdam HI,Wan L,Bellomo R. A pilot assessment of the FloTrac(TM) cardiac output monitoring systemIntensive Care MedYear: 20073334434910.1007/s00134-006-0410-417063359
78.. Secher NH,Lieshout JJ,Shock Mathias CJ,Bannister RAutonomic failure. A textbook of clinical disorders of the autonomic nervous systemYear: 2011OxfordOxford University Press
79.. Peyton PJ,Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precisionAnesthesiologyYear: 20101131220123510.1097/ALN.0b013e3181ee313020881596
80.. Kubiceck WG,Karnegis JN,Patterson RP,Witsoe DA,Mattson RH. Development and evaluation of an impedance cardiac output systemAerospace MedYear: 196637120812125339656
81.. Moore R,Sansores R,Guimond V,Abboud R. Evaluation of cardiac output by thoracic electrical impedance during exercise in normal subjectsChestYear: 199210244845510.1378/chest.102.2.4481643931
82.. Keren H,Burkhoff D,Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactanceAm J Physiol Heart Circ PhysiolYear: 2007293H583H58910.1152/ajpheart.00195.200717384132
83.. Lieshout JJ,Toska K,Lieshout EJ,Eriksen M,Walloe L,Wesseling KH. Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasoundEur J Appl PhysiolYear: 20039013113710.1007/s00421-003-0901-812851826
84.. Jansen JRC,Wesseling KH,Settels JJ,Schreuder JJ. Continuous cardiac output monitoring by pulse contour during cardiac surgeryEur Heart JYear: 199011Suppl I26322092987
85.. Stok WJ,Baisch F,Hillebrecht A,Schulz H,Meyer M,Karemaker JM. Noninvasive cardiac output measurement by arterial pulse analysis compared with inert gas rebreathingJ Appl PhysiolYear: 199374268726938396105
86.. Antonutto G,Girardis M,Tuniz D,Prampero PE. Noninvasive assessment of cardiac output from arterial pressure profiles during exerciseEur J Appl Physiol Occup PhysiolYear: 199572182410.1007/BF009641098789565
87.. Wieling W,Lieshout JJ,Harkel ADJ. Dynamics of circulatory adjustments to head-up tilt and tilt-back in healthy and sympathetically denervated subjectsClin SciYear: 1998943473529640339
88.. Stok WJ,Stringer RC,Karemaker JM. Noninvasive cardiac output measurement in orthostasis: pulse contour analysis compared with acetylene rebreathingJ Appl PhysiolYear: 1999872266227310601177
89.. Woltjer HH,Bogaard HJ,Scheffer GJ,Spoel HI,Huybregts MA,Vries PM. Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilutionBr J AnaesthYear: 19967774875210.1093/bja/77.6.7489014628
90.. Meer BJ,Woltjer HH,Sousman AM,Schreuder WO,Bulder ER,Huybregts MA,Vries PM. Impedance cardiography. Importance of the equation and the electrode configurationIntensive Care MedYear: 1996221120112410.1007/BF016992398923081
91.. Noblett SE,Snowden CP,Shenton BK,Horgan AF. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resectionBr J SurgYear: 2006931069107610.1002/bjs.545416888706
92.. Gan TJ,Soppitt A,Maroof M,Moalem H,Robertson KM,Moretti E,Dwane P,Glass PS. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgeryAnesthesiologyYear: 20029782082610.1097/00000542-200210000-0001212357146
93.. Bundgaard-Nielsen M,Ruhnau B,Secher NH,Kehlet H. Flow-related techniques for preoperative goal-directed fluid optimizationBr J AnaesthYear: 200798384410.1093/bja/ael28717065167
94.. Westerhof N,Elzinga G,Sipkema P. An artificial arterial system for pumping heartsJ Appl PhysiolYear: 1971317767815117196
95.. Toorop GP,Westerhof N,Elzinga G. Beat-to-beat estimation of peripheral resistance and arterial compliance during pressure transientsAm J PhysiolYear: 1987252H1275H12833591973
96.. Westerhof N,Lankhaar JW,Westerhof BE. The arterial WindkesselMed Biol Eng ComputYear: 20094713114110.1007/s11517-008-0359-218543011
97.. Langewouters GJ,Wesseling KH,Goedhard WJA. The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new modelJ BiomechYear: 19841742553510.1016/0021-9290(84)90034-46480618
98.. Jansen JRC,Schreuder JJ,Mulier JP,Smith NT,Settels JJ,Wesseling KH. A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patientsBr J AnaesthYear: 20018721222210.1093/bja/87.2.21211493492
99.. Wesseling KH,Jansen JRC,Settels JJ,Schreuder JJ. Computation of aortic flow from pressure in humans using a nonlinear, three-element modelJ Appl PhysiolYear: 199374256625738335593
100.. Jellema WT,Groeneveld AB,Wesseling KH,Thijs LG,Westerhof N,Lieshout JJ. Heterogeneity and prediction of hemodynamic responses to dobutamine in patients with septic shockCrit Care MedYear: 2006342392239810.1097/01.CCM.0000233871.52553.CD16849997
101.. Jansen JRC,Versprille A. Improvement of cardiac output estimation by the thermodilution method during mechanical ventilationIntensive Care MedYear: 198612717910.1007/BF002545153700840
102.. Raaijmakers E,Faes TJ,Scholten RJ,Goovaerts HG,Heethaar RM. A meta-analysis of three decades of validating thoracic impedance cardiographyCrit Care MedYear: 1999271203121310.1097/00003246-199906000-0005310397230
103.. Coats AJ. Doppler ultrasonic measurement of cardiac output: reproducibility and validationEur Heart JYear: 199011Suppl I49612092990
104.. Monnet X,Chemla D,Osman D,Anguel N,Richard C,Pinsky MR,Teboul JL. Measuring aortic diameter improves accuracy of esophageal Doppler in assessing fluid responsivenessCrit Care MedYear: 20073547748210.1097/01.CCM.0000254725.35802.1717204996
105.. Sokolski M,Rydlewska A,Krakowiak B,Biegus J,Zymlinski R,Banasiak W,Jankowska EA,Ponikowski P. Comparison of invasive and non-invasive measurements of haemodynamic parameters in patients with advanced heart failureJ Cardiovasc Med (Hagerstown)Year: 20111277377810.2459/JCM.0b013e32834cfebb21941196
106.. Broch O, Renner J, Gruenewald M, Meybohm P, Schöttler J, Caliebe A, Steinfath M, Malbrain M, Bein B. A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia 2012;67:377–83.
107.. Geldorp IE,Delhaas T,Hermans B,Vernooy K,Broers B,Klimusina J,Regoli F,Faletra FF,Moccetti T,Gerritse B,Cornelussen R,Settels JJ,Crijns HJ,Auricchio A,Prinzen FW. Comparison of a non-invasive arterial pulse contour technique and echo Doppler aorta velocity-time integral on stroke volume changes in optimization of cardiac resynchronization therapyEuropaceYear: 201113879510.1093/europace/euq34820880954
108.. Bartels SA,Stok WJ,Bezemer R,Boksem RJ,Van GJ,Cherpanath TG,Lieshout JJ,Westerhof BE,Karemaker JM,Ince C. Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysisJ Clin Monit ComputYear: 20112531532110.1007/s10877-011-9310-422002638
109.. Van der Spoel AG, Voogel AJ, Folkers A, Boer C, Bouwman RA. Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output. J Clin Anesth. 2012;24:304–9.
110.. Lieshout JJ,Wieling W,Karemaker JM,Secher NH. Syncope, cerebral perfusion, and oxygenationJ Appl PhysiolYear: 20039483384812571122
111.. Nissen P,Brassard P,Jorgensen TB,Secher NH. Phenylephrine but not ephedrine reduces frontal lobe oxygenation following anesthesia-induced hypotensionNeurocrit CareYear: 201012172310.1007/s12028-009-9313-x19957053
112.. Bundgaard-Nielsen M,Holte K,Secher NH,Kehlet H. Monitoring of perioperative fluid administration by individualized goal-directed therapyActa Anaesthesiol ScandYear: 20075133134010.1111/j.1399-6576.2006.01221.x17390421
113.. Nowak RM, Sen A, Garcia AJ, Wilkie H, Yang JJ, Nowak MR, Moyer ML. The inability of emergency physicians to adequately clinically estimate the underlying hemodynamic profiles of acutely ill patients. Am J Emerg Med. 2011.
114.. Maggi R,Viscardi V,Furukawa T,Brignole M. Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiologyEuropaceYear: 2010121616162210.1093/europace/euq33320837572
115.. Moya A,Sutton R,Ammirati F,Blanc JJ,Brignole M,Dahm JB,Deharo JC,Gajek J,Gjesdal K,Krahn A,Massin M,Pepi M,Pezawas T,Ruiz GR,Sarasin F,Ungar A,Dijk JG,Walma EP,Wieling W. Guidelines for the diagnosis and management of syncope (version 2009)Eur Heart JYear: 2009302631267110.1093/eurheartj/ehp29019713422
116.. Sipkens LM,Treskes K,Ariese-Beldman K,Veerman DP,Boer C. Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testingBlood Press MonitYear: 20111624625110.1097/MBP.0b013e32834b443121885960
117.. Fedorowski A,Burri P,Juul-Moller S,Melander O. A dedicated investigation unit improves management of syncopal attacks (Syncope Study of Unselected Population in Malmo–SYSTEMA I)EuropaceYear: 2010121322132810.1093/europace/euq16820507854
118.. Gisolf J,Westerhof BE,Dijk N,Wesseling KH,Wieling W,Karemaker JM. Sublingual nitroglycerin used in routine tilt testing provokes a cardiac output-mediated vasovagal responseJ Am Coll CardiolYear: 20044458859310.1016/j.jacc.2004.04.03815358026
119.. Waal EE,Wappler F,Buhre WF. Cardiac output monitoringCurr Opin AnaesthesiolYear: 200922717710.1097/ACO.0b013e32831f44d019295295
120.. Grocott MP,Mythen MG,Gan TJ. Perioperative fluid management and clinical outcomes in adultsAnesth AnalgYear: 20051001093110610.1213/01.ANE.0000148691.33690.AC15781528
121.. Wesseling KH,Smith NT,Nichols WW,Weber H,Wit B,Beneken JEW. Feldman SA,Leigh JM,Spierdijk JBeat-to-beat cardiac output from the arterial pressure pulse contourMeasurement anaesthesiaYear: 1974LeidenLeiden University Press148164

Figures

[Figure ID: Fig1]
Fig. 1 

The differences in pressure levels and wave shape in the radial (red) and finger (blue) arteries. A physiological model can reconstruct the brachial artery pressure (green) from the finger arterial pressure. The staircase is the result of an automatic calibration. (Color figure online)



[Figure ID: Fig2]
Fig. 2 

The cZ pulse contour method, Modelflow and Nexfin CO-trek. The corrected Z (“cZ”, top) method uses an impedance Z to calculate stroke volume (SV) [121]. The time-integral of the arterial pressure wave above diastolic pressure and between valve opening and closing (as determined by upstroke and incisura) is called the pulsatile systolic area (PSA, hashed area in the Figure) of the pressure. This PSA together with the characteristic impedance Zc, which is estimated from age and depending on mean arterial pressure (MAP) and heart rate (HR, the inverse of the heart period of the pressure wave), gives SV. Cardiac output (CO) is calculated by multiplying SV and HR. The method was developed for tracking of changes in CO and for correct absolute values a calibration of Z was necessary. In the Modelflow method (middle) the 3-element Windkessel was implemented. Zc and Windkessel compliance Cw depend on age, gender, height and weight and are nonlinearly related to pressure as shown in the pressure—area relation [97]. Thus, patient data and arterial pressures are both needed to determine these Windkessel parameters [99]. The time varying Rp is the ratio of MAP and CO and iteratively determined. To calculate CO, Modelflow imposes arterial pressure on the Windkessel model. A flow curve is produced of which the time-integral gives SV. The Nexfin CO-trek method (bottom) divides the PSA by the input impedance of the Windkessel to instantaneously give SV. In contrast to Modelflow, there is no need for constructing a flow curve. Moreover while Modelflow was developed to be used on invasive pressures, Nexfin CO-trek was developed to work with noninvasive BP as measured with Nexfin [58].



Tables
[TableWrap ID: Tab1] Table 1 

Methods for measurement of blood pressure and cardiac output


System Method Company CO BP
Nexfin Finger cuff technology/pulse contour analysis BMEYE + ___ + ___
Finometer Finger cuff technology/pulse contour analysis FMS + ___ + ___
LIFEGARD® ICG Thoracic electrical bioimpedance CAS Medical Systems, Inc. + ___ +
BioZ Monitor Impedance cardiography CardioDynamics International Corporation + ___ +
Cheetah reliant “Bioreactance” Cheetah Medical + ___ +
Cardioscreen/Niccomo Impedance cardiography and impedance plethysmography Medis Medizinische Messtechnik GmbH + ___ +
AESCULON Electrical “velocimetry” Osypka Medical GmbH + ___ +
HIC-4000 Impedance cardiography Microtronics Corp Bio Imp Tech, Inc. + ___
NICaS Regional impedance NImedical + ___
IQ2 3-dimensional impedance Noninvasive Medical Technologies + ___
ICON Electrical “velocimetry” Osypka Medical GmbH + ___
PHYSIO FLOW Thoracic electrical bioimpedance Manatec biomedical + ___
AcQtrac Thoracic impedance Väsamed + ___
esCCO Pulse wave transit time Nihon Kohden + ___
TEBCO Thoracic electrical bioimpedance HEMO SAPIENS INC. + ___
NCCOM 3 Impedance cardiography Bomed Medical Manufacturing Ltd + ___
RheoCardioMonitor Impedance cardiography Rheo-Graphic PTE + ___
HemoSonic™ 100 transesophageal Doppler Arrow Critical Care Products + ___
ECOM Endotracheal bioimpedance ConMed Corporation + ___
CardioQ-ODM™ Oesophageal Doppler Deltex + ___
TECO Transesophageal Doppler Medicina + ___
ODM II Transesophageal Doppler Abbott + ___
HDI/PulseWave™ CR-2000 Pressure waveform analysis Hypertension Diagnostics, Inc + _ _ + _ _
USCOM 1A Transthoracic Doppler Uscom + _ _
NICO Rebreathing Fick Philips Respironics +
Innocor Rebreathing Fick Innovision A/S +
Vigileo/FloTrac Pulse contour analysis Edwards Lifesciences ___ ___
LiDCOplus PulseCO Transpulmonary lithium dilution/pulse contour analysis LiDCO Ltd ___ ___
PiCCO2 Transpulmonary thermodilution/pulse contour analysis PULSION Medical Systems AG ___ ___
MOSTCARE PRAM Pulse contour analysis Vytech ___ ___
Vigilance Pulmonary artery catheter thermodilution Edwards Lifesciences ___
DDG Dye-densitogram analyzer Nihon Kohden
Truccom Pulmonary artery catheter thermodilution Omega Critical Care
COstatus Ultrasound dilution Transonic Systems Inc. +
CNAP Monitor 500 Finger cuff technology CNSystems Medizintechnik AG + ___
SphygmoCor® CPV System Applanation tonometry AtCor Medical + _ _
TL-200 T-LINE Applanation tonometry Tensys Medical, Inc. + _ _

+ noninvasive, – invasive, ___ continuous, _ _ semi-continuous, … intermittent



Article Categories:
  • Article

Keywords: Keywords Blood pressure, Cardiac output, Finapres methodology, Nexfin, CO-trek, Pulse contour analysis.

Previous Document:  Tunable synthesis of metal-graphene complex nanostructures and their catalytic ability for solvent-f...
Next Document:  Prepregnancy body mass index and gestational weight gain with the outcome of pregnancy: a 13-year st...