Document Detail


Non-invasive monitoring of intracranial pressure--fact or fancy?
MedLine Citation:
PMID:  3596068     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Ladd and Wright fontanelle pressure meters were applied to the heads of 18 babies, and simultaneously the intracranial pressure was monitored directly. Increasing the force with which the meters were applied caused a linear increase in registered fontanelle pressure. No universally optimal application force could be determined. To obviate this, application force was increased until the fontanelle pressure was calibrated with directly measured intracranial pressure. Subsequent variations in intracranial pressure were significantly correlated to fontanelle pressure, but not closely enough for clinical reliability. The correlation was similar if the meter was affixed instead directly to the scalp with collodion gel, and the clinical reliability improved. Applanation fontanometers are strongly affected by variations in the method by which they are applied and may not be a reliable reflection of intracranial pressure. If directly affixed to the scalp, however, they may yield clinically useful data.
Authors:
A M Kaiser; A G Whitelaw
Related Documents :
12594138 - Extrapolation to zero-flow pressure in cerebral arteries to estimate intracranial press...
1844198 - Effects of thiopentone and mannitol on cerebral perfusion pressure and e.e.g. in head i...
25251068 - Heterogeneity in arterial remodeling among sublines of spontaneously hypertensive rats.
8800328 - Significance of intracranial pressure waveform analysis after head injury.
18956228 - Relationship between manometric and videofluoroscopic measures of swallow function in h...
14980088 - Accuracy of telemedicine in detecting uncontrolled hypertension and its impact on patie...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Developmental medicine and child neurology     Volume:  29     ISSN:  0012-1622     ISO Abbreviation:  Dev Med Child Neurol     Publication Date:  1987 Jun 
Date Detail:
Created Date:  1987-08-12     Completed Date:  1987-08-12     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0006761     Medline TA:  Dev Med Child Neurol     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  320-6     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Head
Humans
Infant
Infant, Newborn
Intracranial Pressure*
Monitoring, Physiologic / methods*
Pressure
Scalp