Noise Reduction to Decrease Radiation Dose and Improve Conspicuity of Hepatic Lesions at Contrast-Enhanced 80-kV Hepatic CT Using Projection Space Denoising.
MedLine Citation:
PMID:  22268185     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
OBJECTIVE: The purpose of this study was to investigate the combined potential of 80-kV CT and noise reduction using a projection space denoising algorithm to reduce radiation dose reduction or to improve the image quality of hepatic CT. MATERIALS AND METhODS: Twenty patients with 56 liver lesions underwent dual-energy (80 and 140 kV) contrast-enhanced hepatic CT. Low-dose 80-kV-only images (comprising 26-54% of the total radiation dose), low-dose 80-kV projection space denoising images (routine and sharper reconstruction kernel), and full-dose mixed-kilovoltage with projection space denoising images were evaluated by three radiologists for lesion conspicuity, image noise, and sharpness. Lesions were compared with full-dose images using 5-point scales (0 = no change, +2 = markedly better, and -2 = markedly worse). Quantitative conspicuity in the form of lesion-to-liver contrast-to-noise ratio (CNR), image noise, and image sharpness were measured.
RESULTS: For all readers, the mean conspicuity rating of low-dose 80-kV projection space denoising images was better than that for full-dose images (mean conspicuity, 0.36-0.57; p < 0.001), with only 1.2% of lesions less conspicuous on 80-kV projection space denoising images. Eighty-kilovolt projection space denoising images reconstructed with a sharper kernel were subjectively similar to full-dose mixed-kilovoltage images comparing image noise (-0.054 to 0.018; p < 0.001 to p = 0.058) and sharpness (-0.64 to -0.09; p < 0.001 to p = 0.057). For 80-kV projection space denoising images with a sharper kernel, lesion-to-liver CNR was slightly higher than that for full-dose mixed-kilovoltage images (p < 0.001), whereas image sharpness and noise were unchanged (p = 0.74 and p = 0.02).
CONCLUSION: Eighty-kilovolt imaging with noise reduction can simultaneously increase lesion conspicuity and facilitate radiation dose reduction and image quality improvement at contrast-enhanced hepatic CT.
Authors:
Eric C Ehman; Luís S Guimarães; Jeff L Fidler; Naoki Takahashi; Juan Carlos Ramirez-Giraldo; Lifeng Yu; Armando Manduca; James E Huprich; Cynthia H McCollough; David Holmes; W Scott Harmsen; Joel G Fletcher
Related Documents :
8214785 - Evaluation of horizontal and vertical differences in facial profiles by orthodontists a...
10947905 - Peculiarities of imaging one- and two-dimensional structures in an emission electron mi...
17564805 - Temporal and spatial change detecting (1998-2003) and predicting of land use and land c...
8529745 - Patterns of integration and clinical value of voiding cystourethrography in the work-up...
16887375 - Robust mosaicing with correction of motion distortions and tissue deformations for in v...
17270445 - Quality of breast imaging reports falls short of recommended standards.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  AJR. American journal of roentgenology     Volume:  198     ISSN:  1546-3141     ISO Abbreviation:  AJR Am J Roentgenol     Publication Date:  2012 Feb 
Date Detail:
Created Date:  2012-01-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7708173     Medline TA:  AJR Am J Roentgenol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  405-11     Citation Subset:  AIM; IM    
Affiliation:
Mayo Medical School, Rochester, MN.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Designing a safer radiology department.
Next Document:  Peak Skin and Eye Lens Radiation Dose From Brain Perfusion CT Based on Monte Carlo Simulation.