New triple-lumen balloon catheter for percutaneous (pulmonary) valvuloplasty.
MedLine Citation:
PMID:  2947694     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Percutaneous transluminal balloon pulmonary valvuloplasty has been performed since 1982. In publications, the most critical problems mentioned are severe systemic hypotension and bradycardia due to stasis of blood flow. A triple-lumen balloon was developed to allow more rapid inflation and deflation and to preserve the preexistent forward blood flow during maximal inflation. Only a slight systemic hypotension and no bradycardia were seen in the first two patients with pulmonary valve stenosis treated with this type of balloon. Thus, the maximal inflation time is not a critical parameter, whereas with the former types of balloon, maximal inflation times were critical, and, if longer than 5 to 10 sec, severe systemic hypotension was registered. We conclude that the triple-lumen pulmonary valve-dilatation balloon catheter is superior to the single-lumen balloon catheter used up to now.
Authors:
E J van den Berg; M G Niemeyer; T W Plokker; S M Ernst; J de Korte
Related Documents :
2273554 - Short-lasting hemodynamic and clinical benefits from percutaneous balloon valvuloplasty...
9728434 - Evaluation of the risks of using an oversized balloon catheter in the human infrarenal ...
20542804 - Acute left main obstructions following tavi.
8518124 - Superiority of balloon occlusion arteriography to reactive hyperemic arteriography in v...
16908574 - Symptomatic stenosis of the cavernous portion of the internal carotid artery due to an ...
10692274 - New ultrasound approaches to dialysis access monitoring.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Catheterization and cardiovascular diagnosis     Volume:  12     ISSN:  0098-6569     ISO Abbreviation:  Cathet Cardiovasc Diagn     Publication Date:  1986  
Date Detail:
Created Date:  1987-02-05     Completed Date:  1987-02-05     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7508512     Medline TA:  Cathet Cardiovasc Diagn     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  352-6     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Balloon / instrumentation*
Dilatation / instrumentation
Heart Catheterization / instrumentation*
Humans
Methods
Middle Aged
Pulmonary Valve Stenosis / congenital,  surgery

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The brachial artery method to transluminal internal mammary artery angioplasty.
Next Document:  Basement membrane matrix in vitro: focal binding of exogenous fibronectin to the matrix of teratocar...