Document Detail


New echocardiographic and angiographic methods for right atrial volume determination: in vitro validation and in vivo results.
MedLine Citation:
PMID:  2614078     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Until now, right atrial (RA) volume calculation by means of two-dimensional echocardiography (2-DE) has only been attempted in a single plane: the apical four-chamber view. Our study reports a new method for RA volume calculation using two intersecting 2-DE views. For this purpose, silicone rubber casts of 19 human necropsy hearts were obtained and thin-walled natural rubber moulds of the RA casts were prepared. Totally filled with and immersed in water, the moulds could be visualized in the apical four-chamber view and an additional 2-DE plane, the latter corresponding to the subcostal view in vivo. In this view the vertical extension of RA could be estimated. Areas and lengths of RA were determined in the respective planes, and RA volume was calculated by applying the formula, area x length, to two intersecting planes. Finally, volume of the silicone casts was determined angiocardiographically (Angio) using a biplane method (30 degrees RAO, 40 degrees LAO-40 degrees hepatoclavicular). The true RA volume was 106 +/- 23 ml (mean +/- 1 SD) as determined by water displacement. Using Angio an excellent correlation was found: the calculated volume amounted to 106 +/- 23 ml; the difference was 5.5 +/- 4.8 ml (n.s.); Angio vol = 0.93 true vol + 7.77; r = 0.95; SEE = 7.4 ml. Volume determination from the apical four-chamber view of 2-DE using a monoplane disk method resulted in a mean volume of 62 +/- 17 ml. The mean difference to the true RA volume was 44 +/- 16 ml (p less than 0.001). When volume calculations were made using the biplane method, a value of 105 +/- 22 ml resulted. The mean difference to true volumes was 7.4 +/- 4.8 ml: y = 0.84x + 15.88; r = 0.91; SEE = 9.4 ml. In an in vivo study endsystolic RA volumes were calculated in a normal adult population (n = 40) from the same intersecting planes as in vitro. A normal value of 38 +/- 6 ml/m2 was found. In vivo validation using Angio showed a slightly higher normal value of 43 = 7 ml/m2. Thus, 2-DE is highly accurate in determining RA volume. In the in vitro as well as in the in vivo study the results of monoplane calculations are clearly inferior to a method which also takes account of the vertical extension of RA.
Authors:
H Lambertz; F A Flachskampf; R Heiliger; W Krebs; B Behrens; E Schmitz
Related Documents :
7897128 - Preserved right ventricular ejection fraction predicts exercise capacity and survival i...
19555838 - The pathophysiology of heart failure with normal ejection fraction: exercise echocardio...
6587758 - Effects of intravenous verapamil on the haemodynamic response to exercise in patients w...
1008968 - Haemodynamic adaptation at rest and during exercise to long-term antihypertensive treat...
1748858 - Cardiac left ventricular function before and during early thyroxine treatment in severe...
24928318 - Effect of interval training exercise on subchondral bone in a chemically-induced osteoa...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  International journal of cardiac imaging     Volume:  5     ISSN:  0167-9899     ISO Abbreviation:  Int J Card Imaging     Publication Date:  1989  
Date Detail:
Created Date:  1990-02-26     Completed Date:  1990-02-26     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8600426     Medline TA:  Int J Card Imaging     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  39-51     Citation Subset:  IM    
Affiliation:
Department of Internal Medicine I, Pathology and Statistics and Documentation, Rheinisch-Westfälische Technische Hochschule, Aachen, FRG.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Cardiac Volume*
Cineangiography*
Echocardiography*
Heart / anatomy & histology*,  radiography
Heart Atria
Humans
Middle Aged
Models, Anatomic

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Intraoperative sonographic measurements of the internal mammary artery as a coronary bypass conduit.
Next Document:  Digital flashing tomosynthesis (DFTS)--a technique for three-dimensional coronary angiography.