Document Detail

New approach to the diagnosis of patent ductus arteriosus during catheterization.
MedLine Citation:
PMID:  10348138     Owner:  NLM     Status:  MEDLINE    
The diagnosis of patent ductus arteriosus (PDA) usually requires catheterization, as does percutaneous treatment of the disorder. To obtain pressure gradients, a catheter can be passed in either direction through the PDA, from the pulmonary artery to the aorta or via the more common route of aorta to pulmonary artery. Several types of catheters have been used, but to date there have been no reports showing the use of a left internal mammary artery (LIMA) angiographic catheter for this purpose. We report successful passage of this catheter from the aorta across a PDA to the pulmonary artery in 15 adult patients who were observed to have no complications.
C Erdöl; H F Töre
Related Documents :
21095378 - Rapid two-stage starnes procedure for a symptomatic neonate with ebstein anomaly.
9988808 - A randomized double-blind study comparing the fetal effects of sulindac to terbutaline ...
20539418 - Patents.
15725148 - Successful treatment of mucormycosis in the pulmonary artery after cardiac surgery.
19430268 - Case report of a patient who underwent thrombolysis of a "silent" thrombus in the middl...
19330248 - Effects of cardiopulmonary bypass on propofol pharmacokinetics and bispectral index dur...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions     Volume:  46     ISSN:  1522-1946     ISO Abbreviation:  Catheter Cardiovasc Interv     Publication Date:  1999 Mar 
Date Detail:
Created Date:  1999-07-06     Completed Date:  1999-07-06     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  100884139     Medline TA:  Catheter Cardiovasc Interv     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  350-1     Citation Subset:  IM    
Department of Cardiology, Medical Faculty of Karadeniz Technical University, Trabzon, Turkey.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Ductus Arteriosus, Patent / diagnosis*
Heart Catheterization / instrumentation,  methods*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Unexpanded, irretrievable stent in the proximal right coronary artery: successful management with st...
Next Document:  Combined use of Orgaran and Reopro during coronary angioplasty in patients unable to receive heparin...