Document Detail


Neonatal effects of patient-controlled analgesia using fentanyl in labor.
MedLine Citation:
PMID:  15321226     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
Patient-controlled analgesia (PCA) has been used at our institution for the past 5 years, as an alternative labor analgesic when epidural analgesia is contraindicated. This retrospective study evaluates the effects of maternal PCA fentanyl on infants of greater than 32 weeks gestational age. The neonatal charts (n=32) were reviewed for birth weight, gestational age, 1 min and 5 min Apgar scores, use of naloxone and umbilical venous gases. Infants requiring naloxone were defined as narcotized. Results from narcotized and non-narcotized neonates were compared with the Wilcoxon two-sample test. Fourteen infants had a 1 min Apgar score <or= 6. At 5 min the Apgar scores were all >or= 7, except in the three infants who had received naloxone. Gestational age, birth weight, method of delivery, PCA duration, time from last dose to delivery, total fentanyl used and rate of fentanyl infusion were not predictive of low 1 min Apgar scores. Three infants with a 1 min Apgar of 4 required naloxone. The total fentanyl received by mothers of infants who required naloxone was significantly higher than the group of mothers whose infants did not require naloxone (770 +/- 233 microg vs 298 +/- 287 microg, P = 0.027) Use of PCA fentanyl in this high-risk obstetric population was associated with a 44% incidence of moderately depressed neonates with an Apgar score <or= 6 at 1 min. Prospective controlled trials are needed to determine optimum PCA parameters in labor.
Authors:
P K Morley-Forster; J Weberpals
Related Documents :
6126986 - Use of beta-receptor agonists in obstetrics.
11235436 - Regulation of uterine contraction: mechanisms in preterm labor.
24644706 - Prognosis-based guidelines for treatment limitation decisions in newborn infants.
1988886 - Low incidence of positive amnionic fluid cultures in preterm labor at 27-32 weeks in th...
17022336 - The use of infant seating devices in child care centers.
22468126 - Ankyloglossia and breastfeeding.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  International journal of obstetric anesthesia     Volume:  7     ISSN:  0959-289X     ISO Abbreviation:  Int J Obstet Anesth     Publication Date:  1998 Apr 
Date Detail:
Created Date:  2004-08-23     Completed Date:  2005-02-24     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9200430     Medline TA:  Int J Obstet Anesth     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  103-7     Citation Subset:  -    
Affiliation:
Department of Anaesthesia, St Joseph's Health Centre, P.O. Box 5777, London, Ontario, Canada N6A 41-6.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Analgesia produced by epidural diamorphine is better following caesarean section under spinal anaest...
Next Document:  Maternal temperature during labour using low-dose (ambulatory) epidural analgesia with bupivacaine a...