Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.
MedLine Citation:
PMID:  23297759     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE: To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. METHODS: An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree(-1) were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. RESULTS: At a 3-mm pupil we only found statistically significant differences in VA between the two simulated surgeries at low-contrast for moderate- and high-myopic astigmatism (p < 0.05). Statistically significant differences were found in CS at 3-mm pupil between both procedures at the highest spatial frequency for moderate-myopic astigmatism and at all frequencies for high-myopic astigmatism (p < 0.05). At a 5-mm pupil we found statistically significant differences in VA and CS between both simulated surgeries at all contrasts and frequencies evaluated for both groups (p < 0.05). In all cases VA and CS were better with the TICL than with the bioptics technique. MTFs for the bioptics technique were worse than those computed for the TICL. The TICL showed less spread out of the PSF than the bioptics procedure. CONCLUSIONS: Simulated TICL and bioptics procedures provided good optical and visual quality, although TICL implantation provided slightly better outcomes than the bioptics procedure, especially when the pupil diameter was increased.
Authors:
Cari Pérez-Vives; Alberto Domínguez-Vicent; David Madrid-Costa; Teresa Ferrer-Blasco; Robert Montés-Micó
Related Documents :
18077939 - Depth of penetration of an 850nm wavelength low level laser in human skin.
9290139 - Hippocratic thermography.
25257919 - An ununsual case of impossible communication between an icd and programmer.
7687149 - 85sr contaminant as a reliable tracer of 89sr for monitoring urinary radioactivity in p...
21846559 - Regenerative endodontic treatment (revascularization) of immature necrotic molars medic...
11921789 - Retrieval of the ultraviolet aerosol optical depth during a spring campaign in the bava...
19853169 - A removable partial denture using an esthetically designed round-rest distal clasp on m...
9683699 - Digital imaging: a valuable technique for the postoperative assessment of cochlear impl...
10894429 - Interfacial adaptation of a class ii polyacid-modified resin composite/resin composite ...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-9
Journal Detail:
Title:  Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)     Volume:  -     ISSN:  1475-1313     ISO Abbreviation:  Ophthalmic Physiol Opt     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-9     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8208839     Medline TA:  Ophthalmic Physiol Opt     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
Affiliation:
GIO, Optics Department, Faculty of Physics, Universidad de Valencia, Valencia, Spain.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Evaluation of the association between long-lasting insecticidal nets mass distribution campaigns and...
Next Document:  Dietary intervention for oral allergy syndrome as a treatment in orofacial granulomatosis: a new app...