Document Detail


Multipathway sequences for MR thermometry.
MedLine Citation:
PMID:  21394774     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
MR-based thermometry is a valuable adjunct to thermal ablation therapies as it helps to determine when lethal doses are reached at the target and whether surrounding tissues are safe from damage. When the targeted lesion is mobile, MR data can further be used for motion-tracking purposes. The present work introduces pulse sequence modifications that enable significant improvements in terms of both temperature-to-noise-ratio properties and target-tracking abilities. Instead of sampling a single magnetization pathway as in typical MR thermometry sequences, the pulse-sequence design introduced here involves sampling at least one additional pathway. Image reconstruction changes associated with the proposed sampling scheme are also described. The method was implemented on two commonly used MR thermometry sequences: the gradient-echo and the interleaved echo-planar imaging sequences. Data from the extra pathway enabled temperature-to-noise-ratio improvements by up to 35%, without increasing scan time. Potentially of greater significance is that the sampled pathways featured very different contrast for blood vessels, facilitating their detection and use as internal landmarks for tracking purposes. Through improved temperature-to-noise-ratio and lesion-tracking abilities, the proposed pulse-sequence design may facilitate the use of MR-monitored thermal ablations as an effective treatment option even in mobile organs such as the liver and kidneys. Magn Reson Med, 2011. © 2011 Wiley-Liss, Inc.
Authors:
Bruno Madore; Lawrence P Panych; Chang-Sheng Mei; Jing Yuan; Renxin Chu
Related Documents :
8544004 - Nuclear arthrography: combined scintigraphic and radiographic procedure for diagnosis o...
17674064 - Radiologic findings in tsunami trauma: experience with 225 patients injured in the 2004...
9208294 - Radiographic and computed tomographic evaluation of lisfranc dislocation: a cadaver study.
16554584 - Detection of strictures on upper gastrointestinal tract radiographic examinations after...
7729074 - Gliomatosis cerebri: report of an atypical case.
21981784 - Optimising μct imaging of the middle and inner cat ear.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-3-9
Journal Detail:
Title:  Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine     Volume:  -     ISSN:  1522-2594     ISO Abbreviation:  -     Publication Date:  2011 Mar 
Date Detail:
Created Date:  2011-3-11     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8505245     Medline TA:  Magn Reson Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2011 Wiley-Liss, Inc.
Affiliation:
Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA. bruno@bwh.harvard.edu.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Analytic expressions for the ultimate intrinsic signal-to-noise ratio and ultimate intrinsic specifi...
Next Document:  Measurement of glycine in the human brain in vivo by (1) H-MRS at 3 T: application in brain tumors.