Abstract/OtherAbstract:
|
Multimodality vascular flow phantoms provide a way of testing the geometric accuracy of clinical scanners and optimizing acquisition protocols with easy reproducibility of experimental conditions. This article presents a stereolithography method combined with a lost-material casting technique that eliminates metal residues of cerrolow (a low temperature melting point metallic alloy) left within irregular vessel lumens after casting. These residues potentially cause image artifacts especially in magnetic resonance angiography or flow disturbance. Geometrical accuracies of constructed lumens with isomalt, the proposed material, ranged from 3.3% to 5.7% for vessel diameters of 1.8-7.9 mm, which are comparable to those of lumens constructed with cerrolow that had better accuracies varying from 1.1% to 4.1% (p<0.02). Examples of geometries mimicking diseased arteries such as an aorta with stenosed renal arteries and an iliac artery with multiple stenoses are presented. This sugar-based isomalt material, combined with phantom designs having fiducial markers visible in digital subtraction angiography, computed tomography angiography, magnetic resonance angiography, and ultrasound [Med. Phys. 31, 1424-1433 (2004)], makes easier the fabrication of complex realistic and accurate replicas of pathological vessels with lumen irregularities. |
| | |
Authors:
|
Louise Allard; Gilles Soulez; Boris Chayer; Fran??ois Treyve; Zhao Qin; Guy Cloutier |
Related Documents
:
|
17715119 - Incidental findings on renal mr angiography. 11108759 - Perimesencephalic hemorrhage and ct angiography: a decision analysis. 19774439 - Comparison between 64-row ct angiography and digital subtraction angiography in the stu... 10715029 - Mr angiography of the intracranial venous system. 12148439 - Portal vein aneurysm; ct, mr and mr angiography appearances. 10541389 - Breath-hold 3d gadolinium-enhanced subtraction mra in the detection of transplant renal... 21394779 - Simultaneous dual-nuclei imaging for motion corrected detection and quantification of (... 17804879 - Spatio-temporal analysis of molecular delivery through the blood-brain barrier using fo... 12679629 - Characterization of focal liver lesions with superparamagnetic iron oxide-enhanced mr i... |
Publication Detail:
|
Type: Journal Article; Research Support, Non-U.S. Gov't |
Journal Detail:
|
Title: Medical physics Volume: 36 ISSN: 0094-2405 ISO Abbreviation: - Publication Date: 2009 Aug |
Date Detail:
|
Created Date: 2009-09-14 Completed Date: 2009-09-30 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0425746 Medline TA: Med Phys Country: United States |
Other Details:
|
Languages: eng Pagination: 3758-63 Citation Subset: IM |
Affiliation:
|
Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montr??al, Qu??bec H2L 2W5, Canada. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Aorta Blood Vessels* Diagnostic Imaging / instrumentation* Humans Iliac Artery Phantoms, Imaging* |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.
Next Document: An alternative VMAT with prior knowledge about the type of leaf motion utilizing projection method f...