Multilaboratory particle image velocimetry analysis of the FDA benchmark nozzle model to support validation of computational fluid dynamics simulations.
MedLine Citation:
PMID:  21428676     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
This study is part of a FDA-sponsored project to evaluate the use and limitations of computational fluid dynamics (CFD) in assessing blood flow parameters related to medical device safety. In an interlaboratory study, fluid velocities and pressures were measured in a nozzle model to provide experimental validation for a companion round-robin CFD study. The simple benchmark nozzle model, which mimicked the flow fields in several medical devices, consisted of a gradual flow constriction, a narrow throat region, and a sudden expansion region where a fluid jet exited the center of the nozzle with recirculation zones near the model walls. Measurements of mean velocity and turbulent flow quantities were made in the benchmark device at three independent laboratories using particle image velocimetry (PIV). Flow measurements were performed over a range of nozzle throat Reynolds numbers (Re(throat)) from 500 to 6500, covering the laminar, transitional, and turbulent flow regimes. A standard operating procedure was developed for performing experiments under controlled temperature and flow conditions and for minimizing systematic errors during PIV image acquisition and processing. For laminar (Re(throat)=500) and turbulent flow conditions (Re(throat)≥3500), the velocities measured by the three laboratories were similar with an interlaboratory uncertainty of ∼10% at most of the locations. However, for the transitional flow case (Re(throat)=2000), the uncertainty in the size and the velocity of the jet at the nozzle exit increased to ∼60% and was very sensitive to the flow conditions. An error analysis showed that by minimizing the variability in the experimental parameters such as flow rate and fluid viscosity to less than 5% and by matching the inlet turbulence level between the laboratories, the uncertainties in the velocities of the transitional flow case could be reduced to ∼15%. The experimental procedure and flow results from this interlaboratory study (available at http://fdacfd.nci.nih.gov) will be useful in validating CFD simulations of the benchmark nozzle model and in performing PIV studies on other medical device models.
Authors:
Prasanna Hariharan; Matthew Giarra; Varun Reddy; Steven W Day; Keefe B Manning; Steven Deutsch; Sandy F C Stewart; Matthew R Myers; Michael R Berman; Greg W Burgreen; Eric G Paterson; Richard A Malinauskas
Related Documents :
22358236 - Is the measurement of inferior thyroid artery blood flow velocity by color-flow doppler...
15460336 - Rapid and simple mutation screening of g(m1) gangliosidosis in shiba dogs by direct amp...
3784456 - Factors influencing in vitro sieving of blood in cerebrovascular accidents. clinical si...
18256216 - Dried-blood sampling for epstein-barr virus immunoglobulin g (igg) and iga serology in ...
4034366 - Skin ava and capillary dilatation and constriction induced by local skin heating.
597666 - The influence of vasoactive substances on blood flow and contractile responses of cat g...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of biomechanical engineering     Volume:  133     ISSN:  1528-8951     ISO Abbreviation:  J Biomech Eng     Publication Date:  2011 Apr 
Date Detail:
Created Date:  2011-03-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7909584     Medline TA:  J Biomech Eng     Country:  United States    
Other Details:
Languages:  eng     Pagination:  041002     Citation Subset:  IM    
Affiliation:
Food and Drug Administration, Silver Spring, MD 20993.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The specific growth rates of tissues: a review and a re-evaluation.
Next Document:  In Vitro Validation of Finite-Element Model of AAA Hemodynamics Incorporating Realistic Outlet Bound...