Document Detail


Multidose vial contamination in anesthesia.
MedLine Citation:
PMID:  2275319     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The intent of this research was to address the following question: Will an alteration in the drug aspiration technique cause a significant difference in the incidence of multidose vial contamination? The control group consisted of multidose vials collected at the end of each day from staff anesthetists. The use of these vials reflected the practice technique of a single needle and syringe for each vial. The vial, as well as needle and syringe, were used on all cases managed for the day. The experimental group consisted of multidose vials collected at the end of each day from the four investigators. The vials and syringes were utilized in the same manner as the control group with the exception that a new needle was used each time a vial was reentered. Upon completion of the collection period, guaiac testing, using Hemoccult slides and developer, was performed on a 0.1 cc sample from each vial. A multidose vial was considered positive for blood contamination if traces of blue appeared on the Hemoccult slide in a 15-minute period. A chi-square statistic was applied to the cumulative data. The control group consisted of 492 multidose vials. Of the 492 multidose vials tested, 11 were guaiac positive, 2.24%. The experimental group consisted of 369 multidose vials. Of the 369 multidose vials, one tested guaiac positive, 0.27%. A chi-square test on the cumulative data demonstrated a significant (p less than .05) difference between the two groups. The research demonstrated that occult blood may be contained within the used multidose vials suggesting that contaminated drug may then be injected into another patient.(ABSTRACT TRUNCATED AT 250 WORDS)
Authors:
M E Arrington; K C Gabbert; P W Mazgaj; M T Wolf
Related Documents :
2912409 - Improved safety of glucagon testing for pheochromocytoma by prior alpha-receptor blocka...
12666019 - Sensitivity, specificity, and predictive values of reagent test strip estimations of bl...
18770289 - A reverse transcriptase assay for the diagnosis of lymphoproliferative disease (lpd) of...
7955939 - Effect of acute dose of caffeine on cardiovascular autonomic responses in healthy subje...
19073389 - Preoperative haemostasis testing does not predict requirement of blood products in card...
15217609 - Raman analysis of prion protein in blood cell membranes from naturally affected scrapie...
3944889 - Is intracavernous injection of papaverine a reliable screening test for vascular impote...
22072819 - Development and clinical evaluation of a rapid serodiagnostic test for toxoplasmosis of...
3463719 - Laboratory studies of visible-light cured fissure sealants: setting times and depth of ...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  AANA journal     Volume:  58     ISSN:  0094-6354     ISO Abbreviation:  AANA J     Publication Date:  1990 Dec 
Date Detail:
Created Date:  1991-02-28     Completed Date:  1991-02-28     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0431420     Medline TA:  AANA J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  462-6     Citation Subset:  N    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Drug Packaging*
Equipment Contamination*
Humans
Injections / methods*
Nurse Anesthetists
Nursing Care / methods,  standards*
Nursing Evaluation Research
Occult Blood
Suction / methods*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Role of protons and bicarbonate in adaptative gastric cytoprotection
Next Document:  AANA Journal course: new technologies in anesthesia: update for nurse anesthetists--high frequency v...