Document Detail


Multidetector-row helical CT: analysis of time management and workflow.
MedLine Citation:
PMID:  11870487     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (+/- 2.06 min); (b) 4:36 min (+/- 2.43 min); (c) 4:11 min (+/- 2.55 min); (d) 0:43 min (+/- 0.15 min); (e) 6:59 min (+/- 2.39 min); (f) 09:51 min (+/- 3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, respectively. Reconstruction time was highest for HRCT (9:22 min) and CTA (9:03 min). Data storage/printing was most time-consuming for HRCT (13:02 min), followed by combined neck-chest-abdomen examinations (12:19 min). Comparing the two time periods, during which a software update was performed, a mean time reduction of 4:31 min per patient (15%, p<0.001) was achieved. Whereas CT data acquisition time is no longer a problem with MDCT, patient management, data reconstruction, and data storage are the most time-consuming parts. Well-trained technicians, state-of-the-art workstations, and fast networking are the most important factors to improve workflow.
Authors:
Justus E Roos; Lotus M Desbiolles; Jürgen K Willmann; Dominik Weishaupt; Borut Marincek; Paul R Hilfiker
Related Documents :
22130787 - Application of ex vivo micro-computed tomography for assessment of in vivo fluorescence...
10619247 - Spatially varying longitudinal aliasing and resolution in spiral computed tomography.
21984417 - A method for the automatic quantification of the completeness of pulmonary fissures: ev...
9646807 - Dual-helical ct for detecting aortic atheromas as a source of stroke: comparison with t...
22274977 - A case of primary diffuse leptomeningeal gliomatosis predominantly involving the cervic...
16996757 - Transient acute obstructive hydrocephalus of unknown origin in a 13-month-old infant.
Publication Detail:
Type:  Evaluation Studies; Journal Article     Date:  2001-10-16
Journal Detail:
Title:  European radiology     Volume:  12     ISSN:  0938-7994     ISO Abbreviation:  Eur Radiol     Publication Date:  2002 Mar 
Date Detail:
Created Date:  2002-02-28     Completed Date:  2002-04-12     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9114774     Medline TA:  Eur Radiol     Country:  Germany    
Other Details:
Languages:  eng     Pagination:  680-5     Citation Subset:  IM    
Affiliation:
Institute of Diagnostic Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Efficiency, Organizational*
Humans
Radiology Department, Hospital / organization & administration*
Time Management*
Tomography, X-Ray Computed* / instrumentation,  methods

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Guidelines and algorithms: strategies for standardization of referral criteria in diagnostic radiolo...
Next Document:  Comparison in myelography between iodixanol 270 and 320 mgI/ml and iotrolan 300 mgI/ml: a multicentr...