"Motion-resistant" pulse oximetry: a comparison of new and old models.
MedLine Citation:
PMID:  12351278     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Several pulse oximeter manufacturers have recently developed instruments that are claimed to be resistant to the effects of patient motion. We performed a laboratory volunteer experiment to compare the performances of several of these instruments, as well as some older models, during combinations of motion and hypoxemia. Twenty oximeters were studied. A motorized table produced different hand motions, and each motion was studied during both room air breathing and hypoxemia. Pulse oximeters on the nonmoving hand were used to provide control measurements for comparison. The Masimo SET((R)) pulse oximeter exhibited the best overall performance, with a performance index (percentage of time in which the SpO(2) reading is within 7% of control value) of 94%. The Agilent Viridia 24C was next, with an 84% index, followed by the Agilent CMS (80%), the Datex-Ohmeda 3740 (80%), and the Nellcor N-395 (69%). For comparison with older oximeter technology, the Criticare 5040 had an index of 28%. Recent technology changes have significantly improved pulse oximeter performance during motion artifact, with the Masimo oximeter leading the way. IMPLICATIONS. New improvements in pulse oximeter technology have resulted in significantly better accuracy and reliability during patient motion. The Masimo pulse oximeter demonstrated the best performance of the 20 instruments tested.
Authors:
Steven J Barker
Related Documents :
25102388 - Seeing liquids from visual motion.
6238128 - Auditory perception of breaking and bouncing events: a case study in ecological acoustics.
24663918 - Elimination of light leakage over the entire viewing cone in a homogeneously-aligned li...
1432068 - Force response of rat soleus muscle to variable-frequency train stimulation.
1843768 - Electroretinographic changes in aged pigeons.
7934858 - Sensory rhodopsin-controlled release of the switch factor fumarate in halobacterium sal...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Evaluation Studies; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Anesthesia and analgesia     Volume:  95     ISSN:  0003-2999     ISO Abbreviation:  Anesth. Analg.     Publication Date:  2002 Oct 
Date Detail:
Created Date:  2002-09-27     Completed Date:  2002-10-28     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  1310650     Medline TA:  Anesth Analg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  967-72, table of contents     Citation Subset:  AIM; IM    
Affiliation:
Department of Anesthesiology, University of Arizona, Tucson, Arizona 85724, USA. sjbarker@u.arizona.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Anoxia / blood
Fingers / physiology
Humans
Models, Biological
Motion
Oximetry / instrumentation*
Oxygen / blood
ROC Curve
Regional Blood Flow / physiology
Chemical
Reg. No./Substance:
7782-44-7/Oxygen

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The influence of active warming on signal quality of pulse oximetry in prehospital trauma care.
Next Document:  The effect of chronic oral desipramine on capsaicin-induced allodynia and hyperalgesia: a double-bli...