Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases.
MedLine Citation:
PMID:  18422796     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A new digital computer mock circulatory system has been developed in order to replicate the physiologic and pathophysiologic characteristics of the human cardiovascular system. The computer performs the acquisition of pressure, flow, and temperature in an open loop system. A computer program has been developed in Labview programming environment to evaluate all these physical parameters. The acquisition system was composed of pressure, flow, and temperature sensors and also signal conditioning modules. In this study, some results of flow, cardiac frequencies, pressures, and temperature were evaluated according to physiologic ventricular states. The results were compared with literature data. In further works, performance investigations will be conducted on a ventricular assist device and endoprosthesis. Also, this device should allow for evaluation of several kinds of vascular diseases.
Authors:
Daniel Legendre; Jeison Fonseca; Aron Andrade; José Francisco Biscegli; Ricardo Manrique; Domingos Guerrino; Akash Kuzhiparambil Prakasan; Jaime Pinto Ortiz; Julio Cesar Lucchi
Related Documents :
8463806 - Cable-testing device fails to indicate that hypertension is artifactual.
6716186 - Blood pressure self-monitoring in the workplace.
11231706 - Are aneroid sphygmomanometers accurate in hospital and clinic settings?
8126536 - Prevention of air introduction in catheter-manometer systems for accurate neonatal bloo...
19388776 - A theoretical study of mechanical stability of arteries.
8493596 - Correlation between intravascular pressure and risk of hemorrhage due to arteriovenous ...
Publication Detail:
Type:  Journal Article     Date:  2008-04-16
Journal Detail:
Title:  Artificial organs     Volume:  32     ISSN:  1525-1594     ISO Abbreviation:  Artif Organs     Publication Date:  2008 Jun 
Date Detail:
Created Date:  2008-06-04     Completed Date:  2008-07-08     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  United States    
Other Details:
Languages:  eng     Pagination:  461-7     Citation Subset:  IM    
Affiliation:
Institute Dante Pazzanese of Cardiology, Escola Politécnica, University of São Paulo, Brazil. daniel.legendre@poli.usp.br
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Circulation / physiology
Blood Pressure / physiology
Blood Vessel Prosthesis
Cardiovascular System / physiopathology
Compliance
Computer Simulation*
Flowmeters
Heart Rate / physiology
Heart-Assist Devices
Hemodynamics / physiology
Humans
Models, Cardiovascular*
Pulsatile Flow
Rheology
Signal Processing, Computer-Assisted / instrumentation*
Software*
Temperature
Vascular Diseases / physiopathology
Vascular Resistance / physiology
Viscosity

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Antithrombogenic properties of a monopivot magnetic suspension centrifugal pump for circulatory assi...
Next Document:  Uremic pruritus, cytokines, and polymethylmethacrylate artificial kidney.