Document Detail


Minimum protection factors for respiratory protective devices for firefighters.
MedLine Citation:
PMID:  842565     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Carbon monoxide and oxygen concentrations were measured in seventy-two structural fires using a personal air sampler carried by working firefighters. In a total sampling time of 1329 minutes the carbon monoxide concentration exceeded 500 ppm approximately 29 percent of the time. The maximum carbon monoxide concentration was 27,000 ppm and in 10 percent of the fires, the maximum concentration exceeded 5500 ppm. Only six runs indicated oxygen concentrations less than 18 percent. On the basis of these exposure data, a minimum protection factor of 100 is proposed for breathing apparatus for structural firefighting.
Authors:
W A Burgess; R Sidor; J J Lynch; P Buchanan; E Clougherty
Related Documents :
25474065 - Implementation of quality systems by mexican exporters of processed meat.
23060675 - A comparison of differential reinforcement and noncontingent reinforcement to treat foo...
15214445 - Assessing the effectiveness of ozonation followed by gac filtration in removing bromate...
16586085 - Orientation response of haematophagous bugs to co2: the effect of the temporal structur...
24300825 - The malabsorption of commonly occurring mono and disaccharides.
24896965 - Effects of reinforcer type on rats' sensitivity to variation in reinforcer amount and r...
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  American Industrial Hygiene Association journal     Volume:  38     ISSN:  0002-8894     ISO Abbreviation:  Am Ind Hyg Assoc J     Publication Date:  1977 Jan 
Date Detail:
Created Date:  1977-04-15     Completed Date:  1977-04-15     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0371160     Medline TA:  Am Ind Hyg Assoc J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  18-23     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Air / analysis
Carbon Monoxide / analysis
Fires*
Oxygen / analysis
Protective Devices*
Respiratory Protective Devices*
Smoke
Time Factors
Chemical
Reg. No./Substance:
0/Smoke; 630-08-0/Carbon Monoxide; 7782-44-7/Oxygen