Miniature Fabry-Perot pressure sensor created by using UV-molding process with an optical fiber based mold.
MedLine Citation:
PMID:  22714519     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
We present a miniature Fabry-Perot pressure sensor fabricated at the tip of an optical fiber with a pre-written Bragg grating by using UV-molding polymer process. The mold is constructed by integrating an optical fiber of 80 μm diameter with a zirconia ferrule. The optical fiber based mold makes it possible to use optical aligning method to monitor the coupled intensity between the mold-side and replica-side fibers, rendering a maskless alignment process with a submicrometer accuracy. A polymer-metal composite thin diaphragm is employed as the pressure transducer. The overall sensor size is around 200 μm in diameter. Experimental study shows that the sensor exhibits a good linearity over a pressure range of 1.9-7.9 psi, with a sensitivity of 0.0106 μm/psi. The fiber Bragg grating is exploited for simultaneous temperature measurements or compensation for temperature effects in pressure readings. The sensor is expected to benefit many fronts that require miniature and inexpensive sensors for reliable pressure measurement, especially biomedical applications.
Authors:
H Bae; M Yu
Related Documents :
16005099 - Walking for exercise--does three times per week influence risk factors in type 2 diabetes?
16857549 - Lipid infusion accelerates removal of bupivacaine and recovery from bupivacaine toxicit...
1721979 - Effects of carvedilol on serum lipids in patients with essential hypertension.
22502549 - High-pressure effect on the dynamics of solvated peptides.
3291559 - Are effects of antihypertensive treatment on lipoproteins merely "side-effects"? a comp...
18071779 - High sensitivity c-reactive protein and endothelial function in chilean patients with h...
18603749 - Treatment of ethanol-induced acute pulmonary hypertension and right ventricular dysfunc...
12529869 - Non-linear models for the relation between cardiovascular risk factors and intake of wi...
11465229 - Hemodynamic performance of the 21-mm sorin bicarbon mechanical aortic prostheses using ...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Optics express     Volume:  20     ISSN:  1094-4087     ISO Abbreviation:  Opt Express     Publication Date:  2012 Jun 
Date Detail:
Created Date:  2012-06-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101137103     Medline TA:  Opt Express     Country:  United States    
Other Details:
Languages:  eng     Pagination:  14573-83     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Tandem organic light-emitting diodes with KBH<sub>4</sub> doped 9,10-bis(3-(pyridin-3-yl)phenyl) ant...
Next Document:  Sensitive metal layer assisted guided mode resonance biosensor with a spectrum inversed response and...