Microsnare-assisted mechanical removal of intraprocedural distal middle cerebral arterial thromboembolism.
MedLine Citation:
PMID:  12695193     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Thromboembolic events are potential complications of neurointerventional procedures. The mainstay of therapy for these complications is both supportive therapy and the use of fibrinolytic agents. In some cases, the occluding clot seems to be resistant to fibrinolytic or anti-platelet agents. We herein report our successful attempt at clot removal by using a microsnare to mechanically capture and remove a small resistant organized clot fragment that was occluding one of the post-trifurcation M2 divisions of a middle cerebral artery. This complication occurred during coil embolization of an ipsilateral posterior communicating aneurysm.
Authors:
Pieter Fourie; Ian C Duncan
Related Documents :
18302643 - Endovascular trapping of a vertebral artery segment to control pica origin tearing.
9539493 - Mechanical recanalization of total coronary occlusions with the use of a new guide wire.
847793 - Implanted device for middle cerebral artery occlusion in conscious cats.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  AJNR. American journal of neuroradiology     Volume:  24     ISSN:  0195-6108     ISO Abbreviation:  AJNR Am J Neuroradiol     Publication Date:  2003 Apr 
Date Detail:
Created Date:  2003-04-15     Completed Date:  2003-07-28     Revised Date:  2013-05-24    
Medline Journal Info:
Nlm Unique ID:  8003708     Medline TA:  AJNR Am J Neuroradiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  630-2     Citation Subset:  IM    
Affiliation:
Unitas Interventional Unit, Unitas Hospital, Lyttleton, South Africa.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Balloon / instrumentation*
Antibodies, Monoclonal / administration & dosage
Cerebral Angiography*
Embolization, Therapeutic / instrumentation*
Equipment Design
Female
Humans
Immunoglobulin Fab Fragments / administration & dosage
Infarction, Middle Cerebral Artery / radiography,  therapy*
Intracranial Aneurysm / radiography,  therapy*
Middle Aged
Prostheses and Implants*
Retreatment
Thrombectomy / instrumentation*
Thrombolytic Therapy / instrumentation
Chemical
Reg. No./Substance:
0/Antibodies, Monoclonal; 0/Immunoglobulin Fab Fragments; X85G7936GV/abciximab

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  MR-guided catheter navigation of the intracranial subarachnoid space.
Next Document:  Differentiation of toxoplasmosis and lymphoma in AIDS patients by using apparent diffusion coefficie...