Document Detail


Methodological considerations for using inductive sensors (3SPACE ISOTRAK) to monitor 3-D orthopaedic joint motion.
MedLine Citation:
PMID:  11415693     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: To assess and improve methodological constraints of the 3SPACE ISOTRAK. DESIGN: Several data sets were used to evaluate the following constraints: the performance is adversely affected by close proximity of metallic objects or electromagnetic fields; the3SPACE field contaminates electromyography recordings; and cross-talk from one axis to the other two occurs if the Euler rotation sequence is not matched to the orthopaedic description and function of the joint in question. BACKGROUND: The 3SPACE ISOTRAK is one of the few instruments suitable for measurement of relative three-dimensional joint rotation, however several methodological constraints exist. RESULTS AND CONCLUSIONS: Generally, accuracy can be maintained by restricting offending objects from the sensitive zone between the transmitter and sensor and using long leads to afford the subject distance from computers and other electrical instrumentation; while contamination of EMG amplitude in the time domain can be minimized by using quality instrumentation, and on occasion modifying electrode orientation. Contamination of the EMG frequency content appears unavoidable at low levels of muscle contraction; and cross-talk between axes is minimized by matching the first Euler rotation with the axis of the joint that is characterized by the greatest expected angular displacement. RELEVANCE: The 3SPACE ISOTRAK is one of the few instruments available that is suitable for measuring three axes of relative joint motion (local joint axes that rotate with the joint -- not global). This paper suggests several techniques to increase the accuracy and viability of this instrument.
Authors:
S M McGill; J Cholewicki; J P Peach
Related Documents :
1562913 - The organization of stepping in patients with parkinson's disease: bradykinesia or disc...
14733343 - Kinematic changes after fusion and total replacement of the ankle: part 3: talar movement.
12714673 - Retinal spectral sensitivity, fur coloration, and urine reflectance in the genus octodo...
Publication Detail:
Type:  JOURNAL ARTICLE    
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  12     ISSN:  1879-1271     ISO Abbreviation:  Clin Biomech (Bristol, Avon)     Publication Date:  1997 Apr 
Date Detail:
Created Date:  2001-Jun-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  190-194     Citation Subset:  -    
Affiliation:
Occupational Biomechanics and Safety Laboratories, Department of Kinesiology, Faculty of Applied Health Sciences, University of Waterloo, ON, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A non-invasive protocol for the determination of lumbosacral vertebral angle.
Next Document:  In vitro and in vivo radiomorphometric analyses of distal screw hole position of the solid tibial na...