Document Detail


Metal allergy to stainless steel wire after coronary artery bypass grafting.
MedLine Citation:
PMID:  14598128     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
To our knowledge, this is the first reported case of a manganese metal allergy to stainless steel wire. A 51-year-old man suffered from a refractory pruritic erythematous wheal after the insertion of a stainless steel wire. The patch test showed strong reactions to manganese, one of the constituents of stainless steel wire. After the removal of all stainless steel wires, the symptoms were much improved, except for mild pruritus on his face.
Authors:
Kenji Takazawa; Noboru Ishikawa; Hiroyuki Miyagawa; Taira Yamamoto; Akifusa Hariya; Shizuyuki Dohi
Related Documents :
3383138 - Localized isolated angiitis of the central nervous system associated with primary intra...
6985778 - Percutaneous cervical central venous line placement: a comparison of the internal and e...
21353688 - Agenesis of the infrarenal inferior vena cava with thrombosis of the renal vein in a fe...
11495878 - Confirmation of internal jugular guide wire position utilizing transesophageal echocard...
22483418 - Radial artery pulse wave analysis for non-invasive assessment of coronary artery disease.
2703298 - Cellular glycoproteins correlating with pulmonary-colonizing potential in b16 melanoma.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs     Volume:  6     ISSN:  1434-7229     ISO Abbreviation:  J Artif Organs     Publication Date:  2003  
Date Detail:
Created Date:  2003-11-04     Completed Date:  2004-01-05     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9815648     Medline TA:  J Artif Organs     Country:  Japan    
Other Details:
Languages:  eng     Pagination:  71-2     Citation Subset:  IM    
Affiliation:
Juntendo University, Department of Cardiothoracic Surgery, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan. kentakaz@med.juntendo.ac.jp
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Bone Wires / adverse effects*
Coronary Artery Bypass / adverse effects*
Device Removal
Humans
Hypersensitivity / etiology*
Male
Manganese / adverse effects*
Middle Aged
Stainless Steel / adverse effects*
Sternum / surgery*
Treatment Outcome
Chemical
Reg. No./Substance:
12597-68-1/Stainless Steel; 7439-96-5/Manganese