Mechanical support for postcardiotomy heart failure.
MedLine Citation:
PMID:  2980017     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Cardiac failure remains a life-threatening complication for certain patients undergoing intracardiac repair. Despite improvements in surgical techniques, methods of myocardial protection, and postoperative care, patients are frequently at risk to develop postoperative low output syndrome. Approximately 1% of cardiac surgical patients cannot be weaned from extracorporeal circulation in spite of adequate volume loading, the use of inotropic support, and initiation of intraaortic balloon pumping. In these cases, ventricular assist devices (VAD) can mechanically aid the failing heart and reverse the low output state. The concept of mechanical support for the failing left ventricle was first proposed by Clauss et al. in 1961. By 1968, Kantrowitz and associates had developed and refined the first intraaortic balloon pump (IABP). Through the efforts of Moulopolous and others, this device evolved into the present-day intraaortic balloon pump (IABP). Clinical evidence for the efficacy of left ventricular assist devices (LVAD) remained questionable until 1980, when the National Heart, Blood and Lung Institute evaluated short-term LVADs by comparing various types of mechanical aids. This report focused attention primarily on the failing left ventricle (LV). As the use of inotropic support, intraaortic balloon pumping, and LVADs improved, a small group of patients emerged who could not be separated from extracorporeal circulation due to a failing right ventricle. The failing right ventricle emerged as a unique clinical entity similar to postcardiotomy left ventricular failure that also benefited from mechanical cardiac assistance. Current therapy at major centers incorporating mechanical assist devices is based on the premise that the low output state will allow the failing heart to recover from a reversible injury. The frequent occurrence of postcardiotomy ischemia may be due to several factors such as poor myocardial protection, overdistension of the LV, emboli, coronary spasm or technical problems. Whatever the etiology, the end product of cardiac failure is a demand for oxygen consumption that cannot be met, thus leading to cardiac demise.
Authors:
C D Campbell; D J Tolitano; K T Weber; P M Statler; R L Replogle
Related Documents :
20883387 - Japanese guidance for ventricular assist devices/total artificial hearts.
12928207 - Ventricular reshaping with devices.
17613407 - Persistence of cheyne-stokes breathing after left ventricular assist device implantatio...
20228327 - Ct of left ventricular assist devices.
8604407 - Risk stratification after acute myocardial infarction: which studies are best?
8051787 - A case of creatine kinase isomer anomaly in relation to the diagnosis of acute myocardi...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of cardiac surgery     Volume:  3     ISSN:  0886-0440     ISO Abbreviation:  J Card Surg     Publication Date:  1988 Sep 
Date Detail:
Created Date:  1992-04-09     Completed Date:  1992-04-09     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  8908809     Medline TA:  J Card Surg     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  181-91     Citation Subset:  IM    
Affiliation:
Department of Surgery, Michael Reese Hospital and Medical Center, Chicago, Illinois 60616.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Academic Medical Centers
Adult
Aged
Cardiac Output, Low / etiology,  mortality,  therapy*
Cardiac Surgical Procedures / adverse effects*
Clinical Protocols / standards
Follow-Up Studies
Heart-Assist Devices / standards*
Humans
Illinois / epidemiology
Intra-Aortic Balloon Pumping / standards*
Middle Aged
Postoperative Complications / etiology,  mortality,  therapy*
Survival Rate

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Surgical treatment of ascending aortic pathology.
Next Document:  Clinical experience with expanded polytetrafluoroethylene Gore-Tex surgical membrane for pericardial...