Abstract/OtherAbstract:
BACKGROUND: The aim of this study was to evaluate early and late outcomes after mechanical systemic heart valve replacement in pediatric patients. METHODS: Between October 1981 and December 2003, 32 children (mean age 7.2 +/- 5.4 years; 4 months - 15.9 years) underwent mechanical mitral (MVR, n = 17), aortic (AVR, n = 13) or double valve replacement (DVR, n = 2) with St. Jude Medical valves. Twenty-two patients (69 %) had undergone previous cardiac surgery. Anticoagulation self-management was used since 1995. RESULTS: The operative mortality was 3.1 %. Perioperative complications were complete heart block (n = 5), ventricular fibrillation (n = 1) and myocardial infarction (n = 1) and were exclusively related to patients with MVR. Mean calculated valve size ratio (geometric prosthesis orifice area/normal valve size area) was 1.72 (1.07 - 2.85) for AVR and 1.4 (0.88 - 3.12) for MVR. Mean follow-up was 9.1 +/- 6.6 years (range 0.4 - 23.2 years, cumulative 283 patient-years). There were two late deaths in patients with MVR. Actuarial survival after 10 years was 93.8 %. Late complications were endocarditis (n = 2), minor hemorrhagic event (n = 1), and stroke (n = 1). Anticoagulation self-management is well accepted by all patients/parents. Overall 10-year freedom from any anticoagulation-related adverse event with phenprocoumon was 89.1 % (1.2 %/patient year). Nine patients required reoperations: redo-MVR (outgrowth of prostheses (n = 3), pannus overgrowth (n = 2), closure of paravalvular leak after AVR (n = 2), partial aortic valve thrombosis (n = 1) and redo-DVR (n = 1 for endocarditis). Freedom from reoperation after 10 years was 80.9 %. CONCLUSIONS: Mechanical valve prostheses are a valuable option for left-sided heart valve replacement in pediatric patients. Perioperative morbidity was exclusively related to patients with MVR. Oversizing was often possible to avoid early reoperation for outgrowth. The operative mortality and long-term morbidity are acceptable. Anticoagulation self-management is safe and well accepted.
Authors:
J S Sachweh; A R Tiete; E G Mühler; J Groetzner; H Gulbins; B J Messmer; S H Daebritz
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Thoracic and cardiovascular surgeon     Volume:  55     ISSN:  0171-6425     ISO Abbreviation:  Thorac Cardiovasc Surg     Publication Date:  2007 Apr 
Date Detail:
Created Date:  2007-04-05     Completed Date:  2007-06-14     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7903387     Medline TA:  Thorac Cardiovasc Surg     Country:  Germany    
Other Details:
Languages:  eng     Pagination:  156-62     Citation Subset:  IM    
Affiliation:
Department of Thoracic and Cardiovascular Surgery, Pediatric Cardiac Surgery, RWTH Aachen University Hospital, Aachen, Germany. jsachweh@ukaachen.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Actuarial Analysis
Adolescent
Anticoagulants / adverse effects
Aortic Valve*
Child
Child, Preschool
Female
Follow-Up Studies
Heart Valve Diseases / surgery*
Heart Valve Prosthesis Implantation* / adverse effects,  instrumentation,  mortality
Humans
Infant
Male
Mitral Valve*
Postoperative Hemorrhage / etiology
Prosthesis Failure
Reoperation
Thromboembolism / etiology
Treatment Outcome