Mechanical properties of open-cell, self-expandable shape memory alloy carotid stents.
MedLine Citation:
PMID:  20497165     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
Mechanical properties of carotid stents are important for the selection of the implantable device. The efficacy of cell design is usually investigated on the basis of clinical follow-ups; however, for the specific carotid application the relative importance of the cell design on the stenting outcome is debated. Ideally, a carotid stent should have at the same time low bending stiffness (i.e., high flexibility) to correctly conform to the vessel curvatures in the stenotic region and high stiffness to sustain the vessel wall in the radial direction. In this study, experimental tests on six carotid open-cell design self-expandable stents were carried out to assess bending and radial stiffness. A four-point bending test was adopted to measure the bending stiffness. Radial stiffness was obtained by measuring the stent resistance to local compression in a V-shaped support. Geometrical features, such as the link positioning and their length, were examined as a possible determinant of the mechanical properties of the tested stents. The tested stents showed very different geometrical features and mechanical properties despite similar material and a common open-cell structure consisting in rings connected by roughly straight links. In particular, different strategies are evident regarding the link position. Three distinct behaviors were observed: stents with both low radial and bending stiffness, moderate bending and high radial stiffness, and high bending and moderate radial stiffness. In general, a large link length allows the stent to be more flexible under bending condition, whereas the mutual links positioning plays a key role in the radial stiffness of these devices. Furthermore, for a fixed strut layout, a correlation was found between the strut cross area, as well as metal-to-artery ratio and the resultant radial and bending stiffness.
Authors:
Davide Carnelli; Giancarlo Pennati; Tomaso Villa; Luigi Baglioni; Bernhard Reimers; Francesco Migliavacca
Related Documents :
20003685 - Recanalization of symptomatic carotid artery dissections causing occlusion with multipl...
12074435 - The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms.
20093945 - Multiple mguard stent implantation to treat massive right coronary artery dissection du...
16863805 - Fractured and embolized coronary stent mimicking significant internal carotid stenosis.
2727645 - The internal mammary artery origin flap aortoplasty in coarctation of the aorta.
24418205 - Growth of diminutive central pulmonary arteries after right ventricle to pulmonary arte...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Artificial organs     Volume:  35     ISSN:  1525-1594     ISO Abbreviation:  Artif Organs     Publication Date:  2011 Jan 
Date Detail:
Created Date:  2011-01-13     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  United States    
Other Details:
Languages:  eng     Pagination:  74-80     Citation Subset:  IM    
Copyright Information:
© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Affiliation:
Laboratory of Biological Structure Mechanics, Department of Structural Engineering, Politecnico di Milano, Milano, Italy. carnelli@stru.polimi.it
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Physiologic Benefits of Pulsatile Perfusion During Mechanical Circulatory Support for the Treatment ...
Next Document:  Reflections on 'autistic integrity'.