Measuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease.
MedLine Citation:
PMID:  20872815     Owner:  NLM     Status:  In-Process    
Lung function measurement is difficult in unsedated infants; tidal breathing parameters are a useful non-invasive surrogate, but even these measurements cause disturbance from applying a facemask. We investigated a novel volumetric vest system (FloRight), which measures volume changes of the respiratory system from changes in the magnetic fields induced by current-carrying coils around the entire chest and abdomen. Using a facemask and ultrasonic flowmeter as comparator, we assessed the validity and repeatability of tidal breathing parameters measured by FloRight in 10 healthy newborn infants during natural sleep. We also assessed the effect of a facemask on tidal volume and tidal expiratory flow parameters. To assess the ability of the FloRight system to detect disease, we compared the healthy infants with 11 infants suffering from bronchopulmonary dysplasia. Tidal parameters with the FloRight vest corresponded closely with facemask measurements. Mean difference, mask minus vest, for tidal volume was 0.096 ml (P < 0.05), with limits of agreement +4.5 to -4.3 ml. Coefficient of repeatability was similar for mask and vest measurements. Tidal volume measured by FloRight with mask in place (20.6 ml) was significantly higher than without mask (16.1 ml), but tidal expiratory flow parameters were not altered. FloRight measurements of tidal parameters were markedly different between the two groups of infants, with tidal volume per Kg significantly higher and tidal expiratory flow parameters significantly lower. Our findings suggest that the FloRight system is able to measure tidal breathing parameters accurately, in healthy newborn infants, without prior calibration on the infant. It appears to have at least sufficient sensitivity to detect severe respiratory disease.
C Olden; E Symes; P Seddon
Related Documents :
471595 - The labeling of lung phosphatidylcholine in premature rabbits.
6703485 - Muscle pressure and flow during expiration in infants.
1952425 - Bronchial responsiveness and lung function in recurrently wheezy infants.
12904325 - Progressive decline in plethysmographic lung volumes in infants: physiology or technology?
3790105 - Bile acids in the serum and duodenal content of newborn infants of different classifica...
7136655 - Low reserve albumin for binding of bilirubin in neonates with deficiency of bilirubin e...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Pediatric pulmonology     Volume:  45     ISSN:  1099-0496     ISO Abbreviation:  Pediatr. Pulmonol.     Publication Date:  2010 Nov 
Date Detail:
Created Date:  2010-10-27     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8510590     Medline TA:  Pediatr Pulmonol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1070-5     Citation Subset:  IM    
Respiratory Research Unit, Royal Alexandra Children's Hospital, Brighton BN2 5BE, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Is surgical resection justified for stage IV colorectal cancer patients having bilobar hepatic metas...
Next Document:  Stability of Pycnogenol® as an ingredient in fruit juices subjected to in vitro gastrointestinal di...