Document Detail


Measurements of the relative output factors for CyberKnife collimators.
MedLine Citation:
PMID:  14683553     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To determine accurately the relative output factors, defined as the ratio of the nominal dose rate for a given collimator to that of the 60-mm collimator. This is particularly important for radiosurgical treatment of functional disorders, such as trigeminal neuralgia, in which a single large radiation dose is delivered to the target with a small collimator, such as the 5-mm collimator for CyberKnife radiosurgery. Numerous studies on the output factors have been reported for the Leksell gamma knife unit but none for the CyberKnife system. METHODS: Measurements of the relative output factors for all 12 collimators were performed by three different methods: silicon diode, radiographic film, and thermoluminescent dosimetry microcubes. The silicon diode is designed for measurements in small (1-50 MV) photon beams performed in water or air. Film and thermoluminescent dosimetry measurements were performed in a plastic phantom. RESULTS: The measured relative output factors for the three methods were very similar except for the three smallest collimators (5, 7.5, and 10 mm). The measured difference between the above methods was approximately 2%. The mean value of the output factor for the 5-mm collimator was 0.686 +/- 0.024. The uncertainties of the output factors are expected to increase with the decrease of collimator diameter. They range from approximately 1 to 4% of the relative output factor. CONCLUSION: The relative output factor can be measured with an acceptable accuracy even for the smallest (5-mm) CyberKnife collimators. This requires the selection of appropriate dosimetric detectors and measuring procedures. The results obtained with the diode are considered more accurate than with the other two methods.
Authors:
Cheng Yu; Gabor Jozsef; Michael L J Apuzzo; Zbigniew Petrovich
Related Documents :
22603 - Estimation of the degree of crystallinity in digoxin by x-ray and infrared methods.
10360243 - Heart rate monitoring as a field method for estimating energy expenditure as evaluated ...
9796143 - Variability of hydroxyapatite-coated dental implants.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Neurosurgery     Volume:  54     ISSN:  0148-396X     ISO Abbreviation:  Neurosurgery     Publication Date:  2004 Jan 
Date Detail:
Created Date:  2003-12-19     Completed Date:  2004-03-11     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7802914     Medline TA:  Neurosurgery     Country:  United States    
Other Details:
Languages:  eng     Pagination:  157-61; discussion 161-2     Citation Subset:  IM    
Affiliation:
Department of Radiation Oncology, Keck School of Medicine, University of Southern California, Los Angeles, California 90033, USA. chengyu@usc.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Film Dosimetry*
Humans
Phantoms, Imaging
Radiosurgery / instrumentation*
Radiotherapy Dosage
Silicon*
Thermoluminescent Dosimetry*
Chemical
Reg. No./Substance:
7440-21-3/Silicon

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  De novo neurogenesis and acute stroke: are exogenous stem cells really necessary?
Next Document:  Perinidal dilated capillary networks in cerebral arteriovenous malformations.