Measurement of tissue oxygen tension: comparison between two subcutaneous oxygen tonometers.
MedLine Citation:
PMID:  1890444     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We compared the 95% response time (95% RT) of two tissue oxygen tonometers under two sets of circumstances. We first evaluated the devices during normoxia, hyperoxia, and anoxia in vitro, using a transcutaneous PO2 electrode (PtcO2) as the reference. The responses to normoxia and to different grades of hyperoxia were examined in vivo in 8 healthy volunteers to assess the relationship between changes in subcutaneous PO2 and PtcO2, an estimate of arterial PO2 (PaO2). One subcutaneous method (ScA) used a technique based on a polarographic needle electrode in situ connected to an ammeter; the second method (ScB) was based on a blood gas analyzer system first described by Hunt (Lancet 164;2:1370). ScA and PtcO2 both responded to stepwise changes in ambient oxygen concentration (21-100%) in vitro within 10 seconds; the 95% RT of ScA was 1.39 +/- 0.5 to 2.39 +/- 0.8 minutes and that of PtcO2 was 0.32 +/- 0.1 to 0.49 +/- 0.1 minutes. ScB had a lag of 3 minutes, and the 95% RT was 6.75 +/- 0.5 to 8.2 +/- 0.8 minutes. In contrast to the results in vitro, the response of ScA to changes in FiO2 in vivo was delayed compared with the rapid response of PtcO2, reflecting the physiologic delay of tissue PO2 in response to increased PaO2. The time lag and the long 95% RT of ScB were even more evident in vivo. ScA reacted three to four times faster than ScB, both in vitro and in vivo, to changes in the oxygen environment. The in vitro 95% RT of ScA to changes in ambient oxygen varied from 2 to 3.5 minutes.(ABSTRACT TRUNCATED AT 250 WORDS)
Authors:
H O Soini; J Takala
Related Documents :
19948524 - Regional tissue oxygenation in association with duration of hypoxaemia and haemodynamic...
17490904 - The effect of adrenaline and high ca2+ on the mechanical performance and oxygen consump...
10692114 - The transepidermal oxygen flux from the environment is in balance with the capillary ox...
11977294 - The influence of glucose-insulin-kalium mixture (gik) on the selected parameters of aci...
18608444 - Effects of alignment on interface pressure for transtibial amputee during walking.
3753694 - Evolution of the visual prognosis of prematures in the last 20 years.
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Journal of clinical monitoring     Volume:  7     ISSN:  0748-1977     ISO Abbreviation:  J Clin Monit     Publication Date:  1991 Jul 
Date Detail:
Created Date:  1991-10-17     Completed Date:  1991-10-17     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8506707     Medline TA:  J Clin Monit     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  227-31     Citation Subset:  IM    
Affiliation:
Department of Intensive Care, Kuopio University Central Hospital, Finland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Anoxia / blood
Blood Gas Monitoring, Transcutaneous / instrumentation*
Humans
Oxygen / blood
Reference Values
Chemical
Reg. No./Substance:
7782-44-7/Oxygen

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Evaluating the human engineering of microprocessor-controlled operating room devices.
Next Document:  Auscultation cannot distinguish esophageal from tracheal passage of tube.