Document Detail


Measurement of right atrial oxygen saturation by fiberoptic oximetry accurately reflects mixed venous oxygen saturation in swine.
MedLine Citation:
PMID:  3373256     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Continuous fiberoptic measurement of mixed venous oxygen saturation (SvO2) via a pulmonary artery catheter is a useful, though invasive, monitoring technique. Continuous right atrial venous oxygen saturation measurement by oximetry offers the potential of a significantly less invasive SvO2 measurement. However, catheter motion, character of the vessel, chamber wall reflection, the filtering technique involved in calculating oxygen saturation, and the streaming of venous blood prior to ventricular mixing may influence the feasibility of continuous right atrial (RA) SvO2 measurement. This study investigated the performance of fiberoptically measured RA SvO2, at a position 2 cm from the tricuspid valve, relative to simultaneously measured pulmonary artery (PA) SvO2. Ten pigs were subjected to circulatory shock or chemically induced lung damage. Over a total monitoring period of approximately 40 hours, 464 paired data points were sampled at 5-minute intervals. The difference between the overall means of RA and PA SvO2 was 0.91% with a standard error of the estimate of 4.7%, a regression equation of RA SvO2 = PA SvO2 (0.94 + 2.1) PA So2, and a correlation coefficient of 0.94. Our conclusion, although extrapolated from a pig model, is that fiberoptic SvO2 monitoring may be accomplished less invasively and at a lower cost with a right atrial catheter.
Authors:
G G Davies; J Mendenhall; T Symreng
Related Documents :
24161006 - Problem solving with pentagons: tsai-type quasicrystal as a structural response to chem...
19991176 - Respiration in high flying: (united services section).
1655346 - Zinc improves the filterability of sickle erythrocytes at intermediate oxygen partial p...
8314636 - Measurement of oxygen consumption and arterial-venous oxygen saturation following total...
25134436 - Simple finite element models for use in the design of therapeutic footwear.
24942996 - Exploring differences in prevalence of diagnosed, measured and undiagnosed hypertension...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of clinical monitoring     Volume:  4     ISSN:  0748-1977     ISO Abbreviation:  J Clin Monit     Publication Date:  1988 Apr 
Date Detail:
Created Date:  1988-06-30     Completed Date:  1988-06-30     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  8506707     Medline TA:  J Clin Monit     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  99-102     Citation Subset:  IM    
Affiliation:
Department of Anesthesia, University of Iowa College of Medicine, Iowa City 52242.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Catheters, Indwelling
Fiber Optic Technology
Heart Atria
Heart Catheterization / instrumentation
Monitoring, Physiologic / instrumentation*
Oximetry / instrumentation*
Oxygen / blood
Pulmonary Artery
Regression Analysis
Swine
Chemical
Reg. No./Substance:
7782-44-7/Oxygen

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Transorally obtained oxygen tension as an indicator of arterial oxygen tension.
Next Document:  Astrocytoma in children: 14 years' experience at Stanford University Medical Center.