Document Detail


Measurement of lower limb volume: Agreement between the vertically oriented perometer and a tape measure method.
MedLine Citation:
PMID:  23351956     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: To investigate the agreement between lower limb volume measurements for the vertically oriented perometer and a tape measure method. DESIGN: Between-methods agreement and test-retest reliability study. SETTING: University setting. PARTICIPANTS: Thirty university staff and students were recruited using convenience sampling with no participant drop-outs. INTERVENTIONS: All participants' dominant lower limb volumes were measured using the vertically oriented perometer and a tape measure method. MAIN OUTCOME MEASURES: The Bland-Altman difference plot was reported for determining the bias between the two methods and its 95% confidence interval. Test-retest reliability and the measurement error for the perometer method were determined using the ICC(2,1) model and within-subject standard deviation (s(w)) respectively. RESULTS: There was a lack of agreement between the tape measure and perometer method. The Bland-Altman difference plot showed that the tape measure method overestimated limb volume by 157ml compared to the perometer method. A 95% confidence interval of -834ml to 519ml was observed. The test-retest reliability of the perometer method was ICC(2,1)=0.99. The measurement error of the perometer method was clinically acceptable (s(w)=121ml). CONCLUSIONS: There was a lack of agreement between the two methods investigated. Therefore the perometer and tape measure methods are not interchangeable. It is recommended that future validity and reliability studies for the vertically oriented perometer are conducted on clinical populations.
Authors:
Chee-Wee Tan; Fiona Coutts; Cathy Bulley
Related Documents :
23220776 - Statistical process control analysis for patient-specific imrt and vmat qa.
24672616 - Visual estimation of bedside echocardiographic ejection fraction by emergency physicians.
20545716 - Root caries risk indicators: a systematic review of risk models.
24326316 - Coincidence summing corrections for volume samples using the penelope/peneasy monte car...
12176276 - The influence of operational variables on mean size and size distribution of spheroids ...
24187436 - Hypoglycemia early alarm systems based on multivariable models.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-22
Journal Detail:
Title:  Physiotherapy     Volume:  -     ISSN:  1873-1465     ISO Abbreviation:  Physiotherapy     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401223     Medline TA:  Physiotherapy     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Affiliation:
From the School of Health Sciences, Queen Margaret University Edinburgh, United Kingdom. Electronic address: ctan@qmu.ac.uk.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A comparison of the mechanical properties of a modified silorane based dental composite with those o...
Next Document:  Antifertility activity of methanolic bark extract of Aegle marmelos (l.) in male wistar rats.