Document Detail


Measurement of dabigatran and rivaroxaban in primary prevention of venous thromboembolism in 106 patients, who have undergone major orthopedic surgery: an observational study.
MedLine Citation:
PMID:  23335022     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
No routine coagulation laboratory test is recommended during rivaroxaban or dabigatran treatment. However measuring drug concentration and/or anticoagulant activity can be desirable in some special clinical settings, such as bleeding, thrombosis recurrence or emergency surgery. The effects of dabigatran etexilate and rivaroxaban on various coagulation assays have been previously studied in normal plasma spiked with increasing concentrations of the drug. In contrast, few data are available in routinely treated patients. In order to perform and to interpret the results of these tests, it is necessary to determine the usual responses of patient's plasma. We have used several coagulation tests in a prospective study including 106 patients receiving thromboprophylactic treatment with dabigatran 150 or 220 mg od and rivaroxaban 10 mg od for major orthopaedic surgery. The most common tests-prothrombin time (PT) and activated partial thromboplastin time (aPTT)-give results, which vary according to the reagent used. To overcome this limitation, we advocate the use of plasma calibrators, which decreases the inter-laboratory heterogeneity of results. Anti-Xa measurement and Hemoclot, a thrombin diluted clotting assay, are specific assays which have been proposed for rivaroxaban and dabigatran respectively. These tests, conventional PT, aPTT and thrombin generation (TG) have been performed. We demonstrated that measurements of both drugs can determine reliably the drug concentration in patients' plasmas. PT is more prolonged with rivaroxaban than with dabigatran. Interestingly, the pattern of TG was clearly different in relation to the difference in the mechanism of action of the two new anticoagulants. A significant inter-individual variability of response is detected. Rivaroxaban-mean Cmax 140 ng/mL (extremes 0-412) induces a greater increase of PT than dabigatran. aPTT is sensitive to dabigatran. Rivaroxaban concentrations were in good agreement with two other studies while unexplained lower than expected concentrations were found in dabigatran patients receiving 220 mg once a day [mean Cmax 60 ng/mL (extremes 0-320)]. An interference by pantoprazole, a drug which reduces dabigatran absorption, could explain the observed lower than expected results.
Authors:
Meyer Michel Samama; Céline Guinet; Léna Le Flem; Emmanuel Ninin; Jean-Marc Debue
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of thrombosis and thrombolysis     Volume:  35     ISSN:  1573-742X     ISO Abbreviation:  J. Thromb. Thrombolysis     Publication Date:  2013 Feb 
Date Detail:
Created Date:  2013-01-21     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9502018     Medline TA:  J Thromb Thrombolysis     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  140-6     Citation Subset:  IM    
Affiliation:
Cochin-Broca-Hôtel Dieu University Hospital, Paris, France, meyermichel.samama@biomnis.com.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Improving the reuse of computational models through version control.
Next Document:  Trifolium pallidum and Trifolium scabrum extracts in the protection of human plasma components.