Measurement of atrial septal defect size: a comparative study between three-dimensional transesophageal echocardiography and the standard balloon sizing methods.
MedLine Citation:
PMID:  10982709     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Atrial septal defect (ASD) size measurement is of paramount importance for the successful deployment of a transcatheter septal occluder. The stretched balloon diameter (SBD) has long been regarded as the gold standard for selection of the size of any device. Three-dimensional (3-D) transesophageal echocardiography (TEE) can visualize the overall structure of the atrial septum, therefore rendering an accurate size of the ASD. In this study we aimed to validate the accuracy of ASD size measurement by 3-D TEE and to elucidate the reason for the difference between balloon sizing and 3-D measurement. Forty-one consecutive patients were enrolled in this protocol for ASD device closure using the Amplatzer septal occluder. Thirty-nine patients were diagnosed by 2-D transthoracic echocardiography as secundum ASD and 2 patients were diagnosed as patent foramen ovale. Two measurements of the balloon size were sequentially obtained by 2-D TEE after the balloon was fully inflated in the left atrium. First, no residual shunt across the septum could be seen while the balloon was pulled back against the septum. This measurement was called the balloon occlusive diameter (BOD). Second, with balloon deflation, a slight deformity of the balloon was seen just prior to its popping through the septum. This measurement was called the stretched balloon diameter (SBD). Three-dimensional TEE was performed in all patients at the beginning of the procedure before device deployment and within 15 minutes after device release. Three-dimensional TEE provided superior views of the ASDs, showing the spatial relationship between the ASD and the neighboring structures. For maximal ASD size measurement, balloon sizing was larger than 3-D TEE examination, whereas 2-D was smaller than the other two methods. The best correlation was found between 3-D TEE measurements and the BOD (r = 0.98, p < 0.0001). Three-dimensional TEE provides en face view of ASD; thus, it can accurately measure the size of ASD. Three-dimensional TEE measurement of ASD can be used instead of balloon sizing for the selection of transcatheter ASD occluder size.
Authors:
W Zhu; Q L Cao; J Rhodes; Z M Hijazi
Related Documents :
8974809 - Unsuccessful deflation of a bifoil balloon during percutaneous mitral valvuloplasty.
1606609 - Rotational ablation of coronary artery lesions using single, large burrs.
3488719 - Spinal cord infarction following intraaortic balloon support.
8992869 - Cardiovascular abnormalities in noonan syndrome: the clinical findings and treatments.
2146039 - Iliofemoral arterial complications of balloon angioplasty for systemic obstructions in ...
15347209 - Use of a large angioplasty balloon for predilation is a risk factor for embolic complic...
7579969 - A new technique for performing mitral valve repair in a small left atrium.
19396389 - Portal vein branching pattern in anomalous right-sided round ligament.
14656189 - Transient ischemic attack due to early carotid stent thrombosis: successful rescue with...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article    
Journal Detail:
Title:  Pediatric cardiology     Volume:  21     ISSN:  0172-0643     ISO Abbreviation:  Pediatr Cardiol     Publication Date:    2000 Sep-Oct
Date Detail:
Created Date:  2000-12-15     Completed Date:  2001-01-04     Revised Date:  2008-02-20    
Medline Journal Info:
Nlm Unique ID:  8003849     Medline TA:  Pediatr Cardiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  465-9     Citation Subset:  IM    
Affiliation:
Department of Pediatrics, Floating Hospital for Children at New England Medical Center and Tufts University School of Medicine, Boston, MA 02111, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Aged
Balloon Dilatation
Child
Child, Preschool
Echocardiography, Three-Dimensional*
Echocardiography, Transesophageal*
Fluoroscopy
Heart Catheterization
Heart Septal Defects, Atrial / ultrasonography*
Humans
Linear Models
Middle Aged
Observer Variation

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine