Measurement of angioplasty lumen volume and wall compliance: a laboratory study.
MedLine Citation:
PMID:  9046535     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We have developed a device and technique for measuring the pressure-volume characteristics of an arterial segment from a standard angioplasty balloon, enabling us in this laboratory study to investigate the ability of the technique to measure changes in lumen volume and wall compliance. Percutaneous transluminal coronary angioplasty (PTCA) is a valuable clinical procedure for alleviating arterial stenosis, but the long-term success of the technique is less than ideal. The ability to monitor the effect of the balloon on the artery during inflations could lead to improvements in the technique. In this study, 10 different lumen diameters (1.6 to 3.4 mm) were produced in a Perspex block, and six different wall compliances produced with silicone tubes of constant inner diameter (2.0 mm) but different outer diameters (3.5 to 6.0 mm) A standard PTCA balloon was inflated under automatic control at a constant rate of 0.05 ml s-1 to 800 kPa (8 bar). Pressure and volume data were recorded to computer continuously throughout the procedure. Differences in lumen volume of +/-0.01 ml and wall compliance of +/-5% could be differentiated with greater than 95% confidence. We conclude that our technique allows small changes in lumen volume and wall compliance to be differentiated using a standard angioplasty catheter and balloon.
Authors:
A Murray; V Allen
Related Documents :
9403425 - Comparison of primary coronary angioplasty and intravenous thrombolytic therapy for acu...
1756565 - Variations in blood supply to the anterior interventricular septum: incidence and possi...
2945575 - Influence of a variant angina on the results of percutaneous transluminal coronary angi...
16374145 - Safety of single versus multi-vessel angioplasty for patients with acute myocardial inf...
18394025 - Nitric oxide depresses connexin 43 after myocardial infarction in mice.
542825 - Elevated mid-myocardial oxygen tension in the fibrillating heart during cardiopulmonary...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Physiological measurement     Volume:  18     ISSN:  0967-3334     ISO Abbreviation:  Physiol Meas     Publication Date:  1997 Feb 
Date Detail:
Created Date:  1997-06-13     Completed Date:  1997-06-13     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  39-47     Citation Subset:  IM    
Affiliation:
Regional Medical Physics Department, Freeman Hospital, Newcastle-upon-Tyne, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Transluminal, Percutaneous Coronary*
Automation
Coronary Disease / physiopathology*,  therapy*
Coronary Vessels / physiopathology*
Humans
Models, Theoretical*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Intraventricular electrogram mapping and radiofrequency cardiac ablation for ventricular tachycardia...
Next Document:  A continuous patient activity monitor: validation and relation to disability.