Abstract/OtherAbstract:
The reference bladder dose for gynaecological intracavitary brachytherapy (BT), as defined by the ICRU 38 Report, is often criticised as it is seldom representative of the highest bladder dose nor it gives an idea of the area exposed to a significant dose. Since November 1990, ultrasound measurements are routinely made in order to determine the actual dose delivered to the bladder of each patient. The technique was as follows. (1) the bladder is filled up with 150-200 cm3 of sterile isotonic saline. (2) The intrauterine position of the tube is checked. (3) The bladder anatomy is controlled. (4) Points of measurements are identified: ICRU bladder reference, minimum distance between bladder mucosa, uterine tube and other similar measurements taken every 15 mm along the radio-active line. Maximum and mean doses are calculated at the sagittal plane. Measurements are performed by moving the transducer along the skin of the patient and included in the calculation of dose distribution. Doses delivered to each relevant point are compared. This enables determination to be made of the differences between the ICRU and the doses actually observed at the bladder wall with aid of ultrasonography. BT applications were checked in 58 patients (69 measurements). The method was feasible in all cases. The comparison between ICRU dose from orthogonal films and the ICRU dose from ultrasonography resulted in a 90% accuracy. The maximum and mean doses for utero-vaginal BT are higher than the ICRU dose in 75% of cases (range, 2-8). Measurements are now abandoned for vaginal applications as the ICRU dose only could be measured.(ABSTRACT TRUNCATED AT 250 WORDS)
Authors:
I Barillot; J C Horiot; P Maingon; M C Bone-Lepinoy; D Vaillant; S Feutray
Related Documents :
20071767 - Stereotactic fields shaped with a micro-multileaf collimator: systematic characterizati...
19349657 - Comparison of pdr brachytherapy and external beam radiation therapy in the case of brea...
19928107 - Dose-calculation algorithms in the context of inhomogeneity corrections for high energy...
8873037 - Effects of irradiation geometry on treatment plan optimization with linac-based radiosu...
3276257 - Dosage and time effects of inhaled budesonide on bronchial hyperreactivity.
2788097 - Pharmacology of electrically evoked dopamine release studied in the rat olfactory tuber...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology     Volume:  30     ISSN:  0167-8140     ISO Abbreviation:  Radiother Oncol     Publication Date:  1994 Mar 
Date Detail:
Created Date:  1994-07-14     Completed Date:  1994-07-14     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8407192     Medline TA:  Radiother Oncol     Country:  IRELAND    
Other Details:
Languages:  eng     Pagination:  231-8     Citation Subset:  IM    
Affiliation:
Service de Radiothérapie, Centre de lutte contre le cancer Georges-François Leclerc, Dijon, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Balloon Dilatation
Brachytherapy* / instrumentation
Carcinoma / radiotherapy*
Endometrial Neoplasms / radiotherapy*
Female
Humans
Radiotherapy Dosage
Reference Values
Urinary Bladder / radiation effects*,  ultrasonography*
Urinary Catheterization
Uterine Cervical Neoplasms / radiotherapy*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A re-analysis of available dose-response and time-dose data in Hodgkin's disease.
Next Document:  Quality assurance in fractionated stereotactic radiotherapy.