Document Detail


Maximizing oxygen delivery during mechanical ventilation with a portable oxygen concentrator.
MedLine Citation:
PMID:  20622626     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Transportation of the critically ill or injured war fighter requires the coordinated care and judicious use of resources. Availability of oxygen (O2) supplies for the mechanically ventilated patient is crucial. Size and weight of cylinders makes transport difficult and presents an increased risk of fire. A proposed solution is to use a portable oxygen concentrator (POC) for mechanical ventilation. We tested the SeQual Eclipse II POC paired with the Impact 754 and Pulmonetics LTV-1200 ventilators in the laboratory and evaluated the fraction of inspired oxygen (FIO2) across a range of minute volumes. METHODS: Each ventilator was attached to a test lung and pressure, volume, flow, and inspired oxygen (FIO2) was measured by a gas or flow analyzer. Ventilators were tested at a tidal volume (VT) of 500 mL; an inspiratory time of 1.0 second; respiratory rates of 10, 20, and 30 breaths per minute; and positive end-expiratory pressure of 0 and 10 cm H2O. The LTV 1200 was tested with and without the expiratory bias flow. The Eclipse II was modified to provide pulse dosing on inspiration at 3 volumes (64, 128, and 192 mL) and continuous flow at 1 L/min to 3 L/min. Six combinations of ventilator settings were used with each POC setting for evaluation. O2 was injected at the ventilator gas outlet and patient y-piece for pulse dose and continuous flow. Additionally, continuous flow O2 was injected into the oxygen inlet port of the LTV 1200, and a reservoir bag, on the inlet port of the Impact 754. All tests were done with both ventilators using continuous flow, wall source O2 as a control. We also measured the FIO2 with the concentrator on the highest pulse dose setting while decreasing ventilator VT to compensate for the added volume. RESULTS: The delivered FIO2 was highest when oxygen was injected into the ventilator circuit at the patient y-piece using pulse dosing, with the VT corrected. The next highest FIO2 was with continuous flow at the inlet (LTV), and reservoir (Impact). Electrical power consumption was less during pulse dose operation. SUMMARY: Oxygen is a finite resource, which is cumbersome to transport and may present a fire hazard. The relatively high FIO2 delivered by the POC makes this method of O2 delivery a viable alternative to O2 cylinders. However, patients requiring an FIO2 of 1.0 would require additional compressed oxygen. This system allows O2 delivery up to 76% solely using electricity. An integrated ventilator or POC capable of automatically compensating VT for POC output is desirable. Further patient testing needs to be done to validate these laboratory findings.
Authors:
Dario Rodriquez; Thomas C Blakeman; Warren Dorlac; Jay A Johannigman; Richard D Branson
Related Documents :
2556046 - Adrenal blood flow and secretory relationships during hypoxia in anesthetized dogs.
15614126 - Effects of dopamine and norepinephrine on systemic and hepatosplanchnic hemodynamics, o...
17023676 - Hydrogen peroxide: a feed-forward dilator that couples myocardial metabolism to coronar...
7777706 - Hemoglobin function in a skin-breathing aquatic salamander, desmognathus quadramaculatus.
10941636 - Vasoconstrictive eicosanoid responses to extracorporeal circulation with or without an ...
8032646 - Effects of naftidrofuryl oxalate on microsphere embolism-induced decrease in regional b...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  The Journal of trauma     Volume:  69 Suppl 1     ISSN:  1529-8809     ISO Abbreviation:  J Trauma     Publication Date:  2010 Jul 
Date Detail:
Created Date:  2010-07-12     Completed Date:  2010-09-28     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0376373     Medline TA:  J Trauma     Country:  United States    
Other Details:
Languages:  eng     Pagination:  S87-93     Citation Subset:  AIM; IM    
Affiliation:
Center for Sustainment of Trauma and Readiness Skills (C-STARS), US Air Force, Cincinnati, Ohio, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Breath Tests
Critical Illness / therapy*
Equipment Design
Humans
Oxygen / administration & dosage,  analysis*
Oxygen Inhalation Therapy / instrumentation*
Respiration, Artificial / methods*,  standards
Transportation of Patients*
Ventilators, Mechanical / standards*
Chemical
Reg. No./Substance:
7782-44-7/Oxygen

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Predictors of early acute lung injury at a combat support hospital: a prospective observational stud...
Next Document:  Response to infection control challenges in the deployed setting: Operations Iraqi and Enduring Free...