Document Detail


Maxillary Sinus Augmentation without Grafting Material with Simultaneous Implant Installation: A Three-Dimensional Finite Element Analysis.
MedLine Citation:
PMID:  24995553     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE: The study aims to provide a theoretical guidance of postmaxillary implant in the augmented sinus without grafting materials by establishing a three-dimensional model of this new implant restorative technique, evaluating failure risk of sinus augmentation without grafting materials of different alveolar ridge heights, and analyzing stress distribution of different healing stage.
MATERIALS AND METHODS: Seventeen three-dimensional finite element models of a posterior maxillary region with sinus mucosa and different elevation heights were constructed according to anatomical data of sinus area, and the standard implant model based on Nobel Biocare implant system were created via computer-aided design software. All materials were assumed to be isotropic and linearly elastic. Axial force of 150 N was applied. The von Mises stress, stress distribution, and implant displacement were calculated with software.
RESULTS: With the height of the alveolar ridge reducing, the maximum von Mises stress of tissues and the displacement of the implant are on the rise, especially when the height of the bone is less than 7 mm. When the height decreased to 4 mm, the data may be doubled. After the stiff callus stage, the stress and displacement were close to the control model.
CONCLUSION: For maxillary sinus augmentation without grafting material implant technique, the stress of different tissues and the displacement of the implant were not increased much when the height of alveolar ridge is more than 7 mm. But if the alveolar bone height is less than 4 mm, this implant technique is not suggested. Immediately loading is not suggested and the loading opportunity should be after the stiff callus stage at least to improve the success rate.
Authors:
Xu Yan; Xinwen Zhang; Jie Gao; Yasuyuki Matsushita; Kiyoshi Koyano; Xi Jiang; Hongjun Ai
Related Documents :
23021113 - Tissue response during self-ligating treatment.
16796293 - Three-dimensional accuracy of implant placement in a computer-assisted navigation system.
1854443 - Microleakage of three resin placement techniques.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2014-7-3
Journal Detail:
Title:  Clinical implant dentistry and related research     Volume:  -     ISSN:  1708-8208     ISO Abbreviation:  Clin Implant Dent Relat Res     Publication Date:  2014 Jul 
Date Detail:
Created Date:  2014-7-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100888977     Medline TA:  Clin Implant Dent Relat Res     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
© 2014 Wiley Periodicals, Inc.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Alitretinoin (9-cis retinoic acid) is Effective Against Pityriasis Rubra Pilaris: A Retrospective Cl...
Next Document:  Facilitators of an Interprofessional Approach to Care in Medical and Mixed Medical/Surgical ICUs: A ...