Management of intra-aortic balloon pump entrapment: a case report and review of the literature.
MedLine Citation:
PMID:  23109753     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
An intra-aortic balloon pump is one of the most valuable tools in the cardiac surgeon's armament to assist in the management of the failing heart. Despite its widespread use, there are associated risks and complications, one of which is balloon rupture with associated entrapment. Numerous approaches for dealing with this complication have been described; here we review the previous experience with intra-aortic balloon pump entrapment and discuss potential management, with particular reference to a recent case of our own.
Authors:
Gerard J Fitzmaurice; Anton Collins; Haralambos Parissis
Related Documents :
17543753 - Incidental finding of cor triatriatum in an asymptomatic elite athlete.
9568223 - Premature "closing" of the foramen ovale in transposition of the great arteries with in...
22864723 - Pyloric atresia associated with epidermolysis bullosa: report of two cases and review o...
Publication Detail:
Type:  Case Reports; Journal Article; Review    
Journal Detail:
Title:  Texas Heart Institute journal / from the Texas Heart Institute of St. Luke's Episcopal Hospital, Texas Children's Hospital     Volume:  39     ISSN:  1526-6702     ISO Abbreviation:  Tex Heart Inst J     Publication Date:  2012  
Date Detail:
Created Date:  2012-10-30     Completed Date:  2013-04-10     Revised Date:  2013-07-11    
Medline Journal Info:
Nlm Unique ID:  8214622     Medline TA:  Tex Heart Inst J     Country:  United States    
Other Details:
Languages:  eng     Pagination:  621-6     Citation Subset:  IM    
Affiliation:
Department of Cardiac Surgery, The Royal Victoria Hospital, Belfast BT12 6BA, Northern Ireland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Coronary Artery Bypass / adverse effects*
Device Removal*
Equipment Design
Equipment Failure
Humans
Intra-Aortic Balloon Pumping / adverse effects,  instrumentation*
Male
Postoperative Complications / etiology,  radiography,  therapy*
Reoperation
Tomography, X-Ray Computed
Treatment Outcome
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Aortic valve noncoronary cusp thrombosis after implantation of a nonpulsatile, continuous-flow pump.
Next Document:  Left ventricular assist device implantation combined with surgical ventricular reconstruction.