Longitudinal resolution in volumetric x-ray computerized tomography--analytical comparison between conventional and helical computerized tomography.
MedLine Citation:
PMID:  8208218     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The primary advantage of helical computerized tomography (CT) is the capability of scanning a complete anatomical volume in a single breath hold. Due to the table motion and subsequent interpolation process, the slice sensitivity profile (SSP) in helical CT is worse than the response function of the detector array. In this paper, image longitudinal resolution in volumetric x-ray CT is analytically characterized, and a comparison made between conventional and helical CT. First, the SSPs are derived for both conventional and helical CT with the half-scan interpolation method under the condition that the table increment and detector collimation are the same. Then, the corresponding transfer functions are obtained for bandwidth determination, which directly describe the spatial resolution. Both one-tenth-cutoff and mean-square-root measures are used to quantify the bandwidth. Although it appears that broadening the SSP in helical CT could adversely affect longitudinal resolution, it is proved that for a given x-ray dose, helical CT allows substantially better longitudinal resolution than conventional CT due to its inherent retrospective reconstruction capability. To make full use of the potential of helical CT scan data, it is recommended that about five slices be reconstructed per table increment. Helical CT is superior in applications requiring a high longitudinal resolution.
Authors:
G Wang; M W Vannier
Related Documents :
11804898 - Suspected ureteral colic: primary helical ct versus selective helical ct after unenhanc...
10831718 - Reduced frequency of sedation of young children with multisection helical ct.
17641508 - Helical tomotherapy: image guidance and adaptive dose guidance.
12409578 - Ct in detecting urinary tract calculi: influence on patient imaging and clinical outcomes.
19083938 - Comparison of left ventricular size by computed tomography with magnetic resonance imag...
22475428 - Peptides and receptors in image-guided therapy: theranostics for neuroendocrine neoplasms.
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Medical physics     Volume:  21     ISSN:  0094-2405     ISO Abbreviation:  Med Phys     Publication Date:  1994 Mar 
Date Detail:
Created Date:  1994-07-08     Completed Date:  1994-07-08     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0425746     Medline TA:  Med Phys     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  429-33     Citation Subset:  IM    
Affiliation:
Division of Radiology Research, Mallinckrodt Institute of Radiology, Washington University Medical School, Saint Louis, Missouri 63110.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms*
Technology, Radiologic
Tomography, X-Ray Computed / methods*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of s...
Next Document:  Scatter compensation in digital chest radiography using the posterior beam stop technique.