Long term monitoring in patients receiving treatment to lower blood pressure: analysis of data from placebo controlled randomised controlled trial.
Jump to Full Text
MedLine Citation:
PMID:  19406886     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To determine the value of monitoring blood pressure by quantifying the probability that observed changes in blood pressure reflect true changes.
DESIGN: Analysis of blood pressure measurements of patients in the perindopril protection against recurrent stroke study (PROGRESS).
SETTING: Randomised placebo controlled trial carried out in 172 centres in Asia, Australasia, and Europe.
PARTICIPANTS: 1709 patients with history of stroke or transient ischaemic attack randomised to fixed doses of perindopril and indapamide. Measurements Mean of two blood pressure measurements in patients receiving treatment recorded to the nearest 2 mm Hg with a standard mercury sphygmomanometer at baseline and then at three months, six months, nine months, and 15 months and then every six months to 33 months.
RESULTS: There was no change in the mean blood pressure of the cohort during the 33 month follow-up. Six months after blood pressure was stabilised on treatment, if systolic blood pressure was measured as having increased by >10 mm Hg, six of those measurements would be false positives for every true increase of >or=10 mm Hg. The corresponding value for an increase of 20 mm Hg was over 200. Values for 5 mm Hg and 10 mm Hg increases in diastolic blood pressure were 3.5 and 39, respectively. The likelihood that observed increases in blood pressure reflected true increases rose with the time between measurements such that the ratio of true positives to false positives reached parity at 21 months.
CONCLUSIONS: Usual clinical approaches to the monitoring of patients taking drugs to lower blood pressure have a low probability of yielding reliable information about true changes in blood pressure. Evidence based guidelines for monitoring treatment response are urgently required to guide clinical practice. Trial registration Australia and New Zealand Clinical Trial Registry.
Authors:
Katherine Keenan; Andrew Hayen; Bruce C Neal; Les Irwig
Related Documents :
18656 - Changes in blood pressure and antihypertensive treatment in a community over four years.
20626346 - Why and how we should treat elderly patients with hypertension?
18386706 - Hemoglobin response and influence on left ventricular hypertrophy after 24-week treatme...
8613276 - Community-based education classes for hypertension control. a 1.5-year randomized contr...
20854616 - Feasibility of a pilot programme to increase awareness of blood pressure as an importan...
21247426 - Posterior leukoencephalopathy following repair of an ileocecal anastomosis breakdown: a...
Publication Detail:
Type:  Journal Article; Multicenter Study; Randomized Controlled Trial; Research Support, Non-U.S. Gov't     Date:  2009-04-30
Journal Detail:
Title:  BMJ (Clinical research ed.)     Volume:  338     ISSN:  1756-1833     ISO Abbreviation:  BMJ     Publication Date:  2009  
Date Detail:
Created Date:  2009-05-01     Completed Date:  2009-06-18     Revised Date:  2013-06-02    
Medline Journal Info:
Nlm Unique ID:  8900488     Medline TA:  BMJ     Country:  England    
Other Details:
Languages:  eng     Pagination:  b1492     Citation Subset:  AIM; IM    
Affiliation:
Screening and Test Evaluation Program (STEP), School of Public Health, Building A27, University of Sydney, New South Wales 2006, Australia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Antihypertensive Agents / therapeutic use*
Blood Pressure
Blood Pressure Determination
Diastole / physiology
Female
Humans
Hypertension / drug therapy*,  physiopathology
Indapamide / therapeutic use*
Ischemic Attack, Transient / physiopathology,  prevention & control*
Long-Term Care
Male
Middle Aged
Perindopril / therapeutic use*
Recurrence / prevention & control
Stroke / physiopathology,  prevention & control*
Treatment Failure
Chemical
Reg. No./Substance:
0/Antihypertensive Agents; 26807-65-8/Indapamide; 82834-16-0/Perindopril
Comments/Corrections
Comment In:
BMJ. 2009;338:b940   [PMID:  19454748 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): BMJ
Journal ID (publisher-id): bmj
ISSN: 0959-8138
ISSN: 1468-5833
Publisher: BMJ Publishing Group Ltd.
Article Information
Download PDF
? Keenan et al 2009
open-access: This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Accepted Day: 7 Month: 1 Year: 2009
collection publication date: Year: 2009
Print publication date: Year: 2009
Electronic publication date: Day: 30 Month: 4 Year: 2009
Volume: 338E-location ID: b1492
ID: 2675695
PubMed Id: 19406886
Publisher Id: keek583880
DOI: 10.1136/bmj.b1492

Long term monitoring in patients receiving treatment to lower blood pressure: analysis of data from placebo controlled randomised controlled trial
Katherine Keenan1 Role: general practitioner
Andrew Hayen1 Role: senior lecturer in biostatistics
Bruce C Neal2 Role: professor of medicine
Les Irwig1 Role: professor of epidemiology
1Screening and Test Evaluation Program (STEP), School of Public Health, Building A27, University of Sydney, New South Wales 2006, Australia
2George Institute for International Health, Royal Prince Alfred Hospital, Building C39, University of Sydney, New South Wales
Correspondence: Correspondence to: A Hayen ahayen@health.usyd.edu.au

Introduction

The size of the reduction in blood pressure achieved with antihypertensive drugs is key to the protection afforded by these agents.1 Clinicians commonly monitor the response of blood pressure to treatment2 to ensure maximum benefit for each individual. They typically monitor their patients? blood pressure shortly after initiation of treatment and then continue monitoring for the long term. Monitoring strategies are based on the assumption that measured blood pressure can be used to reliably identify the adequacy or inadequacy of treatment. Measurements of blood pressure, however, are rather imprecise because they are prone to considerable background day to day variability (?noise?) and this can make it difficult to detect a true change in blood pressure (?signal?). To be effective, long term monitoring requires the correct interpretation of measurements as reflecting either noise or signal. If the impact of noise is not fully appreciated then the effectiveness of treatments might be wrongly interpreted, resulting in under or over-treatment.3, 4, 5, 6

Patients established on blood pressure lowering drugs are monitored long term in anticipation of an increase in blood pressure in subsequent years. Monitoring is used to detect a rise in blood pressure above a certain threshold level (typically 140/90 mm Hg) that acts as a signal warranting re-measurement or adjustment of treatment. While an average increase in population blood pressure over time is well established, there is probably substantial variability in the size of the increase between individuals. This variability is expected to increase over time and, therefore, longer time intervals between measurements might increase the effectiveness of monitoring.

Patients on fixed doses of antihypertensive drugs, such as those in the treatment arms of randomised trials, provide an opportunity to examine to what extent the observed variability in blood pressure measurements in treated patients is caused by true changes in blood pressure. We studied the treatment arm of the perindopril protection against recurrent stroke study (PROGRESS) to examine how variability in blood pressure changes over time and its possible impact on monitoring strategies. We estimated the proportion of patients who would be correctly identified as having truly exceeded blood pressure thresholds for monitoring intervals of three to 33 months.


Methods

Details of the PROGRESS trial have been described previously.7 We analysed the dual treatment arm, for which active treatment was a regimen of perindopril 4 mg and indapamide 2.0-2.5 mg daily, using data from the visit at three months after randomisation until the three year visit. We restricted analyses to the active treatment arm because our objective was to assess long term variability after starting blood pressure lowering treatment. At each visit, recorded blood pressure was the mean of two measurements taken five minutes apart with the patient in the seated position, with each measurement being recorded to the nearest 2 mm Hg with a standard mercury sphygmomanometer. For the purpose of this analysis, the three month visit after randomisation was fixed as the time at which a patient will have achieved a reduction in blood pressure as a result of antihypertensive treatment and the time at which long term monitoring is initiated. We estimated long term change in blood pressure from this baseline measurement from the difference between it and the subsequent follow-up ?observed? blood pressure measurements at each time point (three months, six months, nine months, etc).

The observed blood pressure at each follow-up point comprises an underlying ?true? average blood pressure plus the ?short term variability? caused by technical measurement error and short term biological fluctuations (often called ?within person? variability or simply ?measurement error?). We use the term short term variability to describe fluctuations in blood pressure over a short time period (such as a few days or a week5). Short term variance is the statistical measure of short term variability. Squaring the standard deviation (SD) gives the ?variance,? which is an additive measure convenient for calculating changes in variability. Short term variability is part of each follow-up measurement?that is,

  • [observed follow-up blood pressure] = [true blood pressure] + [short term variability].

The short term variance can be estimated by halving the observed variance of the difference between two measurements made within a short time interval. As a first approximation, we obtained the short term variance from the difference between the measurements at six and three months. Because the three month time delay might incorporate some true long term change, however, we ultimately estimated the expected short term variance using the variogram approach8 (see appendix 1 on bmj.com).

Observed long term changes in blood pressure will incorporate the ?true? average change in the blood pressure, twice the short term variability (once for the initial measurement and once for the subsequent measurement), and the ?long term variability??that is,

  • [observed change in blood pressure from baseline] = [true average change in blood pressure] + 2 ? (short term variability) + (long term variability)].

The long term variability is the ?between person? variability caused by individuals? long term changes in blood pressure deviating above or below the average change of the group. The long term variance can be estimated from the total observed variance of the difference in blood pressure measurements from the baseline to each subsequent time point. The above equation shows that subtracting twice the short term variance from the total observed variance of the change will give an estimate of the long term variance (see appendix 1 on bmj.com).

Using the calculated change in variance at each time point, we estimated the proportion of patients whose assumed true baseline systolic blood pressure of 130 or 120 mm Hg would truly increase by 10 or 20 mm Hg (called true positives) to a threshold of 140 mm Hg or above while receiving treatment. We also estimated the proportion of patients who would be observed to be above the thresholds but who actually had true blood pressure levels below the threshold (that is, false positives). We repeated this for an assumed true baseline diastolic blood pressure of 85 or 80 mm Hg and used changes in blood pressure of 5 or 10 mm Hg to reach a threshold of 90 mm Hg or above. For both systolic and diastolic blood pressure we estimated these assuming no change in mean blood pressure over the three year period. In sensitivity analyses we also estimated the true and false positive probabilities assuming an average 1.0 mm Hg per year increase in systolic blood pressure and a 0.5 mm Hg per year increase in diastolic blood pressure.9 The calculations assume that the baseline value and the true change with time are normally distributed and are independent of each other. See appendix 1 on bmj.com for full details of the methods.

Previous research has shown distributions of systolic blood pressure to be skewed to the right and variability to be correlated with blood pressure levels.5, 10, 11, 12, 13 Therefore, we checked the distributions of systolic and diastolic blood pressure for normality and examined Bland-Altman plots of the difference in the measurements from baseline to three months against the average of these two measurements. Use of a natural log transformation normalised distributions of systolic blood pressure and reduced the correlation between variability and blood pressure level, and we subsequently repeated analyses after natural log transformation of systolic blood pressure measurements.

Because the methods described above assume independence between baseline blood pressure and the true change from baseline blood pressure, we also repeated the analyses using an approach based on mixed models, which do not assume independence between baseline level and the true change from baseline level.


Results
Baseline characteristics

Detailed characteristics of the participants at enrolment have been described previously,14 but table 1 summarises demographic and blood pressure characteristics relevant to this studytbl1. About 38% (n=1357) of patients at randomisation were recruited in Asian countries (China or Japan) and the remainder in Australasia and Europe. At three months after randomisation, blood pressure measurements were available for 1709 study participants receiving dual active treatment. At 33 months of follow-up, more than 93% (1591) of these individuals had blood pressure measurements recorded.

At baseline visit (three months after randomisation to active combination treatment with an angiotensin converting enzyme (ACE) inhibitor and a diuretic) participants had an average systolic blood pressure of 133 (SD 17) mm Hg and diastolic blood pressure of 80 (SD 10) mm Hg. Blood pressure had decreased on average 16 mm Hg and 7 mm Hg, respectively, from that recorded before treatment started. Over half (58%) of participants were prescribed an additional antihypertensive drug (in addition to perindopril and indapamide) at randomisation and 38% at three years? follow-up.

Follow-up blood pressure and variability

Systolic blood pressure?The mean blood pressure in the 1709 participants did not change substantially during follow-up (table 2)tbl2. The variability of the difference from baseline increased over time, as shown by the increasing variance (table 2) and the distribution centiles (fig 1)fig1. The short term variance was estimated to be 93.3 mm Hg2 (that is, SD 9.7 mm Hg). Long term variability increased over the 30 month interval from an SD of 3.8 mm Hg at three months to 11.8 mm Hg at 33 months. Appendix 2 on bmj.com shows comparable results for analyses based on the logarithm of systolic blood pressure.

Diastolic blood pressure?The mean blood pressure did not change over time (table 3)tbl3. As for systolic blood pressure, however, the variability of difference in diastolic blood pressure from baseline increased with the duration of follow-up (table 3 and fig 2)fig2. The short term variance was estimated to be 33.2 mm Hg2 (that is, SD 5.8 mm Hg). Long term variability increased over the 30 months from an SD of 2.7 mm Hg at three months to 6.6 mm Hg at 33 months.

Probability of observed increases in blood pressure reflecting true treatment failures

Tables 4tbl4 and 5tbl5 show the probabilities that a threshold systolic of 140 mm Hg or diastolic of 90 mm Hg in a treated patient actually represents a true failure of treatment. Findings are shown for monitoring intervals of between three and 33 months after the start of treatment.

We estimated the probabilities in table 4 using the natural log of measurements of systolic blood pressure to normalise the data, assuming no change in the underlying mean blood pressure of the group and a true blood pressure of either 120 or 130 mm Hg at baseline.tbl4 As such they are the probabilities that an observed increase of 10 or 20 mm Hg from a true baseline systolic blood pressure is in fact a true increase of 10 or 20 mm Hg. For example, suppose that an increase of 20 mm Hg in the systolic blood pressure is considered as a ?signal? for altering treatment. A patient with a baseline measurement of 120 mm Hg monitored at six months has a 0.02% probability of the measurement truly reaching 140 mm Hg or above. However, 3.4% of individuals would record blood pressure levels of 140 mm Hg or above at six months, meaning that for every one true positive result (that is, a true increase of 20 mm Hg) there would be more than 200 other individuals who had an apparent 20 mm Hg increase in systolic blood pressure that was caused solely by measurement error.

Likewise, we estimated the probabilities in table 5 assuming no change in the underlying mean diastolic blood pressure of the group and a true blood pressure of either 85 or 90 mm Hg at baseline.tbl5 They represent the probability of an observed increase being a true increase of 5 or 10 mm Hg from the true baseline measurement. Again, by way of example, suppose that an increase of 10 mm Hg is considered a ?signal? for altering treatment in a patient with a true baseline measurement of 80 mm Hg. If the patient is monitored at six months there is a 0.3% probability of the measurement truly reaching 90 mm Hg or over. Measurements taken at this time interval would yield an observed positive result in 7.2% of individuals, meaning that for every one true positive result (that is, a true increase of 10 mm Hg) there would be 39 individuals falsely interpreted as having a 10 mm Hg increase in diastolic blood pressure.

The findings in tables 4 and 5 were not substantively different in sensitivity analyses in which we incorporated small annual rises in average population blood pressure (1.0 mm Hg per year for systolic and 0.5 mm Hg per year for diastolic).tbl4tbl5 Likewise, in analyses based on mixed models we found no substantial differences in interpretation of the resultant true positive/false positive tables (tables 4 and 5).


Discussion

It is usual practice for patients on blood pressure lowering drugs to have their prescription renewed or drugs altered on the basis of blood pressure measurements and clinical review every six months or so.15, 16, 17 Our results provide little evidence to support the modification of blood pressure management on the basis of measurements made at this interval. If the true on treatment diastolic blood pressure was initially 80 mm Hg then 5.8% of patients would be observed three months later to have a ?10 mm Hg increase to 90 mm Hg or over. This would reflect more than 1000 false positives for every true increase, and in nearly all patients in whom treatment was identified as failing the apparently high blood pressure levels would reflect only measurement error. If the true on treatment diastolic blood pressure was 85 mm Hg instead then 21.6% of patients would be observed to have a ?5 mm Hg increase to 90 mm Hg or over. A much greater proportion of these observations would reflect real increases in blood pressure but there would still be about 11 false positives for every true increase.

It is clear from these data that a single careful blood pressure measurement taken a few months after the start of treatment is not useful for monitoring. The progressive increase over time in the long term variability of measurements between individuals means that an observed change in blood pressure was more likely to reflect a true change in blood pressure with an increase in the time between the start of treatment and follow-up monitoring. This effect was largely driven by the number of true positives increasing with the time interval, while the number of false positives remained fairly constant. The probability that an apparent increase in blood pressure was a true increase rather than a false positive, however, was still not much better than 50% if the first monitoring interval was left until nearly two years after the start of monitoring.

These data suggest that having accurate measurements of blood pressure at intervals longer than every six months is probably more useful for monitoring patients receiving antihypertensive drugs than the current practice of a clinic measurement every six months. There are several possible strategies for improving the effectiveness of monitoring that need careful quantitative assessment. The chance of detecting true increases in blood pressure would be increased if an abnormal measurement was used as a signal for making a series of repeat measurements at short time intervals. Likewise, having a more accurate estimate of blood pressure at baseline and follow-up would minimise short term variability and increase the capacity to separate true changes from background noise. These more accurate estimates can be achieved by using calibrated sphygmomanometers, taking measurements at set times in relation to drug treatment, and taking the mean of several measurements, perhaps with self monitoring.18 Alternatively, control charts,19 which facilitate the separation of apparently abnormal measurements from background variability by plotting re-measurements made at shortened time intervals, can achieve a better interpretation of the true blood pressure for any one individual.8

Limitations and strengths

There were several potential limitations to this study. Firstly, over half of the patients involved were using blood pressure lowering drugs in addition to the perindopril-indapamide studied here; this might have increased the variability in blood pressure in this population. Secondly, participants had all had a previous stroke or a transient ischaemic attack, which might be associated with a higher variability of blood pressure than in the general population.15 That said, the estimated coefficient of variation in diastolic blood pressure in this study (7.2%) is less than has been found in clinical practice (11.4% to 16.6%),3 and blood pressure measurements in a clinical trial such as PROGRESS are probably less variable than in clinical practice and less prone to other problems such as zero digit bias.20 If there were for any reason extra long term variability in these patients compared with the general population, then our estimates of the effectiveness of monitoring would probably be overestimated. Likewise, we would expect additional long term variability to have resulted from participants in this cohort discontinuing double blind treatment, which would also imply that we have overestimated rather than underestimated the effectiveness of monitoring.

Given the lack of clear quantitative data about the effectiveness of different blood pressure monitoring strategies it is perhaps unsurprising that current hypertension guidelines pay little attention to monitoring of patients after the start of treatment.16, 17, 21, 22 While the absence of evidence precludes the recommendation of specific follow-up regimens, guidelines could help clinicians to better interpret the meaning of observed increases in blood pressure. For example, if clinicians and patients can be provided with information about the probability that an observed rise is a true rise it would help them to make better decisions about management and avoid a cycle of unnecessary adjustments to treatment and undesirable fluctuations in blood pressure. Such a ?ping pong? effect has been observed with the adjustment of warfarin treatment in response to the international normalised ratio (INR)4, 23 and might be a problem for many people taking blood pressure lowering drugs.

Follow-up visits and blood pressure monitoring are also used to assess and enhance adherence to treatment. Clearly the observed follow-up blood pressure is going to be a poor indicator of adherence for the same reason that it is a poor indicator of response to treatment, and monitoring prescription records or sensitively questioning patients will probably provide a better assessment of adherence.24

Conclusion

We have shown that the probability of correctly identifying true increases in blood pressure of moderate magnitude using a typical monitoring regimen is poor, with a large proportion of observed increases in blood pressure being false positives. Monitoring at shorter time intervals increases the probability of identifying false positive increases in blood pressure attributable to short term within person variability of blood pressure. Longer intervals between measurements increase the probability that an observed increase in blood pressure is real, but the capacity of monitoring to distinguish true increases in blood pressure is poor even if monitoring is left for several years. Clinicians need better information about the value of different monitoring strategies, and future evidence based monitoring guidelines would be invaluable.

What is already known on this topic
  • Long term monitoring of patients receiving blood pressure lowering drugs is common clinical practice and recommended by guidelines
  • Individuals? blood pressures vary considerably from day to day, making it difficult to measure the true level
  • Assessments of treatment efficacy based on noisy measurements might be misleading
What this study adds
  • Recommended monitoring strategies are poor methods for detecting response to blood pressure lowering drug treatment
  • Guidelines for the management of blood pressure should include evidence based recommendations about monitoring strategies in addition to providing advice about the choice of treatment

Notes

Contributors: LI conceived the study and is guarantor. All authors contributed to the ideas and writing.

Funding: This study was funded by the Australian National Health and Medical Research Council Program, grants 402764 and 358395. All of the researchers involved in this project are independent of the funding body (Australian National Health and Medical Research Council).

PROGRESS was funded by grants from Servier, the Health Research Council of New Zealand, and the National Health and Medical Research Council of Australia. The study was designed, conducted, analysed, and interpreted by the investigators independently of all sponsors.

Competing interests: BN has received honoraria from Servier for speaking at scientific meetings. Servier provide research support for the ADVANCE trial of which BN is a management committee member.

Ethical approval: Not required.

Notes

Contributors: LI conceived the study and is guarantor. All authors contributed to the ideas and writing.

Funding: This study was funded by the Australian National Health and Medical Research Council Program, grants 402764 and 358395. All of the researchers involved in this project are independent of the funding body (Australian National Health and Medical Research Council).

PROGRESS was funded by grants from Servier, the Health Research Council of New Zealand, and the National Health and Medical Research Council of Australia. The study was designed, conducted, analysed, and interpreted by the investigators independently of all sponsors.

Competing interests: BN has received honoraria from Servier for speaking at scientific meetings. Servier provide research support for the ADVANCE trial of which BN is a management committee member.

Ethical approval: Not required.


References
1. Blood Pressure Lowering Treatment Trialists? Collaboration. Effects of different blood-pressure-lowering regimens on major cardiovascular events: results of prospectively-designed overviews of randomised trials. Lancet 2003; 362:1527-35. [pmid: 14615107]
2. Britt H, Miller G, Charles J, Pan Y, Valenti L, Henderson J, et al. General practice activity in Australia 2005-06 Canberra: Australian Institute of Health and Welfare, 2007
3. Marshall T. Measuring blood pressure: the importance of understanding variation. Brasilian J Hypertens 2005; 12:75-82.
4. Glasziou P. How should we adjust treatment? In: Glasziou P, Aronson J, Irwig L, eds. Evidence-based medical monitoring: from principles to practice Malden: Blackwell Publishing, 2008
5. Rosner B, Polk BF. The implications of blood pressure variability for clinical and screening purposes. J Chronic Dis 1979; 32:451-61. [pmid: 457829]
6. Glasziou P, Irwig L, Mant D. Monitoring in chronic disease: a rational approach. BMJ 2005; 330:644-8. [pmid: 15774996]
7. PROGRESS Collaborative group. Randomised trial of a perindopril-based blood-pressure-lowering regimen among 6105 individuals with previous stroke or transient ischaemic attack. Lancet 2001; 358:1033-41. [pmid: 11589932]
8. Shepard D. Reliability of blood pressure measurements: implications for designing and evaluating programs to control hypertension. J Chronic Dis 1981; 34:191-209. [pmid: 7240360]
9. Landahl S, Bengtsson C, Sigurdsson JA, Svanborg A, Svardsudd K. Age-related changes in blood pressure. Hypertension 1986; 8:1044-9. [pmid: 3770866]
10. Goldberg AD, Raftery EB, Cashman PM, Stott FD, Goldberg AD, Raftery EB, et al. Study of untreated hypertensive subjects by means of continuous intra-arterial blood pressure recordings. Br Heart J 1978; 40:656-64. [pmid: 656239]
11. Watson RD, Stallard TJ, Flinn RM, Littler WA. Factors determining direct arterial pressure and its variability in hypertensive man. Hypertension 1980; 2:333-41. [pmid: 6993360]
12. Mancia G, Ferrari A, Gregorini L, Parai G, Pomidossi G, Bertinieri G, et al. Blood pressure and heart rate variabilities in normotensive and hypertensive human beings. Circ Res 1983; 53:96-104. [pmid: 6861300]
13. Gordon T, Sorlie P, Kannel WB. Problems in the assessment of blood pressure: the Framingham study. Int J Epidemiol 1976; 5:327-34. [pmid: 1010660]
14. Progress Management Committee. PROGRESS?perindopril protection against recurrent stroke study characteristics of the study population at baseline. J Hypertenson 1999; 17:1647-55.
15. Howard SC, Rothwell PM. Regression dilution of systolic and diastolic blood pressure in patients with established cerebrovascular disease. J Clin Epidemiol 2003; 56:1084-91. [pmid: 14614999]
16. Mancia G, De Backer G, Dominiczak A, Cifkova R, Fagard R, Germano G, et al. 2007 Guidelines for the management of arterial hypertension: the task force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). J Hypertens 2007; 25:1105-87. [pmid: 17563527]
17. National Heart Foundation of Australia. Hypertension management guide for doctors 2004 Melbourne: National Heart Foundation, 2003
18. McManus RJ, Glasziou P, Hayen A, Mant J, Padfield P, Potter J, et al. Blood pressure self monitoring: questions and answers from a national conference. BMJ 2008:a2732.
19. Macaskill P. Control charts and control limits in long-term monitoring. In: Glasziou P, Irwig L, Aronson J, eds. Evidence-based medical monitoring. From principles to practice Malden: Blackwell Publishing Inc, 2008
20. Harrison WN, Lancashire RJ, Marshall TP. Variation in recorded blood pressure terminal digit bias in general practice. J Hum Hypertens 2008; 22:163-7. [pmid: 18046433]
21. Whitworth JA, World Health Organization International Society of Hypertension Writing Group. 2003 World Health Organization (WHO)/International Society of Hypertension (ISH) statement on management of hypertension. J Hypertens 2003; 21:1983-92. [pmid: 14597836]
22. Williams B, Poulter N, Brown M, Davis M, McInnes G, Potter J, et al. Guidelines for the management of hypertension: report of the fourth working party of the British Hypertension Society, 2004-BHS IV. J Hum Hypertens 2004; 18:139-85. [pmid: 14973512]
23. Lassen JF, Kjeldsen J, Antonsen S, Hyltoft Petersen P, Brandslund I. Interpretation of serial measurements of international normalized ratio for prothrombin times in monitoring oral anticoagulant therapy. Clin Chem 1995; 41:1171-6. [pmid: 7628093]
24. MacLaughlin EJ, Raehl CL, Treadway AK, Sterling TL, Zoller DP, Bond CA. Assessing medication adherence in the elderly: which tools to use in clinical practice? Drugs Aging 2005; 22:231-55. [pmid: 15813656]

Notes

Cite this as: BMJ 2009;338:b1492


Figures

[Figure ID: fig1]

Fig 1 Difference in systolic blood pressure (mm Hg) from baseline measurement to subsequent measurements over time to 33 months in those receiving dual treatment



[Figure ID: fig2]

Fig 2 Difference in diastolic blood pressure (mm Hg) from baseline measurement to subsequent measurements over time to 33 months in those receiving dual treatment



Tables
[TableWrap ID: tbl1] Table 1 

?Characteristics of participants randomised to dual treatment for hypertension


After start of treatment (baseline) (n=1709) Before start of treatment (n=1770)
Mean (SD) age (years) 63 (9) 63 (9)
No (%) of men 1205 (71) 1243 (70)
Mean (SD) blood pressure (mm Hg):
?Systolic 133 (17) 149 (18)
?Diastolic 80 (10) 87 (11)
No (%) with hypertension* 341 (20) 948 (54)
No (%) taking other antihypertensive drug? 678 (41)? 1009 (57)

*Systolic blood pressure ?160 mm Hg or diastolic blood pressure ?90 mm Hg.

?Taking blood pressure lowering drug other than trial drug.

?On other antihypertensive drugs nine months after start of monitoring. Denominator=1668 patients. Data not available at start of monitoring.


[TableWrap ID: tbl2] Table 2 

?Long term variability of systolic blood pressure for those receiving dual treatment, calculated from difference from on treatment baseline measurement of 133 mm Hg (SD 17) to each subsequent time point


Time (months) No of patients Difference from baseline (mm Hg) Long term variance* (mm Hg2) Long term SD? (mm Hg)
Mean (95% CI) Variance
3 1670 0.7 (0.01 to 1.37) 200.9 14.4 3.8
6 1638 ?0.3 (?1.0 to ?0.5) 224.1 37.6 6.1
9 1644 ?0.9 (?1.7 to ?0.08) 270.8 84.3 9.2
15 1624 ?0.4 (?1.2 to 0.4) 283.6 97.0 9.8
21 1612 ?0.7 (?1.6 to 0.1) 303.6 117.1 10.8
27 1585 ?0.2 (?1.0 to 0.7) 313.3 126.7 11.3
33 1560 ?1.3 (?2.2 to ?0.4) 325.8 139.3 11.8

*Estimated by subtracting twice short term variance (93.3 mm Hg) from variance of difference.

?Square root of long term variance.


[TableWrap ID: tbl3] Table 3 

?Long term variability of diastolic blood pressure for those receiving dual treatment; calculated from difference from on treatment baseline measurement 80 mm Hg (SD 10) to each subsequent time point


Time (months) No of patients Difference from baseline (mm Hg) Long term variance* (mm Hg2) Long term SD? (mm Hg)
Mean (95% CI) Variance
3 1670 0.2 (?0.2 to 0.6) 73.6 7.2 2.7
6 1637 ?0.5 (?0.9 to ?0.04) 79.7 13.3 3.6
9 1644 ?0.9 (?1.3 to ?0.4) 90.9 24.5 4.9
15 1623 ?0.5 (?1.1 to ?0.1) 93.1 26.7 5.1
21 1612 ?1.0(?1.5 to ?0.5) 101.8 35.4 5.9
27 1584 ?1.0 (?1.5 to ?0.5) 108.3 41.9 6.5
33 1560 ?1.6 (?2.1 to ?1.0) 109.9 43.5 6.6

*Estimated by subtracting twice short term variance (33.2 mm Hg) from variance of difference.

?Square root of long term variance.


[TableWrap ID: tbl4] Table 4 

?Estimated number of true positive and false positive measurements of systolic blood pressure over threshold of 140 mm Hg from on treatment baseline ?true? measurement of 120 mm Hg or 130 mm Hg


True baseline measurement and time interval between on treatment baseline and follow-up measurements (months) % of all measurements truly ?140 mm Hg ?Observed? positive* test as % of all measurements (true positive+false positive) Ratio of false positive tests to true positive tests
120 mm Hg
3 0.0000008 2.3 (0.000008+2.3) >1 000 000
6 0.02 3.4 (0.01+3.4) >200
9 1.2 6.0 (0.7+5.3) 7.2
15 1.6 6.6 (1.0+5.5) 5.3
21 2.6 7.5 (1.7+5.8) 3.4
27 3.2 8.0 (2.1+6.0) 2.9
33 3.8 8.6 (2.5+6.1) 2.4
130 mm Hg
3 0.3 16.8 (0.2+16.6) 93
6 4.6 19.0 (2.7+16.3) 6.0
9 13.8 22.7 (9.3+13.5) 1.5
15 15.3 23.4 (10.4+13.0) 1.3
21 17.5 24.5 (12.2+12.2) 1.0
27 18.6 25.0 (13.1+11.9) 0.9
33 19.7 25.6 (14.1+11.5) 0.8

*?Positive? test is increase in blood pressure above threshold.


[TableWrap ID: tbl5] Table 5 

?Estimated number of true positive and false positive measurements of diastolic blood pressure over threshold of 90 mm Hg from baseline measurement of 80 or 85 mm Hg


True baseline measurement and time interval between on treatment baseline and follow-up measurements (months) % of all measurements truly ?90 mm Hg ?Observed? positive* test as % of all measurements (true positive+false positive) Ratio of false positive tests to true positive tests
80 mm Hg
3 0.01 5.8 (0.005+5.8) >1000
6 0.3 7.2 (0.2+7.0) 39
9 2.2 9.4 (1.3+8.1) 6.0
15 2.7 9.9 (1.7+8.2) 4.9
21 4.6 11.3 (3.0+8.3) 2.7
27 6.1 12.4 (4.1+8.3) 2.0
33 6.5 12.7 (4.4+8.3) 1.9
85 mm Hg
3 3.1 21.6 (1.8+19.8) 11
6 8.5 23.2 (5.2+18.0) 3.5
9 15.6 25.5 (10.3+15.2) 1.5
15 16.7 26.0 (11.2+14.8) 1.3
21 20.0 27.3 (13.9+13.4) 1.0
27 22.0 28.2 (15.6+12.6) 0.8
33 22.4 28.4 (16.0+12.4) 0.8

*?Positive? test is increase in blood pressure above threshold.



Article Categories:
  • Research
Article Categories:
  • Clinical Trials (Epidemiology)
  • Stroke
  • Hypertension


Previous Document:  Fetal cerebral blood flow, electrocorticographic activity, and oxygenation: responses to acute hypox...
Next Document:  Longitudinal community plasma HIV-1 RNA concentrations and incidence of HIV-1 among injecting drug u...