Document Detail


Loads applied tangential to a fingertip during an object restraint task can trigger short-latency as well as long-latency EMG responses in hand muscles.
MedLine Citation:
PMID:  12898103     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Electrical stimulation of the digital nerves can cause short- and long-latency increases in electromyographic activity (EMG) of the hand muscles, but mechanical stimulation of primarily tactile afferents in the digits generally evokes only a long-latency increase in EMG. To examine whether such stimuli can elicit short-latency reflex responses, we recorded EMG over the first dorsal interosseous muscle when subjects (n=13) used the tip of the right index finger to restrain a horizontally oriented plate from moving when very brisk tangential forces were applied in the distal direction. The plate was subjected to ramp-and-hold pulling loads at two intensities (a 1-N load applied at 32 N/s or a 2-N load applied at 64 N/s) at times unpredictable to the subjects (mean interval 2 s; trial duration 500 ms). The contact surface of the manipulandum was covered with rayon--a slippery material. For each load, EMG was averaged for 128 consecutive trials with reference to the ramp onset. In all subjects, an automatic increase in grip force was triggered by the loads applied at 32 N/s; the mean onset latency of the EMG response was 59.8 +/- 0.9 (mean +/- SE) ms. In seven subjects (54%) this long-latency response was preceded by a weak short-latency excitation at 34.6 +/- 2.9 ms. With the loads applied at 64 N/s, the long-latency response occurred slightly earlier (58.9 +/- 1.7 ms) and, with one exception, all subjects generated a short-latency EMG response (34.9 +/- 1.3 ms). Despite the higher background grip force that subjects adopted during the stronger loads (4.9 +/- 0.3 N vs 2.5 +/- 0.2 N), the incidence of slips was higher--the manipulandum escaped from the grasp in 37 +/- 5% of trials with the 64 N/s ramps, but in only 18 +/- 4% with the 32-N/s ramps. The deformation of the fingertip caused by the tangential load, rather than incipient or overt slips, triggered the short-latency responses because such responses occurred even when the finger pad was fixed to the manipulandum with double-sided adhesive tape so that no slips occurred.
Authors:
Vaughan G Macefield; Roland S Johansson
Related Documents :
7182603 - Changes in the fdp (fibrin and fibrinogen degradation products) value under mental and ...
18187473 - Postural control at the human wrist.
19045653 - Measuring distortion product otoacoustic emissions using continuously sweeping primaries.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2003-07-26
Journal Detail:
Title:  Experimental brain research     Volume:  152     ISSN:  0014-4819     ISO Abbreviation:  Exp Brain Res     Publication Date:  2003 Sep 
Date Detail:
Created Date:  2003-09-04     Completed Date:  2003-11-06     Revised Date:  2013-12-13    
Medline Journal Info:
Nlm Unique ID:  0043312     Medline TA:  Exp Brain Res     Country:  Germany    
Other Details:
Languages:  eng     Pagination:  143-9     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Electromyography
Female
Fingers / physiology*
Hand*
Humans
Male
Middle Aged
Muscle, Skeletal / physiology*
Reaction Time
Weight-Bearing / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Bursts in the medial geniculate body: a comparison between anesthetized and unanesthetized states in...
Next Document:  Anodic stripping voltammetric determination of mercury using multi-walled carbon nanotubes film coat...