| Limitations of the of the oscillometric method for blood pressure measurements in dialyzed patients. | |
| | |
MedLine Citation:
|
PMID: 21455115 Owner: NLM Status: In-Data-Review |
Abstract/OtherAbstract:
|
Background: Despite more frequent use of the oscillometric method (OSC) for arterial blood pressure (BP) measurement, little is known about OSC's accuracy when used with hemodialysed patients. This study was undertaken to determine if hemodialysis (HD) and individual features in examined patients can affect the accuracy of OSC for BP measurement.<br /> Material/Methods: In 54 hemodialysed patients (57±15 years), during 2 sessions (before and after HD), 3 pairs of BP measurements each were performed on arms, alternately employing OSC and auscultatory method, with mercury manometers by 2 observers (REF).<br /> Results: No difference was found in systolic BP measured before and after HD (SBP before HD: REF -147.3±27.3, OSC -147.5±25.0 mmHg, p>0.05, SBP after HD: REF-141.1±33.9, OSC-141.2±31.5 mmHg, p>0.05, respectively), but diastolic BP (DBP) was significantly higher both before and after HD during REF measurement in comparison with OSC (DBP before HD: REF -79.0±17.0, OSC -76.7±15.0 mmHg, DBP after HD: REF -78.6±18.8, OSC -76.7±16.7 mmHg, p<0.001, respectively). No significant correlation between loss of body weight caused by HD and differences in BP measured by REF and OSC after HD was indicated (Pearson's correlation coefficients: for SBP -0.041, for DBP 0.030). However, a significant correlation between differences in BP measured by REF and OSC before HD and differences in BP measured by REF and OSC after HD was observed (Spearman's rank correlation coefficients: for SBP 0.502 and for DBP 0.557, p<0.000001).<br /> Conclusions: Our study found that individual features, not HD, determine the accuracy of OSC for BP measurement in hemodialysed patients.<br /> |
| | |
Authors:
|
Marek Czarkowski; Monika Staszkow; Kacper Kostyra; Zuhier Shebani; Krzysztof Rozanowski; Joanna Matuszkiewicz-Rowinska; Stanislaw Niemczyk |
Related Documents
:
|
7111865 - Ventilatory response of humans to chronic contraceptive pill administration. 16933075 - An evaluation of acid-base changes following aortic cross-clamping using transcutaneous... 1903005 - Efficiency of bleeding of broilers after gaseous or electrical stunning. 8272995 - Alterations in respiratory function and hemodynamics during laparoscopic cholecystectom... 3877015 - The effect of several different anaesthetics on the blood pressure and heart rate of th... 7960015 - Chronic administration of aldosterone depresses baroreceptor reflex function in the dog. |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: Medical science monitor : international medical journal of experimental and clinical research Volume: 17 ISSN: 1643-3750 ISO Abbreviation: Med. Sci. Monit. Publication Date: 2011 Apr |
Date Detail:
|
Created Date: 2011-04-01 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 9609063 Medline TA: Med Sci Monit Country: Poland |
Other Details:
|
Languages: eng Pagination: MT35-40 Citation Subset: IM |
Affiliation:
|
Department of Internal Medicine and Endocrinology, Medical University of Warsaw, Warsaw, Poland. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: A possible prevention strategy of radiation pneumonitis: Combine radiotherapy with aerosol inhalatio...
Next Document: Effect of hormone replacement therapy (HRT) on periodontal status of postmenopausal women.