Document Detail

Late Positive Remodeling and Late Lumen Gain Contribute to Vascular Restoration by a Non-Drug Eluting Bioresorbable Scaffold: A Four-Year Intravascular Ultrasound Study in Normal Porcine Coronary Arteries.
MedLine Citation:
PMID:  22253358     Owner:  NLM     Status:  Publisher    
BACKGROUND: The interplay between mechanical dilatation, resorption, and arterial response following implantation of bioresorbable scaffolds is still poorly understood. METHODS AND RESULTS: Long-term geometric changes in porcine coronary arteries in relation to gradual degradation of bioresorbable scaffolds were assessed in comparison with bare metal stents (BMS). Intravascular ultrasound (IVUS)-derived lumen, outer stent/scaffold, and reference vessel areas were evaluated in 94 polymer scaffolds and 46 BMS at 5 days and 3, 6, 12, 18, 24, and 55 months, in addition to polymer scaffold radial crush strength and molecular weight (M(w)) at 3, 6, and 12 months. BMS outer stent area and lumen area remained constant through 55 months (P=0.05, but within 1 standard deviation of 100%, and P=0.58, respectively), while significant increases were exhibited by polymer-scaffolded vessels with the maximum late lumen gain at 24 months, paralleled by the outer scaffold area increase, and then remaining at that increased level at 55 months (P<0.01). By 12 months polymer scaffolds experienced significant reductions in radial strength and M(w), while the animals underwent the largest weight gain. At 3 months and beyond, the patency ratio (lumen area/reference vessel area) of BMS remained constant (0.71 to 0.85, P=0.49). In contrast, that of polymer scaffolds increased and approached 1 (P=0.13). CONCLUSIONS: Bioresorbable polymer scaffolds allow restoration of the treated segment's ability to remodel outward to achieve level lumen transition between reference vessel and scaffold-treated regions, a process mediated by animal growth and scaffold degradation. This also introduces a challenge to standard analyses of IVUS outcomes relying on constant stent diameters over time.
Erika Strandberg; Joan Zeltinger; Daryl G Schulz; Greg L Kaluza
Related Documents :
17559528 - The use of a diagnostic matrix in the management of the severely worn dentition.
3198778 - Improvement of oral hygiene habits: a psychological approach. 2-year data.
1745508 - Evaluation of 0.12% chlorhexidine rinse on the prevention of alveolar osteitis.
20452258 - The sealing ability of resilon and gutta-parcha following different smear layer removal...
11692058 - Twenty-four-hour ph monitoring is required to confirm acid reflux suppression in patien...
1441948 - Prognosis in perthes' disease after noncontainment treatment. 106 hips followed for 28-...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-1-17
Journal Detail:
Title:  Circulation. Cardiovascular interventions     Volume:  -     ISSN:  1941-7632     ISO Abbreviation:  -     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-1-18     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101499602     Medline TA:  Circ Cardiovasc Interv     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
REVA Medical, Inc, San Diego, CA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Composition of Target Lesions by Near-Infrared Spectroscopy in Patients With Acute Coronary Syndrome...
Next Document:  Bare Metal Stent Thrombosis and In-Stent Neoatherosclerosis.