Abstract/OtherAbstract:
BACKGROUND: A variety of permanent and absorbable tacks are available for mesh fixation during laparoscopic hernia repairs. Although manufacturers recommend deploying tacks perpendicular to the tissue, achieving this can sometimes be challenging. This study aimed to analyze comparatively the effects of angled deployment among commonly used tacks. METHODS: A piece of composite mesh was fixed to the peritoneal surface of a pig with a single tack fired at either a perpendicular (90°) or acute (30°) angle. A lap-shear test was performed to determine fixation strength. Two permanent tacks (a titanium spiral tack: Protack [PT]; and a hollow screw fastener: PermaFix [PF]) and three absorbable tackers (a solid screw: Absorbatack [AT]; a hollow screw fastener: SorbaFix [SF]; and a strap: SecurStrap [SS]) were challenged. A total of 16 samples were performed for each device at each angle. A nonabsorbable transfascial suture was used as a control condition. RESULTS: Transabdominal sutures had the maximum acute tensile strength (ATS) (29.9 ± 5.5 N). Protack at both 90° and 30° performed significantly better than absorbable tacks (p < 0.01). No significant difference was found among absorbable tacks at 90°. When the same construct was compared at different angles, SS and SF performance was not affected (p = 0.07 and 0.2, respectively). In contrast, PT and AT had significantly reduced fixation strength (p = 0.003 and 0.004, respectively). However, PT fired at an acute angle had fixation equal to that of absorbable tacks fired perpendicularly. CONCLUSION: Transabdominal sutures performed better than tacks in the acute setting. No absorbable fixation device demonstrated superior efficacy within its class. Spiral titanium tacks provided better fixation than absorbable tacks at both perpendicular and acute angles. Moreover, titanium spiral tacks deployed at 30° performed equal to or better than absorbable tacks fired perpendicularly to the tissue. It appears that spiral titanium tacks should be strongly considered for cases in which perpendicular tack deployment cannot be achieved.
Authors:
Emmanuel E Sadava; David M Krpata; Yue Gao; Steve Schomisch; Michael J Rosen; Yuri W Novitsky
Related Documents :
23152788 - Mineral distributions at the developing tendon enthesis.
22100348 - A functionalizable polymer designed for bone tissue engineering.
23044938 - Neuropeptide y is a critical modulator of leptin's regulation of cortical bone.
6398058 - Modified autosuture technique for ileal conduit construction in urinary diversion.
18465138 - Operative treatment of tibial shaft fractures: a comparison of different methods of pri...
11553228 - Successful primary reinforced repair of esophageal perforation using a pedicled omental...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-9
Journal Detail:
Title:  Surgical endoscopy     Volume:  -     ISSN:  1432-2218     ISO Abbreviation:  Surg Endosc     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-9     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8806653     Medline TA:  Surg Endosc     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Case Comprehensive Hernia Center, University Hospitals Case Medical Center, 11100 Euclid Avenue, Cleveland, OH, 44106-5047, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Enteral stenting versus gastrojejunostomy for palliation of malignant gastric outlet obstruction.
Next Document:  What influence does intermittent pneumatic compression of the lower limbs intraoperatively have on c...