BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring cardiac output (CO) during steady state and with induced haemodynamic changes in patients scheduled for elective cardiac surgery. METHODS: Twenty-five patients were enrolled. After induction of anaesthesia, endotracheal intubation using a dedicated ECOM tube, and insertion of the pulmonary artery catheter (PAC), the patient was placed in the following successive positions: (a) supine, (b) head-down tilt, (c) head-up tilt, (d) supine, (e) supine with phenylephrine administration. CO was measured simultaneously using the ECOM and the PAC. RESULTS: Both methods showed an equally good precision < 10%. Compared to PAC TD, the ECOM system was associated with a bias in supine position of -0.45 l/min (95% confidence interval: -0.86; -0.05), limits of agreement -2.40 l/min to 1.49 l/min and a percentage error of 41.0%. There was no agreement in trending ability between the two methods, with a concordance rate of 30%, shown in a four-quadrant plot. CONCLUSION: In a direct comparison with PAC TD, the ECOM system did not show an acceptable agreement, with wide limits of agreement, a much larger percentage error than should be expected from the precision of the two methods and a very poor trending ability. Thus, the ECOM does not replace measurements done by thermodilution using a pulmonary artery catheter in cardiac surgery patients.
H Møller-Sørensen; K L Hansen; M Ostergaard; L W Andersen; K Møller
Related Documents :
16159836 - Hemodynamic and vascular effects of ventricular sourcing by stent-based ventricle to co...
22032596 - Intrinsic flaps in the hand.
3644586 - Granulocytes in bronchial lavage fluid after major vascular surgery.
941896 - Pulmonary function studies before and after jejunoileal bypass surgery.
19187856 - Echocardiographic evolution of prosthetic aortic valve endocarditis with aorto-left atr...
23337996 - Bilaterally absent posterior inferior cerebellar artery: case report.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-23
Journal Detail:
Title:  Acta anaesthesiologica Scandinavica     Volume:  -     ISSN:  1399-6576     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0370270     Medline TA:  Acta Anaesthesiol Scand     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
© 2011 The Authors Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.
Department of Cardiothoracic Anesthesia, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Seasonal variation in the hip score of dogs as assessed by the New Zealand Veterinary Association Hi...
Next Document:  The inter-rater and intra-rater reliability of a modified "severity scale for assessment of plagioce...