Document Detail


Investigation of organic vapor losses to condensed water vapor in Tedlar bags used for exhaled-breath sampling.
MedLine Citation:
PMID:  8776196     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This study evaluated the potential loss of organic vapors to condensed water in bags used for breath sampling. "Wet" test atmospheres were prepared by transferring nitrogen into 1-L Tedlar bags and spiking with water and each of several organic solvents (methanol, acetone, 2-butanone,m-xylene, 1,1,1 trichloroethane, and perchloroethylene) to yield atmospheres representative of a 500-mL breath sample collected at 37 degrees C and cooled to 25 degrees C. Vapor concentrations were compared with those in bags prepared without water. Differences between mean concentrations in wet and dry bags were significant only for methanol, which yielded a mean wet-bag concentration approximately 10% lower than for dry bags. In a second series of experiments the same initial concentration of solvent vapor was generated in 1 dry bag and 5 bags containing 1 to 20 times the amount of water expected to condense in a 500-mL breath sample. Significant differences between wet and dry bag concentrations were seen for methanol, acetone, and 2-butanone; however, the quantity of water required to produce this difference in the acetone and 2-butanone bags exceeded three times that expected to condense in a breath sample. Results were in good agreement with predictions based on Henry's law. In both experiments permeation of water vapor out of the bags led to a decrease in the quantity of condensed water, thereby reducing the extent of organic vapor partitioning. These results indicate that solvent vapor loss to condensed water is not likely to be significant under typical conditions.
Authors:
W A Groves; E T Zellers
Related Documents :
18036656 - Xrd studies of beta-chitin from squid pen with calcium solvent.
21405056 - Synthesis, self-assembly, and photophysical properties of cationic oligo(p-phenyleneeth...
14640726 - Solvent compatibility of poly(dimethylsiloxane)-based microfluidic devices.
22272776 - Interfacial assembly of a series of cinnamoyl-containing bolaamphiphiles: spacer contro...
16904736 - Effects of aqueous aluminium on four fish ectoparasites.
16771306 - Solution-based growth and optical properties of self-assembled monocrystalline zno elli...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  American Industrial Hygiene Association journal     Volume:  57     ISSN:  0002-8894     ISO Abbreviation:  Am Ind Hyg Assoc J     Publication Date:  1996 Mar 
Date Detail:
Created Date:  1996-12-03     Completed Date:  1996-12-03     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0371160     Medline TA:  Am Ind Hyg Assoc J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  257-63     Citation Subset:  IM    
Affiliation:
Department of Environmental and Industrial Health, University of Michigan, Ann Arbor 48109-2029, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Body Water*
Breath Tests*
Humans
Solvents
Volatilization
Chemical
Reg. No./Substance:
0/Solvents

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An experimental design approach to retrospective exposure assessment.
Next Document:  Evaluation of muff-type hearing protectors as used in a working environment.