Document Detail


Investigation of the Suitability of Tissue Phantoms for Testing the Constancy of Ultrasonic Transducer Arrays in Quality Assurance.
MedLine Citation:
PMID:  22576698     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Purpose: To ensure high quality ultrasound diagnostics, proper functioning of the devices used is a necessary prerequisite. Ultrasound transducers have proven to be the most failure-prone part of the signal chain. Their technical monitoring is possible in principle with the help of tissue phantoms. The background of the present study is to determine which type of phantoms and which measurement parameters are best suited to a consistency test as part of routine quality assurance of ultrasound imaging systems. Materials and Methods: A classic wire-type phantom (ATS Mod. 539, ATS Labs Bridgeport, USA) and a 3 D cyst phantom (TCC, Timelkam, Austria) were used for the studies and comparative tests were conducted between intact transducers and those in which faults had been simulated. The collected measurement data show a relatively large scatter. Therefore, statistical analysis methods were used, and the discrimination analysis proved to be a useful tool. Results: Local failures which arise, e. g. due to the breakdown of individual piezoelectric elements or element groups in the transducer array, can be detected with the help of the gray value targets of the ATS phantom, but only in those cases in which the error-affected sound field part actually overlaps with the target under consideration. The TCC phantom is not suitable for the detection of such errors. Global transducer failures, i. e. those that affect the entire array, can even be detected with both types of phantoms. Conclusion: When the emphasis of quality assessment is on the detection of local defects in the array that make up the largest part of the transducer faults, studies with conventional phantoms are only of limited value.
Authors:
E Rosenfeld; S Wolter; A Kopp; E Liebscher
Related Documents :
20383988 - Radiographic anatomy of the articular process joints of the caudal cervical vertebrae i...
16808568 - Validity and reliability of a new edge-based computerized method for identification of ...
10371308 - Digital imaging in the assessment of facial deformity.
12148738 - Development of a computerized method for identifying the posteroanterior and lateral vi...
7283368 - A computer-based laboratory record system in an endocrinology laboratory.
21869108 - Three-dimensional digital line segments.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-5-10
Journal Detail:
Title:  Ultraschall in der Medizin (Stuttgart, Germany : 1980)     Volume:  -     ISSN:  1438-8782     ISO Abbreviation:  -     Publication Date:  2012 May 
Date Detail:
Created Date:  2012-5-11     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8303585     Medline TA:  Ultraschall Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
© Georg Thieme Verlag KG Stuttgart · New York.
Affiliation:
FB Ingenieur- und Naturwissenschaften, Hochschule Merseburg.
Vernacular Title:
Untersuchungen zur Eignung von Gewebephantomen für die Konstanzprüfung von Ultraschall-Wandlerarrays im Rahmen einer Qualitätssicherung.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pixelwise Quantification of Placental Perfusion Visualized by 3D Power Doppler Sonography.
Next Document:  Enhanced antitumor effect of cisplatin in human NSCLC cells by tumor suppressor LKB1.