Abstract/OtherAbstract:
A 63-year-old man had undergone graft replacement of the descending aorta due to dissection of aortic aneurysm nine years before and closure of an aortobronchopulmonary fistula two years before. He was admitted to our hospital because of massive hemoptysis. Angiography and chest computed tomography (CT) revealed a pseudoaneurysm on the proximal end caused by graft detachment. Intravascular ultrasound clearly revealed half round detachment on both ends of the graft. Replacement of the ascending, arch and distal aorta including the graft was performed, and the patient's postoperative course has been satisfactory. We have concluded that intravascular ultrasound is a useful method for detecting pseudoaneurysm after graft replacement which is not evident on cineangiography, CT or distal subtraction angiography.
Authors:
Takeshiro Fujii; Yoshinori Watanabe; Noritsugu Shiono; Muneyasu Kawasaki; Katsunori Yoshihara; Nobuya Koyama
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyōbu Geka Gakkai zasshi     Volume:  52     ISSN:  1344-4964     ISO Abbreviation:  Jpn. J. Thorac. Cardiovasc. Surg.     Publication Date:  2004 Apr 
Date Detail:
Created Date:  2004-05-14     Completed Date:  2004-06-29     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  100884261     Medline TA:  Jpn J Thorac Cardiovasc Surg     Country:  Japan    
Other Details:
Languages:  eng     Pagination:  205-8     Citation Subset:  IM    
Affiliation:
Division of Cardiovascular Surgery, Department of Surgery, Toho University School of Medicine, 6-11-1 Omorinishi, Ota-ku, Tokyo 143-8541, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aneurysm, Dissecting / complications,  surgery
Aneurysm, False / etiology,  ultrasonography*
Aorta, Thoracic / surgery*
Aortic Aneurysm / complications,  surgery
Aortic Diseases / etiology*,  surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation*
Bronchial Fistula / etiology*,  surgery
Fistula / etiology*,  surgery
Humans
Lung Diseases / etiology*,  surgery
Male
Middle Aged
Prosthesis Failure
Reoperation
Ultrasonography, Interventional / methods*
Vascular Fistula / etiology*,  surgery